Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System

The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector is employed to monitor the temporal evolution of radon activity. To determine the radon reduction factor, the experimental data of radon atoms introduced into and bypassed the distillation system is compared. The results indicate that the PandaX-4T distillation system achieves a radon reduction factor exceeding 190 at the flow rate of 10 slpm and the reflux ratio of 1.44. Gas-only online distillation process of a flow rate of 20 slpm is also conducted without observing significant reduction of radon levels in the detector. This observation suggests that the migration flow of radon atoms from the liquid phase to the gas phase is limited, and the flow rate of gas circulation and duration of the process are insignificant compared to the total xenon mass of 5.6 tons in the detector. This study provides the experimental data to support the efficient removal of radon at $\sim$Bq level using the PandaX-4T distillation system, which is the prerequisite of the radon background control in the detector. The further operation with higher flow rate will be applied for the upcoming science run in PandaX-4T.

physics.ins-det

Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the concentration of krypton in commercial xenon from 5X$10^{-7}$ mol/mol to $10^{-14}$ mol/mol with 99% xenon collection efficiency at a maximum flow rate of 10 kg/h. The offline distillation operation has been completed and 5.75 tons of ultra-high purity xenon was produced, which is used as the detection medium in PandaX-4T detector. The krypton concentration of the product xenon is measured with an upper limit of 8.0 ppt. The stability and purification performance of the cryogenic distillation system are studied by analyzing the experimental data, which is important for theoretical research and distillation operation optimization.

physics.ins-det

Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is expected to be reduced by 7 orders of magnitude with 99% xenon collection efficiency at a flow rate of 10 kg/h by design. The same system can reduce radon content in xenon by reversed operation, with an expected radon reduction factor of about 1.8 in PandaX-4T under a flow rate of 56.5 kg/h. The commissioning of this system was completed, with krypton and radon operations tested under respective working conditions. The krypton concentration of the product xenon was measured with an upper limit of 8.0 ppt.

physics.ins-det