Ultra-thin corrugated metamaterial film as large-area transmission dynode

Large-area transmission dynodes were fabricated by depositing an ultra-thin continuous film on a silicon wafer with a 3-dimensional pattern. After removing the silicon, a corrugated membrane with enhanced mechanical properties was formed. Mechanical materials, such as this corrugated membrane, are engineered to improve its strength and robustness, which allows it to span a larger surface in comparison to flat membranes while the film thickness remains constant. The ultra-thin film consists of three layers (Al$_2$O$_3$ /TiN/Al$_2$O$_3$) and is deposited by atomic layer deposition (ALD). The encapsulated TiN layer provides in-plane conductivity, which is needed to sustain secondary electron emission. Two types of corrugated membranes were fabricated: a hexagonal honeycomb and an octagonal pattern. The latter was designed to match the square pitch of a CMOS pixel chip. The transmission secondary electron yield was determined with a collector-based method using a scanning electron microscope. The highest transmission electron yield was measured on a membrane with an octagonal pattern. A yield of 2.15 was achieved for 3.15 keV incident electrons for an Al$_2$O$_3$ /TiN/Al$_2$O$_3$ tri-layer film with layer thicknesses of 10/5/15 nm. The variation in yield across the surface of the corrugated membrane was determined by constructing a yield map. The active surface for transmission secondary electron emission is near 100%, i.e. a primary electron generates transmission secondary electrons regardless of the point of impact on the corrugated membrane.

physics.ins-det

Measurement of the transmission secondary electron yield of nanometer-thick films in a prototype Timed Photon Counter

We measure the transmission secondary electron yield of nanometer-thick Al$_2$O$_3$/TiN/Al$_2$O$_3$ films using a prototype version of a Timed Photon Counter (TiPC). We discuss the method to measure the yield extensively. The yield is then measured as a function of landing energy between $1.2$ and $1.8$ keV and found to be in the range of $0.1$ ($1.2$ keV) to $0.9$ ($1.8$ keV). These results are in agreement to data obtained by a different, independent method. We therefore conclude that the prototype TiPC is able to characterise the thin films in terms of transmission secondary electron yield. Additionally, observed features which are unrelated to the yield determination are interpreted.

physics.ins-det

Performance of a GridPix TPC readout based on the Timepix3 chip

With the ultimate goal of developing a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the readout plane is dominated by diffusion. Systematic uncertainties are limited to below 10 $μ$m. The GridPix can detect single ionization electrons with high efficiency, which allows for energy loss measurements and particle identification. From a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m. Using the same type of chips, a Quad module was developed that can be tiled to cover a TPC readout plane at the ILC. Simulation studies show that a pixel readout can improve the momentum resolution of a TPC at the ILC by about 20%.

physics.ins-det

Performance of a GridPix detector based on the Timepix3 chip

A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix3 chip allowed for high sample rates and time walk corrections. Diffusion is found to be the dominating error on the track position measurement both in the pixel plane and in the drift direction, and systematic distortions in the pixel plane are below 10 $μ$m. Using a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m.

physics.ins-det

The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit

A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.

physics.ins-det

Measurement of mechanical vibrations excited in aluminium resonators by 0.6 GeV electrons

We present measurements of mechanical vibrations induced by 0.6 GeV electrons impinging on cylindrical and spherical aluminium resonators. To monitor the amplitude of the resonator's vibrational modes we used piezoelectric ceramic sensors, calibrated by standard accelerometers. Calculations using the thermo-acoustic conversion model, agree well with the experimental data, as demonstrated by the specific variation of the excitation strengths with the absorbed energy, and with the traversing particles' track positions. For the first longitudinal mode of the cylindrical resonator we measured a conversion factor of 7.4 +- 1.4 nm/J, confirming the model value of 10 nm/J. Also, for the spherical resonator, we found the model values for the L=2 and L=1 mode amplitudes to be consistent with our measurement. We thus have confirmed the applicability of the model, and we note that calculations based on the model have shown that next generation resonant mass gravitational wave detectors can only be expected to reach their intended ultra high sensitivity if they will be shielded by an appreciable amount of rock, where a veto detector can reduce the background of remaining impinging cosmic rays effectively.

physics.ins-det