Instrument response generation using high-resolution 3D voxelization of GRBAlpha and VZLUSAT-2 satellites with MEGAlib

Pathfinder gamma-ray burst (GRB) detecting CubeSat missions such as GRBAlpha and VZLUSAT-2 have demonstrated the successful application of scintillator detectors with silicon photomultipliers in low Earth orbit (LEO). To produce more comprehensive scientific analysis of the data, the effective area of the detector needs to be characterised at different energies. A large part of this process requires a thorough understanding of the detectors response matrices based on the satellite mass model typically performed through Geant4 and MEGAlib simulations. We use a novel voxelization and binning methodology to turn complex 3D geometries into MEGAlib-compatible versions, and we validate these experiments by showing that the simulation results with Geant4 agree within an order of 10%. We use MEGAlib simulations from various angles around the spacecraft to generate instrumental response matrices for both simple and complex geometries, in the case of GRBAlpha and VZLUSAT-2, respectively.

astro-ph.IM

Energy calibration of GTM on ground

The Gamma-ray Transients Monitor (GTM) on board the Formosat-8B (FS-8B) satellite is designed to detect and localize Gamma-Ray Bursts (GRBs). By utilizing 2+2 CITIROC chips to manipulate 4+4 detectors, which are composed of GAGG(Ce) scintillators coupled with Silicon Photomultipliers (SiPMs) and oriented in various directions to achieve all-sky coverage, the GRB saturation fluences of GTM in the 50 keV to 1 MeV range for Short GRBs (SGRBs) and Long GRBs (LGRBs) were estimated to be about $3.1 \times 10^{-4}$ and $5.0 \times 10^{-3}\ {\rm erg/cm^2}$, respectively, based on simulations. To precisely interpret the GTM readout signal in terms of energy, several measurements for isotope and gain calibration were conducted. Despite encountering issues with crosstalk and SiPM saturation effect in the data, the energy spectrum can still be recovered by appropriately discarding channel noise and mapping with the correct ADC-to-energy relation. This paper summarizes the energy resolution of GTM and the linear variations in the relationship between photon energy and readout signal. At 662 keV, the energy resolution is about 16 %. Also, it demonstrates that greater gain is achieved by increasing voltage or decreasing temperature.

astro-ph.IM