Searcharxiv⌕ Search

arXiv subjects

H. Y. Ngai

Publications and source records attributed to H. Y. Ngai.

3 recordsLinked to original sources

Measurement of Cosmic-ray Muons and Muon-induced Neutrons in the Aberdeen Tunnel Underground Laboratory

We have measured the muon flux and production rate of muon-induced neutrons at a depth of 611 m water equivalent. Our apparatus comprises three layers of crossed plastic scintillator hodoscopes for tracking the incident cosmic-ray muons and 760 L of gadolinium-doped liquid scintillator for producing and detecting neutrons. The vertical muon intensity was measured to be $I_μ = (5.7 \pm 0.6) \times 10^{-6}$ cm$^{-2}$s$^{-1}$sr$^{-1}$. The yield of muon-induced neutrons in the liquid scintillator was determined to be $Y_{n} = (1.19 \pm 0.08 (stat) \pm 0.21 (syst)) \times 10^{-4}$ neutrons/($μ\cdot$g$\cdot$cm$^{-2}$). A fit to the recently measured neutron yields at different depths gave a mean muon energy dependence of $\left\langle E_μ \right\rangle^{0.76 \pm 0.03}$ for liquid-scintillator targets.

physics.ins-det↗

Development of a Bonner Sphere Neutron Spectrometer from a Commercial Neutron Dosimeter

Bonner Spheres have been used widely for the measurement of neutron spectra with neutron energies ranged from thermal up to at least 20 MeV. A Bonner Sphere neutron spectrometer (BSS) was developed by extending a Berthold LB 6411 neutron-dose-rate meter. The BSS consists of a $^{3}$He thermal-neutron detector with integrated electronics, a set of eight polyethylene spherical shells and two optional lead shells of various sizes. The response matrix of the BSS was calculated with GEANT4 Monte Carlo simulation. The BSS had a calibration uncertainty of $\pm 8.6\%$ and a detector background rate of $(1.57 \pm 0.04) \times 10^{-3}$ s$^{-1}$. A spectral unfolding code NSUGA was developed. The NSUGA code utilizes genetic algorithms and has been shown to perform well in the absence of a priori information.

physics.ins-det↗

An apparatus for studying spallation neutrons in the Aberdeen Tunnel laboratory

In this paper, we describe the design, construction and performance of an apparatus installed in the Aberdeen Tunnel laboratory in Hong Kong for studying spallation neutrons induced by cosmic-ray muons under a vertical rock overburden of 611 meter water equivalent (m.w.e.). The apparatus comprises of six horizontal layers of plastic-scintillator hodoscopes for determining the direction and position of the incident cosmic-ray muons. Sandwiched between the hodoscope planes is a neutron detector filled with 650 kg of liquid scintillator doped with about 0.06% of Gadolinium by weight for improving the efficiency of detecting the spallation neutrons. Performance of the apparatus is also presented.

physics.ins-det↗