SearcharxivSearch

arXiv subjects

Hajime Inaba

Publications and source records attributed to Hajime Inaba.

At least 19 recordsLinked to original sources

Broadband and flat-baseline dual-comb cavity mode dispersion spectroscopy using fiber-based frequency combs

We demonstrate broadband dual-comb cavity mode dispersion spectroscopy using mode-locked erbium-fiber frequency combs and a length-tunable optical cavity. The flat baseline and low-noise characteristics of cavity-mode-dispersion spectroscopy, combined with the broadband coverage of fiber frequency combs, provide highly precise spectral profiles that are difficult to obtain with conventional dual-comb spectroscopy. We measured the entire $\nu_1 + \nu_3$ band of acetylene in the $1.5~\mathrm{\mu m}$ region. The simultaneous fitting of multiple transitions agreed well with the measured spectra, yielding a relative standard deviation of 0.27 % for the retrieved acetylene pressure and a spectral fluctuation corresponding to an absorption coefficient of $1.4\times 10^{-6}~\mathrm{cm}^{-1}$. These results reveal the high precision achievable with the present method. Further sensitivity improvements are expected with a higher-finesse cavity.

physics.optics

Optical sound pressure measurement using Fabry-P\'erot cavity for primary acoustic standards

Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry-P\'erot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air's refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 dB and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.

physics.ins-det

Improved absolute frequency measurement of $^{171}$Yb at NMIJ with uncertainty below $2\times10^{-16}$

We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of $1.9\times10^{-16}$, in good agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of $^{171}$Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.

physics.atom-ph

Measurement of transition frequencies and hyperfine constants of molecular iodine at 520.2 nm

We measured the transition frequencies of the hyperfine components in the four lines (P(34) 39-0, R(36) 39-0, P(33) 39-0, and R(35) 39-0) of the B-X transitions of molecular iodine at 520.2 nm. The 520.2 nm laser was generated by wavelength-converting the output of a 1560.6 nm external-cavity diode laser using a dual-pitch periodically poled lithium niobate (PPLN) waveguide. The frequencies were measured by counting the heterodyne beats between the laser stabilized at the frequencies of the hyperfine components and a frequency comb synchronized with a hydrogen maser. We determined the transition frequencies of the a1 components with relative uncertainties of 1*10-11; the uncertainty was limited by the impurity of the molecular iodine in the cell. From the measured hyperfine splitting frequencies, we calculated the hyperfine constants of these four transitions to obtain the rotational dependence of the excited-state hyperfine constants.

physics.chem-ph

Generation of a precise time scale assisted by a near-continuously operating optical lattice clock

We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.

physics.atom-ph

Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks

We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from $10^{-22}$ eV/$c^{2}$ to $10^{-20}$ eV/$c^{2}$ are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the $^{171}$Yb clock transition is also determined as $518\,295\,836\,590\,863.69(28)$ Hz, which is one of the important contributions towards a redefinition of the SI second.

physics.atom-ph

Erbium-doped-fiber-based broad visible range frequency comb with a 30 GHz mode spacing for astronomical applications

Optical frequency combs have the potential to improve the precision of the radial velocity measurement of celestial bodies, leading to breakthroughs in such fields as exoplanet exploration. For these purposes, the comb must have a broad spectral coverage in the visible wavelength region, a wide mode spacing that can be resolved with a high dispersion spectrograph, and sufficient robustness to operate for long periods even in remote locations. We have realized a comb system with a 30 GHz mode spacing, 62 % available wavelength coverage in the visible region, and 40 dB spectral contrast by combining a robust erbium-doped-fiber-based femtosecond laser, mode filtering with newly designed optical cavities, and broadband-visible-range comb generation using a chirped periodically-poled LiNbO3 ridge waveguide. The system durability and reliability are also promising because of the stable spectrum, which is due to the use of almost all polarization-maintaining fiber optics, moderate optical power, and good frequency repeatability obtained with a wavelength-stabilized laser.

astro-ph.IM

Ultra-precise determination of thicknesses and refractive indices of optically thick dispersive materials by dual-comb spectroscopy

Precise measurements of the geometrical thickness of a sample and its refractive index are important for materials science, engineering, and medical diagnosis. Among the possible non-contact evaluation methods, optical interferometric techniques possess the potential of providing superior resolution. However, in the optical frequency region, the ambiguity in the absolute phase-shift makes it difficult to measure these parameters of optically thick dispersive materials with sufficient resolution. Here, we demonstrate that dual frequency-comb spectroscopy can be used to precisely determine the absolute sample-induced phase-shift by analyzing the data smoothness. This method enables simultaneous determination of the geometrical thickness and the refractive index of a planar sample with a precision of five and a half digits and an ultra-wide dynamic range. The thickness and the refractive index at 193.414 THz of a silicon wafer determined by this method are 0.52047(3) mm and 3.4756(3), respectively, without any prior knowledge of the refractive index.

physics.optics

Demonstration of the nearly continuous operation of an $^{171}$Yb optical lattice clock for half a year

Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical lattice clocks has not yet reached a level comparable to that of Cs fountain clocks which contribute to International Atomic Time (TAI) by the nearly continuous operation. In this paper, we report the long-term operation of an $^{171}$Yb optical lattice clock with a coverage of 80.3% for half a year including uptimes of 93.9% for the first 24 days and 92.6% for the last 35 days. This enables a nearly dead-time-free frequency comparison of the optical lattice clock with TAI over months, which provides a link to the SI second with an uncertainty of low $10^{-16}$. By using this link, the absolute frequency of the $^{1}$S$_{0}-^{3}$P$_{0}$ clock transition of $^{171}$Yb is measured as 518 295 836 590 863.54(26) Hz with a fractional uncertainty of $5.0\times10^{-16}$. This value is in agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second.

physics.atom-ph

Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ

We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of $1.1\times10^{-16}$. We employed a $^{171}$Yb optical lattice clock with an uncertainty of $4\times10^{-16}$ that was developed for contributing to International Atomic Time (TAI). The measurement result is $\nu_{\mathrm{Yb}}/\nu_{\mathrm{Sr}}$ = 1.207 507 039 343 338 58(49)$_{\mathrm{sys}}$(6)$_{\mathrm{stat}}$ with a fractional uncertainty of $4.1\times10^{-16}$, which is 3.4 times smaller than our previous measurement result.

physics.atom-ph

Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ

We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrm{\mu}$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

physics.atom-ph

A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp

We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $\tau = 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the ${\rm {^1}S_{0} - {^1}P_{1}}$ transition in $^{174}\mathrm{Yb}$ was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.

physics.atom-ph

Dual-optical-comb spectroscopic ellipsometry

Spectroscopic ellipsometry is a means to investigate optical and dielectric material responses. Conventional spectroscopic ellipsometry has trade-offs between spectral accuracy, resolution, and measurement time. Polarization modulation has afforded poor performance due to its sensitivity to mechanical vibrational noise, thermal instability, and polarization wavelength dependency. We equip a spectroscopic ellipsometer with dual-optical-comb spectroscopy, viz. dual-optical-comb spectroscopic ellipsometry (DCSE). The DCSE directly and simultaneously obtains amplitude and phase information with ultra-high spectral precision that is beyond the conventional limit. This precision is due to the automatic time-sweeping acquisition of the interferogram using Fourier transform spectroscopy and optical combs with well-defined frequency. Ellipsometric evaluation without polarization modulation also enhances the stability and robustness of the system. In this study, we evaluate the DCSE of birefringent materials and thin films, which showed improved spectral accuracy and a resolution of up to 1.2x10-5 nm across a 5-10 THz spectral bandwidth without any mechanical movement.

physics.ins-det

Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm

We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.

physics.atom-ph

Improved frequency measurement of the $^1S_{0}$-$^3P_{0}$ clock transition in $^{87}$Sr using the Cs fountain clock at NMIJ as a transfer oscillator

We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.

physics.atom-ph

Ultra-broadband dual-comb spectroscopy across 1.0-1.9 μm

We have carried out dual-comb spectroscopy and observed in a simultaneous acquisition a 140-THz-wide spectrum from 1.0 to 1.9 μm using two fiber-based frequency combs phase-locked to each other. This ultra-broad wavelength bandwidth is realized by setting the difference between the repetition rates of the two combs to 7.6 Hz using the sub-Hz-linewidth fiber combs. The recorded spectrum contains five vibration-rotation bands of C${_2}$H${_2}$, CH${_4}$, and H${_2}$O at different wavelengths across the whole spectrum. The determined transition frequencies of C${_2}$H${_2}$ agree with those from the previous sub-Doppler resolution measurement of individual lines using CW lasers within 2 MHz.

physics.optics

A compact iodine-laser operating at 531 nm with stability at the 10$^{-12}$ level and using a coin-sized laser module

We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves frequency stability at the 10$^{-12}$ level. The absolute frequency of the compact laser stabilized to the $a_{1}$ hyperfine component of the $R(36)32-0$ transition is determined as $564\,074\,632\,419(8)$ kHz with a relative uncertainty of $1.4\times10^{-11}$. The iodine-stabilized laser can be used for various applications including interferometric measurements.

physics.optics

Real-time absolute frequency measurement of continuous-wave terahertz wave based on dual terahertz combs of photocarriers with different frequency spacings

Real-time measurement of the absolute frequency of continuous-wave terahertz (CW-THz) waves is required for characterization and frequency calibration of practical CW-THz sources. We proposed a method for real-time monitoring of the absolute frequency of CW-THz waves involving temporally parallel, i.e., simultaneous, measurement of two pairs of beat frequencies and laser repetition frequencies based on dual THz combs of photocarriers (PC-THz combs) with different frequency spacings. To demonstrate the method, THz-comb-referenced spectrum analyzers were constructed with a dual configuration based on dual femtosecond lasers. Regardless of the presence or absence of frequency control in the PC-THz combs, a frequency precision of 10-11 was achieved at a measurement rate of 100 Hz. Furthermore, large fluctuation of the CW-THz frequencies, crossing several modes of the PC-THz combs, was correctly monitored in real time. The proposed method will be a powerful tool for the research and development of practical CW-THz sources, and other applications.

physics.optics