Searcharxiv⌕ Search

arXiv subjects

Hao Gao

Publications and source records attributed to Hao Gao.

At least 37 records · Page 2Linked to original sources

RAD: Training an End-to-End Driving Policy via Large-Scale 3DGS-based Reinforcement Learning

Existing end-to-end autonomous driving (AD) algorithms typically follow the Imitation Learning (IL) paradigm, which faces challenges such as causal confusion and an open-loop gap. In this work, we propose RAD, a 3DGS-based closed-loop Reinforcement Learning (RL) framework for end-to-end Autonomous Driving. By leveraging 3DGS techniques, we construct a photorealistic digital replica of the real physical world, enabling the AD policy to extensively explore the state space and learn to handle out-of-distribution scenarios through large-scale trial and error. To enhance safety, we design specialized rewards to guide the policy in effectively responding to safety-critical events and understanding real-world causal relationships. To better align with human driving behavior, we incorporate IL into RL training as a regularization term. We introduce a closed-loop evaluation benchmark consisting of diverse, previously unseen 3DGS environments. Compared to IL-based methods, RAD achieves stronger performance in most closed-loop metrics, particularly exhibiting a 3x lower collision rate. Abundant closed-loop results are presented in the supplementary material. Code is available at https://github.com/hustvl/RAD for facilitating future research.

cs.CV↗

Minibeam-pLATTICE: A novel proton LATTICE modality using minibeams

Purpose: LATTICE, a form of spatially fractionated radiation therapy that delivers high-dose peaks and low-dose valleys within the target, has been clinically utilized for treating bulky tumors. However, its application to small-to-medium-sized target remains challenging due to beam size limitations. To address this challenge, this work proposes a novel proton LATTICE (pLATTICE) modality using minibeams, namely minibeam-pLATTICE, that extends LATTICE approach for small-to-medium targets. Methods: Three minibeam-pLATTICE methods are introduced. (1) M0: a fixed minibeam orientation for all beam angles; (2) M1: alternated minibeam orientations, for consecutive beam angles; (3) M2: multiple minibeam orientations for each beam angle. For each minibeam-pLATTICE method, an optimization problem is formulated to optimize dose uniformity in target peaks and valleys, as well as dose-volume-histogram-based objectives. This problem is solved using iterative convex relaxation and alternating direction method of multipliers. Results: Three minibeam-pLATTICE methods are validated to demonstrate the feasibility of minibeam-pLATTICE for head-and-neck cases. The advantages of this modality over conventional beam (CONV) pLATTICE are evaluated by comparing peak-to-valley dose ratio (PVDR) and dose delivered to organs at risk (OAR). All three minibeam-pLATTICE modalities achieved improved plan quality compared to CONV, with M2 yielding the best results. For example, in terms of PVDR, M2=5.89, compared to CONV=4.13, M0=4.87 and M1=4.7. Conclusion: A novel minibeam-pLATTICE modality is proposed that generates lattice dose patterns for small-to-medium targets, which are not achievable with conventional pLATTICE due to beam size limitations.

physics.med-ph↗

Optimizing normal tissue sparing via spatiotemporal optimization under equivalent tumor-radical efficacy

Objective: Spatiotemporal optimization in radiation therapy involves determining the optimal number of dose delivery fractions (temporal) and the optimal dose per fraction (spatial). Traditional approaches focus on maximizing the biologically effective dose (BED) to the target while constraining BED to organs-at-risk (OAR), which may lead to insufficient BED for complete tumor cell kill. This work proposes a formulation that ensures adequate BED delivery to the target while minimizing BED to the OAR. Approach: A spatiotemporal optimization model is developed that incorporates an inequality constraint to guarantee sufficient BED for tumor cell kill while minimizing BED to the OAR. The model accounts for tumor proliferation dynamics, including lag time (delay before proliferation begins) and doubling time (time for tumor volume to double), to optimize dose fractionation. Results: The performance of our formulation is evaluated for varying lag and doubling times. The results show that mean BED to the target consistently meets the minimum requirement for tumor cell kill. Additionally, the mean BED to OAR varies based on tumor proliferation dynamics. In the prostate case with lag time of 7 days and doubling time of 2 days, it is observed that mean BED delivered to femoral head is lowest at around 20 fractions, making this an optimal choice. While in the head-and-neck case, mean BED to OAR decreases as the number of fractions increases, suggesting that a higher number of fractions is optimal. Significance: A spatiotemporal optimization model is presented that minimizes BED to the OAR while ensuring sufficient BED for tumor cell kill. By incorporating tumor lag and doubling time, the approach identifies optimal number of fractions. This model can be extended to support hyperfractionation or accelerated fractionation strategies, offering a versatile tool for clinical treatment planning.

physics.med-ph↗

A quantum computing approach to beam angle optimization

Background: Beam angle optimization (BAO) is a critical component of radiation therapy (RT) treatment planning, where small changes in beam configuration can significantly impact treatment quality, especially for proton RT. Mathematically, BAO is a mixed integer programming (MIP) problem, which is NP-hard due to its exponential growing search space. Traditional optimization techniques often struggle with computational efficiency, necessitating the development of novel approaches. Purpose: This study introduces QC-BAO, a hybrid quantum-classical approach that leverages quantum computing to solve the MIP formulation of BAO. Methods: The proposed approach, QC-BAO, models BAO as an MIP problem, incorporating binary variables for beam angle selection and continuous variables for optimizing spot intensities for proton therapy. The proposed approach employs a hybrid quantum-classical framework, utilizing quantum computing to solve the binary decision component while integrating classical optimization techniques, including iterative convex relaxation and alternating direction method of multipliers. Results: Computational experiments were conducted on clinical test cases to evaluate QC-BAO's performance against clinically verified angles and a heuristic approach, GS-BAO. QC-BAO demonstrated improved treatment plan quality over both clinical and GS-BAO. The method consistently increased the conformity index (CI) for target coverage while reducing mean and maximum doses to organs-at-risk (OAR). Additionally, QC-BAO produced the lowest objective function value, confirming its superior optimization capability. Conclusions: The findings highlight the potential of quantum computing to enhance the solution to BAO problem by demonstrated improvement in plan quality using the proposed method, QC-BAO. This study paves the way for future clinical implementation of quantum-accelerated optimization in RT.

physics.med-ph↗

AFSI: Automated Fluid-Structure Interaction Solver Development for Nonlinear Solid Mechanics

AFSI is a novel, open-source fluid-structure interaction (FSI) solver that extends the capabilities of the FEniCS finite element library through an immersed boundary (IB) framework. Designed to simulate large deformations in hyperelastic materials (such as cardiac tissue), AFSI avoids the need for expensive remeshing by coupling a Lagrangian representation of the solid with an Eulerian description of the surrounding fluid. This approach retains the full expressiveness of FEniCS's variational formulations, function spaces, and time integration schemes. Implemented in a hybrid Python/C++ architecture, AFSI allows users to define geometries, constitutive models (e.g., the Holzapfel-Ogden law for myocardium), and strain energy functions directly in Python, while delegating performance-critical tasks such as assembly and linear solvers to optimized C++ backends. Its concise and modular Python API facilitates the setup of FSI simulations, enabling users to easily modify discretization strategies or analyze results using standard FEniCS post-processing tools. By combining the flexibility of FEniCS with a robust immersed boundary formulation, AFSI empowers rapid prototyping of complex nonlinear solid-fluid interaction problems, making it a powerful tool for simulating biomechanical systems and other applications involving highly deformable structures in flow.

physics.comp-ph↗

Dominant ionic currents in rabbit ventricular action potential dynamics

Mathematical models of cardiac cell electrical activity include numerous parameters, making calibration to experimental data and individual-specific modeling challenging. This study applies Sobol sensitivity analysis, a global variance-decomposition method, to identify the most influential parameters in the Shannon model of rabbit ventricular myocyte action potential (AP). The analysis highlights the background chloride current (IClb) as the dominant determinant of AP variability. Additionally, the inward rectifier potassium current (IK1), fast/slow delayed rectifier potassium currents (IKr, IKs), sodium-calcium exchanger current (INaCa), the slow component of the transient outward potassium current (Itos), and L-type calcium current (ICaL) significantly affect AP biomarkers, including duration, plateau potential, and resting potential. Exploiting these results, a hierarchical reduction of the model is performed and demonstrates that retaining only six key parameters can capture sufficiently well individual biomarkers, with a coefficient of determination exceeding 0.9 for selected cases. These findings improve the utility of the Shannon model for personalized simulations, aiding applications like digital twins and drug response predictions in biomedical research.

q-bio.OT↗

Eccentric von Zeipel-Lidov-Kozai effects under mildly hierarchical triple systems: Influence of Brown corrections upon orbit flipping

Mildly hierarchical three-body systems are widespread in the Universe, exemplified by planets in stellar binaries and stars in black-hole binaries. In such systems, Brown Hamiltonian corrections play a crucial role in governing the long-term dynamical evolution. In this work, we extend Brown corrections to include octupole-order coupling terms, thereby formulating a more accurate dynamical model for predicting long-term dynamical behaviors. The utilization of the gauge freedom in canonical transformation shows that the quadrupole-octupole coupling term vanishes and the octupole-octupole coupling term is axisymmetric. Under triple systems with different levels of hierarchies, we systematically investigate the impact of Brown corrections on orbital flipping induced by the eccentric von Zeipel-Lidov-Kozai (ZLK) mechanism. Our analysis reveals that, as the hierarchy of triple systems becomes lower, the asymmetry in the flipping regions becomes more significant. The asymmetric structures are examined in detail using Poincare sections and perturbative techniques, showing that Brown corrections are the key factor responsible for breaking the symmetry of flipping regions. Finally, we extend the classical pendulum approximation to our refined model and demonstrate that its analytical predictions agree remarkably well with those derived from perturbative methods, particularly in the high-eccentricity regime.

astro-ph.EP↗

A fully flexible joint lattice position and dose optimization method for LATTICE therapy

Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high doses to tumor regions while sparing surrounding tissues. Traditional LATTICE uses rigid vertex patterns, limiting adaptability for irregular tumors or those near critical organs. This study introduces a novel planning method with flexible vertex placement and joint optimization of vertex positions and dose distribution, enhancing treatment precision. The method integrates vertex positioning with other treatment variables within a constrained optimization framework, allowing dynamic adjustments. Results showed that plans generated with the new method (NEW) demonstrated superior or comparable quality to conventional LATTICE plans, with improvements in the optimization objective and peak-to-valley dose ratio (PVDR). This approach offers significant improvements in target dose conformity and OAR sparing, providing an enhanced LATTICE technique.

physics.med-ph↗

A Proton Treatment Planning Method for Combining FLASH and Spatially Fractionated Radiation Therapy to Enhance Normal Tissue Protection

Background: FLASH radiation therapy (FLASH-RT) uses ultra-high dose rates to induce the FLASH effect, enhancing normal tissue sparing. In proton Bragg peak FLASH-RT, this effect is confined to high-dose regions near the target at deep tissue levels. In contrast, Spatially Fractionated Radiation Therapy (SFRT) creates alternating high- and low-dose regions with high peak-to-valley dose ratios (PVDR), sparing tissues at shallow-to-intermediate depths. Purpose: This study investigates a novel proton modality (SFRT-FLASH) that synergizes FLASH-RT and SFRT to enhance normal tissue protection across all depths. Methods: Two SFRT techniques are integrated with FLASH-RT: proton GRID therapy (pGRID) with conventional beam sizes and proton minibeam radiation therapy (pMBRT) with submillimeter beams. These are implemented as pGRID-FLASH (SB-FLASH) and minibeam-FLASH (MB-FLASH), respectively. The pGRID technique uses a scissor-beam (SB) method to achieve uniform target coverage. To meet FLASH dose (5 Gy) and dose-rate (40 Gy/s) thresholds, a single-field uniform-dose-per-fraction strategy is used. Dose and dose-rate constraints are jointly optimized, including a CTV1cm structure (a 1 cm ring around the CTV) for each field. Results: Across four clinical cases, MB-FLASH and SB-FLASH plans were benchmarked against conventional (CONV), FLASH-RT (FLASH), pMBRT (MB), and pGRID (SB) plans. SFRT-FLASH achieved high FLASH effect coverage (~60-80% in CTV1cm) while preserving PVDR (~2.5-7) at shallow-to-intermediate depths. Conclusions: We present a proton treatment planning approach that combines the FLASH effect at depth with high PVDR near the surface, enhancing normal tissue protection and advancing proton therapy.

physics.med-ph↗

Fully GPU-Accelerated, Matrix-Free Immersed Boundary Method for Complex Fiber-reinforced Hyperelastic Cardiac Models

The immersed boundary (IB) method has become a leading approach in cardiac fluid-structure interaction (FSI) modeling due to its ability to handle large deformations and complex geometries without requiring mesh regeneration. However, the use of nonlinear, fiber-reinforced hyperelastic materials for modeling soft cardiac tissues introduces challenges in computational efficiency, particularly due to the additional projection steps required for stability in the IB framework. These steps often involve sparse matrix storage and computation, which can degrade GPU performance. In this work, we present a novel, fully GPU-accelerated, matrix-free IB method for FSI in anatomically realistic cardiac models. By employing nodal coupling, our method eliminates the need for projection operations in the finite element space. Additionally, we solve the Navier-Stokes equations using Chorin's projection method combined with a matrix-free geometric multigrid solver, ensuring the entire FSI algorithm remains matrix-free and highly compatible with GPU acceleration. Our implementation features several GPU-specific optimizations, including the use of constant memory to store values of nodal basis functions and their derivatives at quadrature points, and texture memory to efficiently implement the semi-Lagrangian discretization of convection terms. These innovations maximize GPU utilization while preserving the complex mechanical behavior of soft cardiac tissue. Benchmark tests demonstrate that our GPU-accelerated solver achieves a $50\times$-$100\times$ speedup compared to a 20-core CPU implementation, with comparable accuracy.

physics.comp-ph↗

Joint Range-modulator and Spot Optimization for Bragg-peak Proton FLASH Radiotherapy

Background: Ultra-high-dose-rate (UHDR) radiation therapy has demonstrated promising potential in reducing toxicity to organs-at-risk (OARs). Proton therapy is uniquely positioned to deliver UHDR by leveraging the Bragg peak in conjunction with patient-specific range modulators (PSRMs) to generate a spread-out Bragg peak (SOBP). Existing proton FLASH (pFLASH) planning typically involves (1) generating a multi-energy IMPT plan for spot weights and (2) converting it to single-energy delivery via PSRM optimization. However, the intrinsic coupling between spot weight distribution and PSRM design has not been fully investigated. Purpose: This work proposes Joint Range-Modulator and Spot Optimization (JRSO) that simultaneously optimizes the PSRM and spot weights to improve the plan quality of conformal pFLASH therapy. Methods: Unlike the conventional method, JRSO does not require a one-to-one correspondence between beam spots and PSRM pins. To achieve better plan quality, starting from an initial solution derived from a conventional IMPT plan, JRSO alternatively updates the PSRM design and spot weights. This process progressively refines both parameters while ensuring compliance with practical delivery constraints, such as the minimum monitor-unit (MMU) requirement. Results: JRSO obtained improved plan quality compared to the conventional method. For example, in a head-and-neck (HN) case, JRSO lowered the maximum target dose from 117.6% to 107.1%, improved the conformity index from 0.74 to 0.87, and decreased the region-of-interest (ROI) effective dose from 6.50 Gy to 6.10 Gy. Conclusion: A new optimization method JRSO is proposed for conformal pFLASH radiotherapy. It outperforms the conventional approach and may extend the applicability of PSRM to more complex clinical scenarios, particularly those involving misalignments between beam spots and pins.

physics.med-ph↗

GaussianHead: High-fidelity Head Avatars with Learnable Gaussian Derivation

Constructing vivid 3D head avatars for given subjects and realizing a series of animations on them is valuable yet challenging. This paper presents GaussianHead, which models the actional human head with anisotropic 3D Gaussians. In our framework, a motion deformation field and multi-resolution tri-plane are constructed respectively to deal with the head's dynamic geometry and complex texture. Notably, we impose an exclusive derivation scheme on each Gaussian, which generates its multiple doppelgangers through a set of learnable parameters for position transformation. With this design, we can compactly and accurately encode the appearance information of Gaussians, even those fitting the head's particular components with sophisticated structures. In addition, an inherited derivation strategy for newly added Gaussians is adopted to facilitate training acceleration. Extensive experiments show that our method can produce high-fidelity renderings, outperforming state-of-the-art approaches in reconstruction, cross-identity reenactment, and novel view synthesis tasks. Our code is available at: https://github.com/chiehwangs/gaussian-head.

cs.CV↗

An energy optimization method based on mixed-integer model and variational quantum computing algorithm for faster IMPT

Intensity-modulated proton therapy (IMPT) offers superior dose conformity with reduced exposure to surrounding healthy tissues compared to conventional photon therapy. Improving IMPT delivery efficiency reduces motion-related uncertainties, enhances plan robustness, and benefits breath-hold techniques by shortening treatment time. Among various factors, energy switching time plays a critical role, making energy layer optimization (ELO) essential. This work develops an energy layer optimization method based on mixed integer model and variational quantum computing algorithm to enhance the efficiency of IMPT. The energy layer optimization problem is modeled as a mixed-integer program, where continuous variables optimize the dose distribution and binary variables indicate energy layer selection. To solve it, iterative convex relaxation decouples the dose-volume constraints, followed by the alternating direction method of multipliers (ADMM) to separate mixed-variable optimization and the minimum monitor unit (MMU) constraint. The resulting beam intensity subproblem, subject to MMU, either admits a closed-form solution or is efficiently solvable via conjugate gradient. The binary subproblem is cast as a quadratic unconstrained binary optimization (QUBO) problem, solvable using variational quantum computing algorithms. With nearly the same plan quality, the proposed method noticeable reduces the number of the used energies. For example, compared to conventional IMPT, QC can reduce the number of energy layers from 61 to 35 in HN case, from 56 to 35 in lung case, and from 59 to 32 to abdomen case. The reduced number of energies also results in fewer delivery time, e.g., the delivery time is reduced from 100.6, 232.0, 185.3 seconds to 90.7, 215.4, 154.0 seconds, respectively.

physics.med-ph↗

A mixed integer programming approach to minibeam aperture optimization for multi-collimator proton minibeam radiotherapy

Background: Multi-collimator proton minibeam radiation therapy (MC-pMBRT) has recently emerged as a versatile technique for dose shaping, enabling peak-valley dose patterns in organs-at-risk (OAR) while maintaining a uniform dose distribution in tumor. MC-pMBRT leverages a set of generic multi-slit collimators (MSC) with varying center-to-center distances. However, the current method for minibeam aperture optimization (MAO), i.e., the selection of MSC per beam angle, is manual and heuristic, resulting in computational inefficiencies and no guarantee of optimality. This work introduces a novel mixed integer programming (MIP) approach to MAO for optimizing MC-pMBRT plan quality. Methods: The proposed MIP approach jointly optimizes dose distributions, peak-to-valley dose ratio (PVDR), and selects the optimal set of MSC per beam angle. The optimization problem includes decision variables for MSC selection per beam angle and spot weights. The proposed MIP approach is a two-step process: Step1: the binary variables are optimally determined to select MSC for each beam angle; Step 2: the continuous variables are solved to determine the spot weights. Both steps utilize iterative convex relaxation and the alternating direction method of multipliers to solve the problems. Results: The proposed MIP method for MAO (MIP-MAO) was validated against the conventional heuristic method (CONV) for MC-pMBRT treatment planning. Results indicate that MIP-MAO enhances the conformity index (CI) for the target and improves PVDR for OAR. For instance, in a head-and-neck case, CI improved from 0.61 (CONV) to 0.70 (MIP-MAO); in an abdomen case, CI improved from 0.78 (CONV) to 0.83 (MIP-MAO). Additionally, MIP-MAO reduced mean doses in the body and OAR. Conclusions: A novel MIP approach for MAO in MC-pMBRT is presented, showing demonstrated improvements in plan quality and PVDR compared to the heuristic method.

physics.med-ph↗

Development and experimental validation of an in-house treatment planning system with greedy energy layer optimization for fast IMPT

Background: Intensity-modulated proton therapy (IMPT) using pencil beam technique scans tumor in a layer by layer, then spot by spot manner. It can provide highly conformal dose to tumor targets and spare nearby organs-at-risk (OAR). Fast delivery of IMPT can improve patient comfort and reduce motion-induced uncertainties. Since energy layer switching time dominants the plan delivery time, reducing the number of energy layers is important for improving delivery efficiency. Although various energy layer optimization (ELO) methods exist, they are rarely experimentally validated or clinically implemented, since it is technically challenging to integrate these methods into commercially available treatment planning system (TPS) that is not open-source. Methods: The dose calculation accuracy of IH-TPS is verified against the measured beam data and the RayStation TPS. For treatment planning, a novel ELO method via greed selection algorithm is proposed to reduce energy layer switching time and total plan delivery time. To validate the planning accuracy of IH-TPS, the 3D gamma index is calculated between IH-TPS plans and RayStation plans for various scenarios. Patient-specific quality-assurance (QA) verifications are conducted to experimentally verify the delivered dose from the IH-TPS plans for several clinical cases. Results: Dose distributions in IH-TPS matched with those from RayStation TPS, with 3D gamma index results exceeding 95% (2mm, 2%). The ELO method significantly reduced the delivery time while maintaining plan quality. For instance, in a brain case, the number of energy layers was reduced from 78 to 40, leading to a 62% reduction in total delivery time. Patient-specific QA validation with the IBA Proteus ONE proton machine confirmed a >95% pass rate for all cases.

physics.med-ph↗

Multi-IMPT: a biologically equivalent approach to proton ARC therapy

Objective: Proton spot-scanning arc therapy (ARC) is an emerging modality that can improve the high-dose conformity to targets compared with standard intensity-modulated proton therapy (IMPT). However, the efficient treatment delivery of ARC is challenging due to the required frequent energy changes during the continuous gantry rotation. This work proposes a novel method that delivers a multiple IMPT (multi-IMPT) plan that is equivalent to ARC in terms of biologically effective dose (BED). Approach: The proposed multi-IMPT method utilizes a different subset of limited number of beam angles in each fraction for dose delivery. Due to the different dose delivered to organs at risk (OAR) in each fraction, we optimize biologically effective dose (BED) for OAR and the physical dose delivered for target in each fraction. The BED-based multi-IMPT inverse optimization problem is solved via the iterative convex relaxation method and the alternating direction method of multipliers. The effectiveness of the proposed multi-IMPT method is evaluated in terms of dose objectives in comparison with ARC. Main results: Multi-IMPT provided similar plan quality with ARC. For example, multi-IMPT provided better OAR sparing and slightly better target dose coverage for the prostate case; similar dose distribution for the lung case; slightly worse dose coverage for the brain case; better dose coverage but slightly higher BED in OAR for the head-and-neck case. Significance: We have proposed a multi-IMPT approach to deliver ARC-equivalent plan quality. Keywords: biologically effective dose (BED), proton arc therapy

physics.med-ph↗

An Oversampling-enhanced Multi-class Imbalanced Classification Framework for Patient Health Status Prediction Using Patient-reported Outcomes

Patient-reported outcomes (PROs) directly collected from cancer patients being treated with radiation therapy play a vital role in assisting clinicians in counseling patients regarding likely toxicities. Precise prediction and evaluation of symptoms or health status associated with PROs are fundamental to enhancing decision-making and planning for the required services and support as patients transition into survivorship. However, the raw PRO data collected from hospitals exhibits some intrinsic challenges such as incomplete item reports and imbalance patient toxicities. To the end, in this study, we explore various machine learning techniques to predict patient outcomes related to health status such as pain levels and sleep discomfort using PRO datasets from a cancer photon/proton therapy center. Specifically, we deploy six advanced machine learning classifiers -- Random Forest (RF), XGBoost, Gradient Boosting (GB), Support Vector Machine (SVM), Multi-Layer Perceptron with Bagging (MLP-Bagging), and Logistic Regression (LR) -- to tackle a multi-class imbalance classification problem across three prevalent cancer types: head and neck, prostate, and breast cancers. To address the class imbalance issue, we employ an oversampling strategy, adjusting the training set sample sizes through interpolations of in-class neighboring samples, thereby augmenting minority classes without deviating from the original skewed class distribution. Our experimental findings across multiple PRO datasets indicate that the RF and XGB methods achieve robust generalization performance, evidenced by weighted AUC and detailed confusion matrices, in categorizing outcomes as mild, intermediate, and severe post-radiation therapy. These results underscore the models' effectiveness and potential utility in clinical settings.

cs.LG↗

LASER: Script Execution by Autonomous Agents for On-demand Traffic Simulation

Autonomous Driving Systems (ADS) require diverse and safety-critical traffic scenarios for effective training and testing, but the existing data generation methods struggle to provide flexibility and scalability. We propose LASER, a novel frame-work that leverage large language models (LLMs) to conduct traffic simulations based on natural language inputs. The framework operates in two stages: it first generates scripts from user-provided descriptions and then executes them using autonomous agents in real time. Validated in the CARLA simulator, LASER successfully generates complex, on-demand driving scenarios, significantly improving ADS training and testing data generation.

cs.RO↗