SearcharxivSearch

arXiv subjects

Hamish G. Brown

Publications and source records attributed to Hamish G. Brown.

8 recordsLinked to original sources

Differential phase contrast from electrons that cause inner shell ionization

Differential Phase Contrast (DPC) imaging, in which deviations in the bright field beam are in proportion to the electric field, has been extensively studied in the context of pure elastic scattering. Here we discuss differential phase contrast formed from core-loss scattered electrons, i.e. those that have caused inner shell ionization of atoms in the specimen, using a transition potential approach for which we study the number of final states needed for a converged calculation. In the phase object approximation, we show formally that differential phase contrast formed from core-loss scattered electrons is mainly a result of preservation of elastic contrast. Through simulation we demonstrate that whether the inelastic DPC images show element selective contrast depends on the spatial range of the ionization interaction, and specifically that when the energy loss is low the delocalisation can lead to contributions to the contrast from atoms other than that ionized. We further show that inelastic DPC images remain robustly interpretable to larger thicknesses than is the case for elastic DPC images, owing to the incoherence of the inelastic wavefields, though subtleties due to channelling remain. Lastly, we show that while a very high dose will be needed for sufficient counting statistics to discern differential phase contrast from core-loss scattered electrons, there is some enhancement of signal-to-noise ratio with thickness that makes inelastic DPC imaging more achievable for thicker samples.

cond-mat.other

Improved Three-Dimensional Reconstructions in Electron Ptychography through Defocus Series Measurements

A detailed analysis of ptychography for 3D phase reconstructions of thick specimens is performed. We introduce multi-focus ptychography, which incorporates a 4D-STEM defocus series to enhance the quality of 3D reconstructions along the beam direction through a higher overdetermination ratio. This method is compared with established multi-slice ptychography techniques, such as conventional ptychography, regularized ptychography, and multi-mode ptychography. Additionally, we contrast multi-focus ptychography with an alternative method that uses virtual optical sectioning through a reconstructed scattering matrix ($\mathcal{S}$-matrix), which offers more precise 3D structure information compared to conventional ptychography. Our findings from multiple 3D reconstructions based on simulated and experimental data demonstrate that multi-focus ptychography surpasses other techniques, particularly in accurately reconstructing the surfaces and interface regions of thick specimens.

physics.optics

The 4D Camera: an 87 kHz direct electron detector for scanning/transmission electron microscopy

We describe the development, operation, and application of the 4D Camera -- a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at approximately 480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10 - 700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 - 300 keV. Through electron counting, the resulting sparse data sets are reduced in size by 10 - 300x compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex 4D-STEM experiments to be accomplished with typical STEM scanning parameters.

physics.ins-det

Fast unified reconstruction algorithm for conventional, phase-contrast and diffraction tomography

A unified method for three-dimensional reconstruction of objects from transmission images collected at multiple illumination directions is described. The method may be applicable to experimental conditions relevant to absorption-based, phase-contrast or diffraction imaging using X-rays, electrons and other forms of penetrating radiation or matter waves. Both the phase retrieval (also known as contrast transfer function correction) and the effect of Ewald sphere curvature (in the cases with a shallow depth of field and significant in-object diffraction) are incorporated in the proposed algorithm and can be taken into account. Multiple scattering is not treated explicitly, but can be mitigated as a result of angular averaging that constitutes an essential feature of the method. The corresponding numerical algorithm is based on three-dimensional gridding which allows for fast computational implementation, including a straightforward parallelization. The algorithm can be used with any scanning geometry involving plane-wave illumination. A software code implementing the proposed algorithm has been developed, tested on simulated and experimental image data and made publicly available.

physics.med-ph

A single-projection three-dimensional reconstruction algorithm for scanning transmission electron microscopy data

Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, Pb$_2$Ir$_2$O$_7$, and yttrium-stabilized zirconia,Y$_{0.095}$Zr$_{0.905}$O$_2$ , heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb-Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.

cond-mat.mtrl-sci

Strain fields in twisted bilayer graphene

Van der Waals heteroepitaxy allows deterministic control over lattice mismatch or azimuthal orientation between atomic layers to produce long wavelength superlattices. The resulting electronic phases depend critically on the superlattice periodicity as well as localized structural deformations that introduce disorder and strain. Here, we introduce Bragg interferometry, based on four-dimensional scanning transmission electron microscopy, to capture atomic displacement fields in twisted bilayer graphene with twist angles < 2°. Nanoscale spatial fluctuations in twist angle and uniaxial heterostrain are statistically evaluated, revealing the prevalence of short-range disorder in this class of materials. By quantitatively mapping strain tensor fields we uncover two distinct regimes of structural relaxation -- in contrast to previous models depicting a single continuous process -- and we disentangle the electronic contributions of the rotation modes that comprise this relaxation. Further, we find that applied heterostrain accumulates anisotropically in saddle point regions to generate distinctive striped shear strain phases. Our results thus establish the reconstruction mechanics underpinning the twist angle dependent electronic behaviour of twisted bilayer graphene, and provide a new framework for directly visualizing structural relaxation, disorder, and strain in any moiré material.

cond-mat.mes-hall

A linear-scaling algorithm for rapid computation of inelastic transitions in the presence of multiple electron scattering

Strong multiple scattering of the probe in scanning transmission electron microscopy (STEM) means image simulations are usually required for quantitative interpretation and analysis of elemental maps produced by electron energy-loss spectroscopy (EELS). These simulations require a full quantum-mechanical treatment of multiple scattering of the electron beam, both before and after a core-level inelastic transition. Current algorithms scale quadratically and can take up to a week to calculate on desktop machines even for simple crystal unit cells and do not scale well to the nano-scale heterogeneous systems that are often of interest to materials science researchers. We introduce an algorithm with linear scaling that typically results in an order of magnitude reduction in compute time for these calculations without introducing additional error and discuss approximations that further improve computational scaling for larger scale objects with modest penalties in calculation error. We demonstrate these speed-ups by calculating the atomic resolution STEM-EELS map using the L-edge transition of Fe, for of a nanoparticle 80 Å in diameter in 16 hours, a calculation that would have taken at least 80 days using a conventional multislice approach.

cond-mat.mtrl-sci

Structure retrieval at atomic resolution in the presence of multiple scattering of the electron probe

The projected electrostatic potential of a thick crystal is reconstructed at atomic-resolution from experimental scanning transmission electron microscopy data recorded using a new generation fast- readout electron camera. This practical and deterministic inversion of the equations encapsulating multiple scattering that were written down by Bethe in 1928 removes the restriction of established methods to ultrathin ($\lesssim 50$ Å) samples. Instruments already coming on-line can overcome the remaining resolution-limiting effects in this method due to finite probe-forming aperture size, spatial incoherence and residual lens aberrations.

cond-mat.mtrl-sci