Searcharxiv⌕ Search

arXiv subjects

Hao Ma

Publications and source records attributed to Hao Ma.

At least 145 records · Page 8Linked to original sources

Gross beta determination using a scintillating fiber array detector for drinking water

A scintillating fiber array measurement system for gross beta is developed to achieve real-time monitoring of radioactivity in drinking water. The detector consists of 1,096 scintillating fibers, both sides of the fibers connect to a photomultiplier tube, and they are placed in a stainless steel tank. The detector parameters of working voltage, background counting rate and stability of the detector were tested, and the detection efficiency was calibrated using a standard solution of potassium chloride. Through experiment, the background counting rate of the detector is 38.31 cps and the detection efficiency for $β$ particles is 0.37 cps per Bq per liter; the detector can reach its detection limit of 1.0 Bq per liter for $β$ particles within 100 minutes without pre-concentration.

physics.ins-det↗

single-electron events and 0νββ events in CdZnTe: A Monte Carlo simulation study

In neutrinoless double beta (0νββ) decay experiments, the diversity of topological signatures of different particles provides an important tool to distinguish double beta events from background events and reduce background rates. Aiming at suppressing the single-electron backgrounds which are most challenging, several groups have established Monte Carlo simulation packages to study the topological characteristics of single-electron events and 0νββ events and develop methods to differentiate them. In this paper, applying the knowledge of graph theory, a new topological signature called REF track (Refined Energy-Filtered track) is proposed and proven to be an accurate approximation of the real particle trajectory. Based on the analysis of the energy depositions along the REF track of single-electron events and 0νββ events, the REF energy deposition models for both events are proposed to indicate the significant differences between them. With these differences, this paper presents a new discrimination method, which, in the Monte Carlo simulation, achieved a single-electron rejection factor of 93.8+-0.3 (stat.)% as well as a 0νββ efficiency of 85.6+-0.4 (stat.)% with optimized parameters in CdZnTe.

physics.ins-det↗

Electron Track Reconstruction and Improved Modulation for Photoelectric X-ray Polarimetry

The key to photoelectric X-ray polarimetry is the determination of the emission direction of photoelectrons. Because of the low mass of an electron, the ionisation trajectory is not straight and the useful information needed for polarimetry is stored mostly in the initial part of the track where less energy is deposited. We present a new algorithm, based on the shortest path problem in graph theory, to reconstruct the 2D electron track from the measured image that is blurred due to transversal diffusion along drift and multiplication in the gas chamber. Compared with previous methods based on moment analysis, this algorithm allows us to identify the photoelectric interaction point more accurately and precisely for complicated tracks resulting from high energy photons or low pressure chambers. This leads to a better position resolution and a higher degree of modulation toward high energy X-rays. The new algorithm is justified using simulations and measurements with the gas pixel detector (GPD), and it should also work for other polarimetric techniques such as a time projection chamber (TPC). As the improvement is restricted in the high energy band, this new algorithm shows limited improvement for the sensitivity of GPD polarimeters, but it may have a larger potential for low-pressure TPC polarimeters.

physics.ins-det↗

The first result on 76Ge neutrinoless double beta decay from CDEX-1 experiment

We report the first result on Ge-76 neutrinoless double beta decay from CDEX-1 experiment at China Jinping Underground Laboratory. A mass of 994 g p-type point-contact high purity germanium detector has been installed to search the neutrinoless double beta decay events, as well as to directly detect dark matter particles. An exposure of 304 kg*day has been analyzed. The wideband spectrum from 500 keV to 3 MeV was obtained and the average event rate at the 2.039 MeV energy range is about 0.012 count per keV per kg per day. The half-life of Ge-76 neutrinoless double beta decay has been derived based on this result as: T 1/2 > 6.4*10^22 yr (90% C.L.). An upper limit on the effective Majorana-neutrino mass of 5.0 eV has been achieved. The possible methods to further decrease the background level have been discussed and will be pursued in the next stage of CDEX experiment.

hep-ex↗

Compton suppression in BEGe detectors by digital pulse shape analysis

A new method of pulse shape discrimination (PSD) for BEGe detectors is developed to suppress Compton-continuum by digital pulse shape analysis (PSA), which helps reduce the Compton background level in gamma ray spectrometry. A decision parameter related to the rise time of a pulse shape was presented. The method was verified by experiments using 60Co and 137Cs sources. The result indicated that the 60Co Peak to Compton ratio and the Cs-Peak to Co-Compton ratio could be improved by more than two and three times, respectively.

physics.ins-det↗

Neutron background measurements at China Jinping underground laboratory with a Bonner Multi-sphere Spectrometer

The neutron background spectrum from thermal neutron to 20 MeV fast neutron was measured at the first experimental hall of China Jinping underground laboratory with a Bonner multi-sphere spectrometer. The measurement system was validated by a Cf252 source and inconformity was corrected. Due to micro charge discharge, the dataset was screened and background from the steel of the detectors was estimated by MC simulation. Based on genetic algorithm we obtained the energy distribution of the neutron and the total flux of neutron was (2.69 +/-1.02) *10^-5 cm^-2s^-1

physics.ins-det↗

Optimization of an underwater in-situ LaBr3:Ce spectrometer with energy self-calibration and efficiency calibration

An underwater in situ gamma ray spectrometer based on LaBr3 was developed and optimized to monitor marine radioactivity. The intrinsic background mainly from La138 and Ac227 of LaBr3 was well determined by low background measurement and pulse shape discrimination method. A method of self-calibration using three internal contaminant peaks was proposed to eliminate the peak shift during long term monitoring. With experiments under different temperatures, the method was proved to be helpful for maintaining long term stability. To monitor the marine radioactivity, the spectrometer efficiency was calculated via water tank experiment as well as Monte Carlo simulation.

physics.ins-det↗

Characterization study of a broad-energy germanium detector at CJPL

The ability of background discrimination using pulse shape discrimination (PSD) in broad-energy germanium (BEGe) detectors makes them as competitive candidates for neutrinoless double beta decay (0ν\b{eta}\b{eta}) experiments. The measurements of key parameters for detector modeling in a commercial p-type BEGe detector are presented in this paper. Point-like sources were used to investigate the energy resolution and linearity of the detector. A cylindrical volume source was used for the efficiency calibration. With an assembled device for source positioning, a collimated 133Ba point-like source was used to scan the detector and investigate the active volume. A point-like source of 241Am was used to measure the dead layer thicknesses, which are approximately 0.17 mm on the front and 1.18 mm on the side. The described characterization method will play an important role in the 0ν\b{eta}\b{eta} experiments with BEGe detectors at China JinPing underground Laboratory (CJPL) in the future.

physics.ins-det↗

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

A prototype of LaBr3:Ce in situ gamma-ray spectrometer for marine environmental monitoring is developed and applied for in situ measurement. A 3-inch LaBr3:Ce scintillator is used in the detector, and a digital pulse process electronics is chosen as the pulse height analyzer. For this prototype, the energy response of the spectrometer is linear and the energy resolution of 662keV is 2.6% (much better than NaI). With the measurement of the prototype in a water tank filled with 137Cs, the detect efficiency for 137Cs is (0.288 0.01)cps/(Bq/L), which is close to the result of Monte Carlo simulation, 0.283cps/(Bq/L). With this measurement, the MDAC for 137Cs in one hour has been calculated to 0.78Bq/L, better than that of NaI(Tl) in-situ gamma spectrometer, which is ~1.0Bq/L.

physics.ins-det↗

The characteristics of a low background germanium gamma ray spectrometer at China JinPing underground Laboratory

A low background germanium gamma ray spectrometer, GeTHU, has been installed at China JinPing underground Laboratory. The integral background count rate between 40 and 2700 keV was 0.6 cpm, and the origin was studied by Monte Carlo simulation. Detection limits and efficiencies were calculated for selected gamma peaks. Boric acid and silica sand samples were measured and 137Cs contamination was found in boric acid. GeTHU will be mainly used to measure environmental samples and screen materials in dark matter experiments.

physics.ins-det↗

Characterization of large area photomultiplier ETL 9357FLB for liquid argon detector

The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium detectors. A low-background and large-area photomultiplier tube (PMT) immersed in liquid argon will be used to read out the light signal from the argon. In this paper we carry out a careful evaluation on the performance of the PMT operating at both room and cryogenic temperatures. Based on the single photoelectron response model, the absolute gain and resolution of the PMT were measured. This has laid a foundation for PMT selection, calibration and signal analysis in the forthcoming CDEX experiments.

physics.ins-det↗

A background simulation method for cosmogenic nuclides inside HPGe detectors for rare event experiments

Cosmogenic nuclides inside germanium detectors contribute background noise spectra quite different from ordinary external sources. We propose and discuss a nuclide decay and level transition model based on graph theory to understand the background contribution of the decay of cosmogenic nuclides inside a germanium crystal. In this work, not only was the level transition process, but the detector response time was also taken into consideration to decide whether or not to apply coincidence summing-up. We simulated the background spectrum of the internal cosmogenic nuclides in a germanium detector, and found some unique phenomena caused by the coincidence summing-up effect in the simulated spectrum. Thus, the background spectrum of each cosmogenic nuclide can be quantitatively obtained.

physics.ins-det↗

Coherence phenomena between initial and final state radiation in a dense QCD medium

In this work we investigate medium modifications to the interference pattern between initial and final state radiation. We compute single gluon production off a highly energetic parton that undergoes a hard scattering and subsequently crosses a dense QCD medium of finite size. We extend our previous studies obtained at first order in opacity by providing general results for multiple soft scatterings and their specific formulation within the harmonic oscillator approximation. We show that there is a gradual onset of decoherence between the initial and final state radiation due to multiple scatterings, that opens the phase space for large angle emissions. By examining the multiplicity of produced gluons, we observe a potentially large double logarithmic enhancement for dense media and small opening angles. This result points to a possible modification of the evolution equations due to a QCD medium of finite size. We briefly comment on the phenomenological consequences of this setup in high-energy nuclear collisions.

hep-ph↗

Measurement of Cosmic Ray Flux in China JinPing underground Laboratory

China JinPing underground Laboratory (CJPL) is the deepest underground laboratory presently running in the world. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the cosmic ray on the ground laboratory near CJPL. Based on the underground experimental data taken from November 2010 to December 2011 in CJPL, which has effective live time of 171 days, the cosmic ray muon flux in CJPL is measured to be (2.0+-0.4)*10^(-10)/(cm^2)/(s). The ultra-low cosmic ray background guarantees CJPL's ideal environment for dark matter experiment.

physics.ins-det↗

The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches

The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.

physics.ins-det↗

Introduction of the CDEX experiment

Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.

physics.ins-det↗

Coherence and broadening effects in medium induced gluon radiation

Interferences between different emitters in the multi-parton shower is the building block of QCD jet physics in vacuum. The presence of a hot medium made of quarks and gluons is expected to alter this interference pattern. To study such effects, we derive the gluon emission spectrum off an "asymptotic quark" traversing a hot and dense QCD medium at first order in the medium density. The resulting induced gluon distribution gets modified when the new interference terms between the initial and final quark are included. We comment on the possible phenomenological consequences of this new contribution for jet observables in heavy-ion collisions.

hep-ph↗

Interference between initial and final state radiation in a QCD medium

We investigate the color coherence pattern between initial and final state radiation in the presence of a QCD medium. We derive the medium-induced gluon spectrum of an "asymptotic" parton which suffers a hard scattering and subsequently crosses the medium. The angular distribution of the induced gluon spectrum is modified when one includes interference terms between the incoming and the outgoing parton at finite angle between them. The coherent, incoherent and soft limits of the medium-induced gluon spectrum are studied. In the soft limit, we provide a simple and intuitive probabilistic picture which could be of interest for Monte Carlo implementations. The configuration studied here may have phenomenological consequences in high energy nuclear collisions.

hep-ph↗