Searcharxiv⌕ Search

arXiv subjects

Haixing Miao

Publications and source records attributed to Haixing Miao.

At least 55 records · Page 3Linked to original sources

Quantum Squeezing Schemes for Heterodyne Readout

Advanced gravitational-wave detectors are limited by quantum noise in their most sensitive frequency band. Quantum noise suppression techniques, such as the application of the quantum squeezed state of light, have been actively studied in the context of homodyne readouts. In this paper, we consider quantum squeezing schemes for the heterodyne readouts. This is motivated by a successful suppression of the higher-order-mode content by stable recycling cavities in advanced detectors. The heterodyne readout scheme requires precise tuning of the interferometer parameters and a broadband squeezing source, but is conceptually simple and elegant. We further show that it is compatible with the frequency-dependent squeezing, which reduces both the shot noise and the radiation-pressure noise. We propose a test of the heterodyne readout with squeezing in Advanced LIGO. This can serve as a pathfinder not only for the implementation in future detectors, such as Einstein Telescope and Cosmic Explorer, but also for general high-precision optical measurements.

gr-qc↗

Implications of the Quantum Noise Target for the Einstein Telescope Infrastructure Design

The design of a complex instrument such as Einstein Telescope (ET) is based on a target sensitivity derived from an elaborate case for scientific exploration. At the same time it incorporates many trade-off decisions to maximise the scientific value by balancing the performance of the various subsystems against the cost of the installation and operation. In this paper we discuss the impact of a long signal recycling cavity (SRC) on the quantum noise performance. We show the reduction in sensitivity due to a long SRC for an ET high-frequency interferometer, provide details on possible compensations schemes and suggest a reduction of the SRC length. We also recall details of the trade-off between the length and optical losses for filter cavities, and show the strict requirements for an ET low-frequency interferometer. Finally, we present an alternative filter cavity design for an ET low-frequency interferometer making use of a coupled cavity, and discuss the advantages of the design in this context.

astro-ph.IM↗

Quantum correlation of light mediated by gravity

We propose to explore the quantum nature of gravity using the correlation of light between two optomechanical cavities, and the quantumness of the correlation is witnessed by squeezing. As long as the gravity between the end mirrors of two cavities is quantum in the Newtonian limit, we show that the squeezing is always nonzero and monotonically increases as the mechanical property of the mirrors is improved. The proposed scheme provides a new pathway for testing the quantum nature of gravity systematically with tabletop experiments.

quant-ph↗

Application of optomechanical frequency conversion on gravitational wave detection

Optomechanical interaction can be a platform for converting quantum optical sates at different frequencies. In this work, we propose to combine the idea of optomechanical frequency conversion and the dual-use of laser interferometer, for the purpose of improving the broadband sensitivity of laser interferometer gravitational wave detectors by filtering the light field. We found that compare to the previous schemes of implementing the optomechanical devices in gravitational wave detectors, this frequency converter scheme will have less stringent requirement on the thermal noise dilution.

quant-ph↗

Simplified optical configuration for a sloshing-speedmeter-enhanced gravitational wave detector

We propose a new optical configuration for an interferometric gravitational wave detector based on the speedmeter concept using a sloshing cavity. Speedmeters provide an inherently better quantum-noise limited sensitivity at low frequencies than the currently used Michelson interferometers. We show that a practical sloshing cavity can be added relatively simply to an existing dual-recycled Michelson interferometer such as Advanced LIGO.

gr-qc↗

Broadband Quantum Noise Reduction in Future Long Baseline Gravitational-wave Detectors via EPR Entanglement

Broadband quantum noise reduction can be achieved in gravitational wave detectors by injecting frequency dependent squeezed light into the the dark port of the interferometer. This frequency dependent squeezing can be generated by combining squeezed light with external filter cavities. However, in future long baseline interferometers (LBIs), the filter cavity required to achieve the broadband squeezing has a low bandwidth -- necessitating a very long cavity to mitigate the issue from optical loss. It has been shown recently that by taking advantage of Einstein-Podolsky-Rosen (EPR) entanglement in the squeezed light source, the interferometer can simultaneously act as a detector and a filter cavity. This is an attractive broadband squeezing scheme for LBIs because the length requirement for the filter cavity is naturally satisfied by the length of the interferometer arms. In this paper we present a systematic way of finding the working points for this broadband squeezing scheme in LBIs. We also show that in LBIs, the EPR scheme achieves nearly perfect ellipse rotation as compared to 4km interferometers which have appreciable error around the intermediate frequency. Finally, we show that an approximation for the opto-mechanical coupling constant in the 4km case can break down for longer baselines. These results are applicable to future detectors such as the 10km Einstein Telescope and the 40km Cosmic Explorer.

quant-ph↗

Advanced quantum techniques for future gravitational-wave detectors

Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article: "Quantum measurement theory in gravitational-wave detectors"' [Living Rev. Relativity 15, 5 (2012)], we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.

gr-qc↗

Converting the signal-recycling cavity into an unstable optomechanical filter to enhance the detection bandwidth of gravitational-wave detectors

Current and future interferometeric gravitational-wave detectors are limited predominantly by shot noise at high frequencies. Shot noise is reduced by introducing arm cavities and signal recycling, however, there exists a tradeoff between the peak sensitivity and bandwidth. This comes from the accumulated phase of signal sidebands when propagating inside the arm cavities. One idea is to cancel such a phase by introducing an unstable optomechanical filter. The original design proposed in [Phys.~Rev.~Lett.~{\bf 115},~211104 (2015)] requires an additional optomechanical filter coupled externally to the main interferometer. Here we consider a simplified design that converts the signal-recycling cavity itself into the unstable filter by using one mirror as a high-frequency mechanical oscillator and introducing an additional pump laser. However, the enhancement in bandwidth of this new design is less than the original design given the same set of optical parameters. The peak sensitivity improvement factor depends on the arm length, the signal-recycling cavity length, and the final detector bandwidth. For a 4~km interferometer, if the final detector bandwidth is around 2~kHz, with a 20~m signal-recycling cavity, the shot noise can be reduced by 10 decibels, in addition to the improvement introduced by squeezed light injection. We also find that the thermal noise of the mechanical oscillator is enhanced at low frequencies relative to the vacuum noise, while having a flat spectrum at high frequencies.

astro-ph.IM↗

Quantum limit for laser interferometric gravitational wave detectors from optical dissipation

We derive a quantum limit to the sensitivity of laser interferometric gravitational-wave detectors from optical-loss-induced dissipation, analogous to the sensitivity limit from the mechanical dissipation. It applies universally to different interferometer configurations, and cannot be surpassed unless the optical property is improved. This result provides an answer to the long-standing question of how far we can push the detector sensitivity given the state-of-the-art optics.

quant-ph↗

Exploring the sensitivity of gravitational wave detectors to neutron star physics

The physics of neutron stars can be studied with gravitational waves emitted from coalescing binary systems. Tidal effects become significant during the last few orbits and can be visible in the gravitational-wave spectrum above 500 Hz. After the merger, the neutron star remnant oscillates at frequencies above 1 kHz and can collapse into a black hole. Gravitational-wave detectors with a sensitivity of ~10^{-24} strain/sqHz at 2-4 kHz can observe these oscillations from a source which is ~100 Mpc away. The current observatories, such as LIGO and Virgo, are limited by shot noise at high frequencies and have a sensitivity of > 2 * 10^{-23} strain/sqHz at 3 kHz. In this paper, we propose an optical configuration of gravitational-wave detectors which can be set up in present facilities using the current interferometer topology. This scheme has a potential to reach 7 * 10^{-25} strain/sqHz at 2.5 kHz without compromising the detector sensitivity to black hole binaries. We argue that the proposed instruments have a potential to detect similar amount of post-merger neutron star oscillations as the next generation detectors, such as Cosmic Explorer and Einstein Telescope. We also optimise the arm length of the future detectors for neutron star physics and find that the optimal arm length is ~20 km. These instruments have the potential to observe neutron star post-merger oscillations at a rate of ~30 events per year with a signal-to-noise ratio of 5 or more.

astro-ph.IM↗

Symmetry selective Dynamic Casimir Effect in One-Dimensional Photonic Crystals

Real photon pairs can be created in a dynamic cavity with periodically modulated refractive index of the constituent media or oscillating boundaries. This effect is called Dynamic Casimir effect (DCE), which represents one of the most amazing predictions of quantum field theory. Here, we investigate DCE in a dynamic one-dimensional photonic crystal system with both temporal and spatial modulation of the refractive index profile. Such a system can resonantly generate photons at driving frequencies equal to even or odd integer times of that of the fundamental cavity mode governed by the symmetry of the spatial modulation. We further observe interesting spectral and scaling behaviors for photons excited at the band edge. Our discovery introduces a new degree of freedom to enhance the efficiency of DCE.

physics.optics↗

Fundamental quantum limits of multi-carrier optomechanical sensors

Optomechanical sensors involving multiple optical carriers can experience mechanically mediated interactions causing multi-mode correlations across the optical fields. One instance is laser-interferometric gravitational wave detectors which introduce multiple carrier frequencies for classical sensing and control purposes. An outstanding question is whether such multi-carrier optomechanical sensors outperform their single-carrier counterpart in terms of quantum-limited sensitivity. We show that the best precision is achieved by a single-carrier instance of the sensor. For the current LIGO detection system this precision is already reachable.

quant-ph↗

Towards the Design of Gravitational-Wave Detectors for Probing Neutron-Star Physics

The gravitational waveform of merging binary neutron stars encodes information about extreme states of matter. Probing these gravitational emissions requires the gravitational-wave detectors to have high sensitivity above 1 kHz. Fortunately for current advanced detectors, there is a sizeable gap between the quantum-limited sensitivity and the classical noise at high frequencies. Here we propose a detector design that closes such a gap by reducing the high-frequency quantum noise with an active optomechanical filter, frequency-dependent squeezing, and high optical power. The resulting noise level from 1 kHz to 4 kHz approaches the current facility limit and is a factor of 20 to 30 below the design of existing advanced detectors. This will allow for precision measurements of (i) the post-merger signal of the binary neutron star, (ii) late-time inspiral, merger, and ringdown of low-mass black hole-neutron star systems, and possible detection of (iii) high-frequency modes during supernovae explosions. This design tries to maximize the science return of current facilities by achieving a sensitive frequency band that is complementary to the longer-baseline third-generation detectors: the10 km Einstein Telescope, and 40 km Cosmic Explorer. We have highlighted the main technical challenges towards realizing the design, which requires dedicated research programs. If demonstrated in current facilities, the techniques can be transferred to new facilities with longer baselines.

gr-qc↗

Fundamental Limitations of Cavity-assisted Atom Interferometry

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g-factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

physics.atom-ph↗

Broadband sensitivity enhancement of detuned dual-recycled Michelson interferometers with EPR entanglement

We demonstrate the applicability of the EPR entanglement squeezing scheme for enhancing the shot-noise-limited sensitivity of a detuned dual-recycled Michelson interferometers. In particular, this scheme is applied to the GEO\,600 interferometer. The effect of losses throughout the interferometer, arm length asymmetries, and imperfect separation of the signal and idler beams are considered.

quant-ph↗

Multi-spatial-mode effects in squeezed-light-enhanced interferometric gravitational wave detectors

Proposed near-future upgrades of the current advanced interferometric gravitational wave detectors include the usage of frequency dependent squeezed light to reduce the current sensitivity-limiting quantum noise. We quantify and describe the degradation effects that spatial mode-mismatches between optical resonators have on the squeezed field. These mode-mismatches can to first order be described by scattering of light into second-order Gaussian modes. As a demonstration of principle, we also show that squeezing the second-order Hermite-Gaussian modes $\mathrm{HG}_{02}$ and $\mathrm{HG}_{20}$, in addition to the fundamental mode, has the potential to increase the robustness to spatial mode-mismatches. This scheme, however, requires independently optimized squeeze angles for each squeezed spatial mode, which would be challenging to realise in practise.

physics.optics↗

Towards the Fundamental Quantum Limit of Linear Measurements of Classical Signals

The quantum Cramér-Rao bound (QCRB) sets a fundamental limit for the measurement of classical signals with detectors operating in the quantum regime. Using linear-response theory and the Heisenberg uncertainty relation, we derive a general condition for achieving such a fundamental limit. When applied to classical displacement measurements with a test mass, this condition leads to an explicit connection between the QCRB and the Standard Quantum Limit which arises from a tradeoff between the measurement imprecision and quantum backaction; the QCRB can be viewed as an outcome of a quantum non-demolition measurement with the backaction evaded. Additionally, we show that the test mass is more a resource for improving measurement sensitivity than a victim of the quantum backaction, which suggests a new approach to enhancing the sensitivity of a broad class of sensors. We illustrate these points with laser interferometric gravitational wave detectors.

quant-ph↗

Beating the standard sensitivity-bandwidth limit of cavity-enhanced interferometers with internal squeezed-light generation

The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intra-cavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using non-classical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a non-classical correlation directly inside the interferometer cavity. We analyse the limits of the approach theoretically, and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.

quant-ph↗