SearcharxivSearch

arXiv subjects

Hao-Yang Xing

Publications and source records attributed to Hao-Yang Xing.

12 recordsLinked to original sources

Molecular Dynamics Simulations on Nuclear Recoils in Silicon Crystals towards Single Electron-Hole Pair Ionization Yields

We have developed a novel methodology utilizing molecular dynamics simulations to evaluate the ionization yields of nuclear recoils in crystalline silicon. This approach enables analytical exploration of atomic-scale transport within the lattice without necessitating parameterization. The quenching factors across the nuclear recoil energy range from 20 eV to 10 keV have been thoroughly investigated. A remarkable agreement with experimental data is achieved, particularly for the minimal energy regime conducted to date, reaching the level of a single electron-hole pair. This work presents evidence of a crucial and fundamental distribution of the quenching factor, which can be associated to the collisional interactions underlying the transport phenomena. The region below 4 keV of the quenching factor, where discrepancies have been observed with the Lindhard's model, is found to be significantly attributed to the lattice binding effect and the specific crystal structure. In contrast, a gradual functional relationship is identified below approximately 100 eV, indicating that the quenching factor is influenced by the crystallographic orientation of the target material. From a distributional perspective, our analysis allows for the determination of the minimum exclusion mass for the dark matter nucleon elastic scattering channel at 0.29 $\mathrm{GeV}/c^2$, thereby significantly enhancing sensitivity for the sub-$\mathrm{GeV}/c^2$ mass region.

astro-ph.IM

Germanium Atomic Compton Scattering Measurements and ${ab}$ ${initio}$ Many-Body Calculations: Implications for Electronic recoil Dark Matter Detection

Diverse searches for direct dark matter (DM) in effective electromagnetic and leptophilic interactions resulting from new physics, as well as Weakly Interacting Massive Particles (WIMPs) with unconventional electronic recoils, are intensively pursued. Low-energy backgrounds from radioactive $γ$ rays via Compton scattering and photon coherent scattering are unavoidable in terrestrial detectors. The interpretation of dark matter experimental data is dependent on a better knowledge of the background in the low-energy region. We provide a 2.3% measurement of atomic Compton scattering in the low momentum transfer range of 180 eV/c to 25 keV/c, using a 10-g germanium detector bombarded by a $^{137}\mathrm{Cs}$ source with a 7.2 m-Curie radioactivity and the scatter photon collected by a cylindrical NaI[Tl] detector. The ability to detect Compton scattering's doubly differential cross section (DDCS) gives a special test for clearly identifying the kinematic restraints in atomic many-body systems, notably the Livermore model. Additionally, a low-energy-background comparison is made between coherent photon scattering and Compton scattering replacing the scattering function of ${GEANT4}$@software, which uses a completely relativistic impulse approximation (RIA) together with Multi-Configuration Dirac-Fock (MCDF) wavefunctions. For the purpose of investigating sub-GeV mass and electronic-recoil dark matter theories, signatures including low energy backgrounds via high energy $γ$ rays in germanium targets are discussed.

astro-ph.IM

Low Radon Concentration Measurement with a Radon-Dissolved Liquid Scintillator Pilot Detector

We construct a high sensitivity radon pilot detector using liquid scintillator dissolved radon for the CDEX rare-event searches program. The CDEX-10 project employs a germanium detector array immersed in a massive liquid nitrogen tank. However, radon emanated from the surface of the tank can contribute background. As a result, radon contamination in the liquid nitrogen tank must be regulated and monitored, which necessitates the use of a low-level Rn measuring device. The radon-dissolved liquid scintillator (LS) detectors utilizes cascade decay selections, yielding a unique signature. All background events occurring in the LS, with regard to the system and co-efficiency of Rn absorption, have been studied. Background activity is measured to be 59.8$\pm$18.4 $μ$Bq per 300 mL LS. Meanwhile, it shows that radon concentration absorbed by LS will be saturated and is linearly related to radon concentration in nitrogen gas. Furthermore, the co-efficiency factor can be optimized by lowering temperature or raising pressure. Eventually the detection limit for 222^Rn in nitrogen gas is observed to be 9.6 mBq/m^3.

physics.ins-det

Recovery of Saturated $γ$ Signal Waveforms by Artificial Neural Networks

Particle may sometimes have energy outside the range of radiation detection hardware so that the signal is saturated and useful information is lost. We have therefore investigated the possibility of using an Artificial Neural Network (ANN) to restore the saturated waveforms of $γ$ signals. Several ANNs were tested, namely the Back Propagation (BP), Simple Recurrent (Elman), Radical Basis Function (RBF) and Generalized Radial Basis Function (GRBF) neural networks (NNs) and compared with the fitting method based on the Marrone model. The GBRFNN was found to perform best.

physics.data-an

Response of gadolinium doped liquid scintillator to charged particles: measurement based on intrinsic U/Th contamination

A measurement is reported for the response to charged particles of a liquid scintillator named EJ-335 doped with 0.5% gadolinium by weight. This liquid scintillator was used as the detection medium in a neutron detector. The measurement is based on the in-situ $α$-particles from the intrinsic Uranium and Thorium contamination in the scintillator. The $β$-$α$ and the $α$-$α$ cascade decays from the U/Th decay chains were used to select $α$-particles. The contamination levels of U/Th were consequently measured to be $(5.54\pm0.15)\times 10^{-11}$ g/g, $(1.45\pm0.01)\times 10^{-10}$ g/g and $(1.07\pm0.01)\times 10^{-11}$ g/g for $^{232}$Th, $^{238}$U and $^{235}$U, respectively, assuming secular equilibrium. The stopping power of $α$-particles in the liquid scintillator was simulated by the TRIM software. Then the Birks constant, $kB$, of the scintillator for $α$-particles was determined to be $(7.28\pm0.23)$ mg/(cm$^{2}\cdot$MeV) by Birks' formulation. The response for protons is also presented assuming the $kB$ constant is the same as for $α$-particles.

physics.ins-det

Measurement of the fast neutron background at the China Jinping Underground Laboratory

We report on the measurements of the fluxes and spectra of the environmental fast neutron background at the China Jinping Underground Laboratory (CJPL) with a rock overburden of about 6700 meters water equivalent, using a liquid scintillator detector doped with 0.5% gadolinium. The signature of a prompt nuclear recoil followed by a delayed high energy $γ$-ray cascade is used to identify neutron events. The large energy deposition of the delayed $γ$-rays from the $(n, γ)$ reaction on gadolinium, together with the excellent n-$γ$ discrimination capability provides a powerful background suppression which allows the measurement of a low intensity neutron flux. The neutron flux of $(1.51\pm0.03(stat.)\pm0.10(syst.))\times10^{-7}$ cm$^{-2}$s$^{-1}$ in the energy range of 1 -- 10 MeV in the Hall A of CJPL was measured based on 356 days of data. In the same energy region, measurement with the same detector placed in a one meter thick polyethylene room gives a significantly lower flux of $(4.9\pm0.9(stat.)\pm0.5(syst.))\times10^{-9}$ cm$^{-2}$s$^{-1}$ with 174 days of data. This represents a measurement of the lowest environmental fast neutron background among the underground laboratories in the world, prior to additional experiment-specific attenuation. Additionally, the fast neutron spectra both in the Hall A and the polyethylene room were reconstructed with the help of GEANT4 simulation.

physics.ins-det

Discrimination of neutrons and γ-rays in liquid scintillator based on Elman neural network

In this work, a new neutron and γ(n/γ) discrimination method based on an Elman Neural Network (ENN) is proposed to improve the discrimination performance of liquid scintillator (LS) detectors. Neutron and γ data were acquired from an EJ-335 LS detector, which was exposed in a 241Am-9Be radiation field. Neutron and γ events were discriminated using two methods of artificial neural network including the ENN and a typical Back Propagation Neural Network (BPNN) as a control. The results show that the two methods have different n/γ discrimination performances. Compared to the BPNN, the ENN provides an improved of Figure of Merit (FOM) in n/γ discrimination. The FOM increases from 0.907 {\pm} 0.034 to 0.953 {\pm} 0.037 by using the new method of the ENN. The proposed n/γ discrimination method based on ENN provides a new choice of pulse shape discrimination in neutron detection.

physics.ins-det

Measurement of photoelectron yield of the prototype for the CDEX-10 liquid argon detector

The China Dark Matter Experiment (CDEX) is a low background experiment at China Jinping Underground Laboratory (CJPL) designed to directly detect dark matter with a high-purity Germanium (HPGe) detector. In the second phase CDEX-10 with a 10 kg Germanium array detector system, the liquid argon (LAr) anti-compton active shielding and cooling system is proposed. For purpose of studying the properties of LAr detector, a prototype with an active volume of 7 liters of liquid argon was built and operated. The photoelectron yields, as a critically important parameter for the prototype detector, have been measured to be 0.051-0.079 p.e./keV for 662 keV Gamma lines at different positions. The good agreement between the experimental and simulation results has provided a quite reasonable understanding and determination of the important parameters such as the Surviving Fraction of the Ar2 excimers, the absorption length for 128 nm photons in liquid argon, the reflectivity of Teflon and so on.

physics.ins-det

Study of the material photon and electron background and the liquid argon detector veto efficiency of the CDEX-10 experiment

The China Dark Matter Experiment (CDEX) is located at the China Jinping underground laboratory (CJPL) and aims to directly detect the WIMP flux with high sensitivity in the low mass region. Here we present a study of the predicted photon and electron backgrounds including the background contribution of the structure materials of the germanium detector, the passive shielding materials, and the intrinsic radioactivity of the liquid argon that serves as an anti-Compton active shielding detector. A detailed geometry is modeled and the background contribution has been simulated based on the measured radioactivities of all possible components within the GEANT4 program. Then the photon and electron background level in the energy region of interest (<10^-2 events kg-1 day-1 keV-1 (cpkkd)) is predicted based on Monte Carlo simulations. The simulated result is consistent with the design goal of CDEX-10 experiment, 0.1 cpkkd, which shows that the active and passive shield design of CDEX-10 is effective and feasible.

physics.ins-det

Characterization of large area photomultiplier ETL 9357FLB for liquid argon detector

The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium detectors. A low-background and large-area photomultiplier tube (PMT) immersed in liquid argon will be used to read out the light signal from the argon. In this paper we carry out a careful evaluation on the performance of the PMT operating at both room and cryogenic temperatures. Based on the single photoelectron response model, the absolute gain and resolution of the PMT were measured. This has laid a foundation for PMT selection, calibration and signal analysis in the forthcoming CDEX experiments.

physics.ins-det

The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches

The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.

physics.ins-det

Introduction of the CDEX experiment

Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.

physics.ins-det