SearcharxivSearch

arXiv subjects

Hans Meine

Publications and source records attributed to Hans Meine.

12 recordsLinked to original sources

Unsupervised Anomaly Detection for Image Dataset Quality Assurance in Multi-Center Breast MRI

Corrupted, inconsistent, or anomalous data silently threatens the safety and reliability of medical AI. Despite growing regulatory recognition of dataset quality assurance (QA) for high-risk medical AI, scalable automated detection remains underdeveloped. We employ unsupervised anomaly detection (AD) and out-of-distribution (OOD) detection as an automated dataset QA mechanism for multi-center dynamic contrast-enhanced breast MRI. We build a controlled AD benchmark of 17 realistic QA-relevant anomaly types from six public datasets (protocol violations, processing errors, incorrect anatomical regions) and propose a taxonomy of radiological image anomalies based on human visual perception, enabling fine-grained analysis of AD failure modes. The benchmark includes near-, medium-far-, far-OOD samples, as well as in-distribution and external normal data. Four methods are evaluated: a projection-based method extended with a domain-specific feature extractor and a novel positional encoding, a reconstruction-based approach extended to full 3D volumes with an augmented training objective, and two unmodified hybrid OOD detection methods. Medium-far- and far-OOD samples are detected reliably, whereas near-OOD samples and external normal data from unseen institutions expose method-specific differences. The 3D reconstruction-based approach best balances detection performance (AUROC: 0.936) and generalization to unseen institutions. The projection-based method with positional encoding achieves the highest overall detection performance (AUROC: 0.954). Both hybrid methods exhibit critical failure modes, confirming that methods validated for one modality or anatomy may not generalize without domain-specific adaptation. Implants and mastectomies remain an open challenge for all methods. Our results establish a foundation and practical guidance on scalable unsupervised QA in medical AI pipelines.

cs.CV

RadYOLO: Computationally Efficient 3D Object Detection and Segmentation in CT and MRI

Object detection and segmentation in three-dimensional medical images is a very active area of research. However, most proposed deep learning models carry a high computational cost, and only few aim to be broadly applicable, achieve high detection performance, and remain fast to execute on resource-constrained hardware. To address this gap, we present RadYOLO, a 3D extension of YOLO11 tailored to medical images. We compare it with nnU-Net and nnDetection on five datasets comprising CT and MRI data with varying object sizes and prevalence. RadYOLO's detection performance surpasses that of nnDetection on four of five datasets and is comparable on one. Compared to nnU-Net, RadYOLO performs better on lesion detection tasks, while nnU-Net excels at detecting large organs when precise localization is required. When rough object localization is sufficient, RadYOLO matches or outperforms nnU-Net on all five datasets. Regarding inference time, RadYOLO is 8-46x faster than nnU-Net on a GPU. Compared to nnDetection the speedup is even higher. When executed on a CPU, RadYOLO's inference runs within seconds (still faster than nnU-Net on a GPU) offering a significant advantage for clinical and edge-device deployment. RadYOLO repository: https://github.com/FraunhoferMEVIS/RadYOLO

cs.CV

On the Encapsulation of Medical Imaging AI Algorithms

In the context of collaborative AI research and development projects, it would be ideal to have self-contained encapsulated algorithms that can be easily shared between different parties, executed and validated on data at different sites, or trained in a federated manner. In practice, all of this is possible but greatly complicated, because human supervision and expert knowledge is needed to set up the execution of algorithms based on their documentation, possibly implicit assumptions, and knowledge about the execution environment and data involved. We derive and formulate a range of detailed requirements from the above goal and from specific use cases, focusing on medical imaging AI algorithms. Furthermore, we refer to a number of existing APIs and implementations and review which aspects each of them addresses, which problems are still open, and which public standards and ontologies may be relevant. Our contribution is a comprehensive collection of aspects that have not yet been addressed in their entirety by any single solution. Working towards the formulated goals should lead to more sustainable algorithm ecosystems and relates to the FAIR principles for research data, where this paper focuses on interoperability and (re)usability of medical imaging AI algorithms.

cs.SE

The Liver Tumor Segmentation Benchmark (LiTS)

In this work, we report the set-up and results of the Liver Tumor Segmentation Benchmark (LiTS), which was organized in conjunction with the IEEE International Symposium on Biomedical Imaging (ISBI) 2017 and the International Conferences on Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2017 and 2018. The image dataset is diverse and contains primary and secondary tumors with varied sizes and appearances with various lesion-to-background levels (hyper-/hypo-dense), created in collaboration with seven hospitals and research institutions. Seventy-five submitted liver and liver tumor segmentation algorithms were trained on a set of 131 computed tomography (CT) volumes and were tested on 70 unseen test images acquired from different patients. We found that not a single algorithm performed best for both liver and liver tumors in the three events. The best liver segmentation algorithm achieved a Dice score of 0.963, whereas, for tumor segmentation, the best algorithms achieved Dices scores of 0.674 (ISBI 2017), 0.702 (MICCAI 2017), and 0.739 (MICCAI 2018). Retrospectively, we performed additional analysis on liver tumor detection and revealed that not all top-performing segmentation algorithms worked well for tumor detection. The best liver tumor detection method achieved a lesion-wise recall of 0.458 (ISBI 2017), 0.515 (MICCAI 2017), and 0.554 (MICCAI 2018), indicating the need for further research. LiTS remains an active benchmark and resource for research, e.g., contributing the liver-related segmentation tasks in \url{http://medicaldecathlon.com/}. In addition, both data and online evaluation are accessible via \url{www.lits-challenge.com}.

cs.CV

Robust Segmentation Models using an Uncertainty Slice Sampling Based Annotation Workflow

Semantic segmentation neural networks require pixel-level annotations in large quantities to achieve a good performance. In the medical domain, such annotations are expensive, because they are time-consuming and require expert knowledge. Active learning optimizes the annotation effort by devising strategies to select cases for labeling that are most informative to the model. In this work, we propose an uncertainty slice sampling (USS) strategy for semantic segmentation of 3D medical volumes that selects 2D image slices for annotation and compare it with various other strategies. We demonstrate the efficiency of USS on a CT liver segmentation task using multi-site data. After five iterations, the training data resulting from USS consisted of 2410 slices (4% of all slices in the data pool) compared to 8121 (13%), 8641 (14%), and 3730 (6%) for uncertainty volume (UVS), random volume (RVS), and random slice (RSS) sampling, respectively. Despite being trained on the smallest amount of data, the model based on the USS strategy evaluated on 234 test volumes significantly outperformed models trained according to other strategies and achieved a mean Dice index of 0.964, a relative volume error of 4.2%, a mean surface distance of 1.35 mm, and a Hausdorff distance of 23.4 mm. This was only slightly inferior to 0.967, 3.8%, 1.18 mm, and 22.9 mm achieved by a model trained on all available data, but the robustness analysis using the 5th percentile of Dice and the 95th percentile of the remaining metrics demonstrated that USS resulted not only in the most robust model compared to other sampling schemes, but also outperformed the model trained on all data according to Dice (0.946 vs. 0.945) and mean surface distance (1.92 mm vs. 2.03 mm).

cs.CV

Comparative Validation of Machine Learning Algorithms for Surgical Workflow and Skill Analysis with the HeiChole Benchmark

PURPOSE: Surgical workflow and skill analysis are key technologies for the next generation of cognitive surgical assistance systems. These systems could increase the safety of the operation through context-sensitive warnings and semi-autonomous robotic assistance or improve training of surgeons via data-driven feedback. In surgical workflow analysis up to 91% average precision has been reported for phase recognition on an open data single-center dataset. In this work we investigated the generalizability of phase recognition algorithms in a multi-center setting including more difficult recognition tasks such as surgical action and surgical skill. METHODS: To achieve this goal, a dataset with 33 laparoscopic cholecystectomy videos from three surgical centers with a total operation time of 22 hours was created. Labels included annotation of seven surgical phases with 250 phase transitions, 5514 occurences of four surgical actions, 6980 occurences of 21 surgical instruments from seven instrument categories and 495 skill classifications in five skill dimensions. The dataset was used in the 2019 Endoscopic Vision challenge, sub-challenge for surgical workflow and skill analysis. Here, 12 teams submitted their machine learning algorithms for recognition of phase, action, instrument and/or skill assessment. RESULTS: F1-scores were achieved for phase recognition between 23.9% and 67.7% (n=9 teams), for instrument presence detection between 38.5% and 63.8% (n=8 teams), but for action recognition only between 21.8% and 23.3% (n=5 teams). The average absolute error for skill assessment was 0.78 (n=1 team). CONCLUSION: Surgical workflow and skill analysis are promising technologies to support the surgical team, but are not solved yet, as shown by our comparison of algorithms. This novel benchmark can be used for comparable evaluation and validation of future work.

eess.IV

Anisotropic 3D Multi-Stream CNN for Accurate Prostate Segmentation from Multi-Planar MRI

Background and Objective: Accurate and reliable segmentation of the prostate gland in MR images can support the clinical assessment of prostate cancer, as well as the planning and monitoring of focal and loco-regional therapeutic interventions. Despite the availability of multi-planar MR scans due to standardized protocols, the majority of segmentation approaches presented in the literature consider the axial scans only. Methods: We propose an anisotropic 3D multi-stream CNN architecture, which processes additional scan directions to produce a higher-resolution isotropic prostate segmentation. We investigate two variants of our architecture, which work on two (dual-plane) and three (triple-plane) image orientations, respectively. We compare them with the standard baseline (single-plane) used in literature, i.e., plain axial segmentation. To realize a fair comparison, we employ a hyperparameter optimization strategy to select optimal configurations for the individual approaches. Results: Training and evaluation on two datasets spanning multiple sites obtain statistical significant improvement over the plain axial segmentation ($p<0.05$ on the Dice similarity coefficient). The improvement can be observed especially at the base ($0.898$ single-plane vs. $0.906$ triple-plane) and apex ($0.888$ single-plane vs. $0.901$ dual-plane). Conclusion: This study indicates that models employing two or three scan directions are superior to plain axial segmentation. The knowledge of precise boundaries of the prostate is crucial for the conservation of risk structures. Thus, the proposed models have the potential to improve the outcome of prostate cancer diagnosis and therapies.

eess.IV

Automatic segmentation of the pulmonary lobes with a 3D u-net and optimized loss function

Fully-automatic lung lobe segmentation is challenging due to anatomical variations, pathologies, and incomplete fissures. We trained a 3D u-net for pulmonary lobe segmentation on 49 mainly publically available datasets and introduced a weighted Dice loss function to emphasize the lobar boundaries. To validate the performance of the proposed method we compared the results to two other methods. The new loss function improved the mean distance to 1.46 mm (compared to 2.08 mm for simple loss function without weighting).

eess.IV

Efficient Prealignment of CT Scans for Registration through a Bodypart Regressor

Convolutional neural networks have not only been applied for classification of voxels, objects, or images, for instance, but have also been proposed as a bodypart regressor. We pick up this underexplored idea and evaluate its value for registration: A CNN is trained to output the relative height within the human body in axial CT scans, and the resulting scores are used for quick alignment between different timepoints. Preliminary results confirm that this allows both fast and robust prealignment compared with iterative approaches.

eess.IV

Relevance analysis of MRI sequences for automatic liver tumor segmentation

Explainability of decisions made by deep neural networks is of high value as it allows for validation and improvement of models. This work proposes an approach to explain semantic segmentation networks by means of layer-wise relevance propagation. As an exemplary application, we investigate which MRI sequences are most relevant for liver tumor segmentation.

eess.IV

Comparison of U-net-based Convolutional Neural Networks for Liver Segmentation in CT

Various approaches for liver segmentation in CT have been proposed: Besides statistical shape models, which played a major role in this research area, novel approaches on the basis of convolutional neural networks have been introduced recently. Using a set of 219 liver CT datasets with reference segmentations from liver surgery planning, we evaluate the performance of several neural network classifiers based on 2D and 3D U-net architectures. An interesting observation is that slice-wise approaches perform surprisingly well, with mean and median Dice coefficients above 0.97, and may be preferable over 3D approaches given current hardware and software limitations.

cs.CV

Neural Network-Based Automatic Liver Tumor Segmentation With Random Forest-Based Candidate Filtering

We present a fully automatic method employing convolutional neural networks based on the 2D U-net architecture and random forest classifier to solve the automatic liver lesion segmentation problem of the ISBI 2017 Liver Tumor Segmentation Challenge (LiTS). In order to constrain the ROI in which the tumors could be located, a liver segmentation is performed first. For the organ segmentation, an ensemble of convolutional networks is trained to segment a liver using a set of 179 liver CT datasets from liver surgery planning. Inside of the liver ROI a neural network, trained using 127 challenge training datasets, identifies tumor candidates, which are subsequently filtered with a random forest classifier yielding the final tumor segmentation. The evaluation on the 70 challenge test cases resulted in a mean Dice coefficient of 0.65, ranking our method in the second place.

cs.CV