SearcharxivSearch

arXiv subjects

Harald Lück

Publications and source records attributed to Harald Lück.

14 recordsLinked to original sources

Mitigating effects of nonlinearities in homodyne quadrature interferometers

Homodyne Quadrature interferometers (HoQI) are an interferometric displacement sensing scheme proven to have excellent noise performance, making them a strong candidate for sensing and control schemes in gravitational wave detector seismic isolation. Like many interferometric schemes, HoQIs are prone to nonlinear effects when measuring displacements. These nonlinearities, if left unsuppressed, would substantially limit the use cases of HoQIs. This paper first shows a means of measuring and quantifying nonlinearities using a working HoQI and a mechanical resonator. We then demonstrate a method for real-time correction of these nonlinearities and several approaches for accurately calibrating the correction technique. By correcting in real time, we remove one of the biggest obstacles to including HoQIs in upgrades to future gravitational wave detectors. Finally, we discuss how to post correct data from HoQIs, suppressing even further the nonlinearity-induced errors, broadening the appeal of such sensors to other applications where measurement data can be reconstructed after the fact. We demonstrate all of this on a working HoQI system and show the measured suppression of nonlinear effects from each of these methods. Our work makes HoQIs a more broadly applicable tool for displacement sensing.

physics.ins-det

GEO600 beam splitter thermal compensation system: new design and commissioning

Gravitational waves have revolutionised the field of astronomy by providing scientists with a new way to observe the universe and gain a better understanding of exotic objects like black holes. Several large-scale laser interferometric gravitational wave detectors (GWDs) have been constructed worldwide, with a focus on achieving the best sensitivity possible. However, in order for a detector to operate at its intended sensitivity, its optics must be free from imperfections such as thermal lensing effects. In the GEO\,600 gravitational wave detector, the beam splitter (BS) experiences a significant thermal lensing effect due to the high power build-up in the Power Recycling Cavity (PRC) combined with a very small beam waist. This causes the fundamental mode to be converted into higher order modes (HOMs), subsequently impacting the detector's performance. To address this issue, the GEO\,600 detector is equipped with a thermal compensation system (TCS) applied to the BS. This involves projecting a spatially tunable heating pattern through an optical system onto the beam splitter. The main objective of the TCS is to counteract the thermal lens at the BS and restore the detector to its ideal operating condition. This paper presents the new beam splitter TCS in GEO\,600, its commissioning, and its effect on strain sensitivity. It also outlines the planned upgrade to further enhance the performance of the TCS.

astro-ph.IM

Characterization and evasion of backscattered light in the squeezed-light enhanced gravitational wave interferometer GEO 600

Squeezed light is injected into the dark port of gravitational wave interferometers, in order to reduce the quantum noise. A fraction of the interferometer output light can reach the OPO due to sub-optimal isolation of the squeezing injection path. This backscattered light interacts with squeezed light generation process, introducing additional measurement noise. We present a theoretical description of the noise coupling mechanism. We propose a control scheme to achieve a de-amplification of the backscattered light inside the OPO with a consequent reduction of the noise caused by it. The scheme was implemented at the GEO 600 detector and has proven to be crucial in maintaining a good level of quantum noise reduction of the interferometer for high parametric gain of the OPO. In particular, the mitigation of the backscattered light noise helped in reaching 6dB of quantum noise reduction [Phys. Rev. Lett. 126, 041102 (2021)]. The impact of backscattered-light-induced noise on the squeezing performance is phenomenologically equivalent to increased phase noise of the squeezing angle control. The results discussed in this paper provide a way for a more accurate estimation of the residual phase noise of the squeezed light field.

physics.optics

First demonstration of neural sensing and control in a kilometer-scale gravitational wave observatory

Suspended optics in gravitational wave (GW) observatories are susceptible to alignment perturbations, particularly slow drifts over time, due to variations in temperature and seismic levels. Such misalignments affect the coupling of the incident laser beam into the optical cavities, degrade both circulating power and optomechanical photon squeezing and thus decrease the astrophysical sensitivity to merging binaries. Traditional alignment techniques involve differential wavefront sensing using multiple quadrant photodiodes but are often restricted in bandwidth and are limited by the sensing noise. We present the first-ever successful implementation of neural network-based sensing and control at a gravitational wave observatory and demonstrate low-frequency control of the signal recycling mirror at the GEO 600 detector. Alignment information for three critical optics is simultaneously extracted from the interferometric dark port camera images via a CNN-LSTM network architecture and is then used for MIMO control using soft actor-critic-based deep reinforcement learning. Overall sensitivity improvement achieved using our scheme demonstrates deep learning's capabilities as a viable tool for real-time sensing and control for current and next-generation GW interferometers.

physics.ins-det

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det

Direct limits for scalar field dark matter from a gravitational-wave detector

The nature of dark matter remains unknown to date; several candidate particles are being considered in a dynamically changing research landscape. Scalar field dark matter is a prominent option that is being explored with precision instruments, such as atomic clocks and optical cavities. Here we report on the first direct search for scalar field dark matter utilising a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits for the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beamsplitter of the GEO$\,$600 interferometer. The new constraints improve upon bounds from previous direct searches by more than six orders of magnitude, and are in some cases more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be probed or constrained with direct searches using gravitational-wave detectors, and highlights the potential of quantum-enhanced interferometry for dark matter detection.

gr-qc

Bilinear noise subtraction at the GEO 600 observatory

Longitudinal control signals used to keep gravitational wave detectors at a stable operating point are often affected by modulations from test mass misalignments leading to an elevated noise floor ranging from 50 to 500 Hz. Nonstationary noise of this kind results in modulation sidebands and increases the number of glitches observed in the calibrated strain data. These artifacts ultimately affect the data quality and decrease the efficiency of the data analysis pipelines looking for astrophysical signals from continuous waves as well as the transient events. In this work, we develop a scheme to subtract one such bilinear noise from the gravitational wave strain data and demonstrate it at the GEO 600 observatory. We estimate the coupling by making use of narrow-band signal injections that are already in place for noise projection purposes and construct a coherent bilinear signal by a two-stage system identification process. We improve upon the existing filter design techniques by employing a Bayesian adaptive directed search strategy that optimizes across the several key parameters that affect the accuracy of the estimated model. The scheme takes into account the possible nonstationarities in the coupling by periodically updating the involved filter coefficients. The resulting postoffline subtraction leads to a suppression of modulation sidebands around the calibration lines along with a broadband reduction of the midfrequency noise floor. The observed increase in the astrophysical range and a reduction in the occurrence of nonastrophysical transients suggest that the above method is a viable data cleaning technique for current and future generation gravitational wave observatories.

gr-qc

First demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory

Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO\,600 observatory and demonstrate for the first time a reduction of quantum noise up to $6.03 \pm 0.02$ dB in a kilometer-scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of four. Achieving this milestone, a key goal for the upgrades of the advanced detectors, required a better understanding of the noise sources and losses, and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight towards the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.

physics.ins-det

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM

Matrix Heater in the Gravitational Wave Observatory GEO 600

Large scale laser interferometric gravitational wave detectors (GWDs), such as GEO 600 require high quality optics to reach their design sensitivity. The inevitable surface imperfections, inhomogeneities and light-absorption induced thermal lensing in the optics can convert laser light from the fundamental mode to unwanted higher order modes, and pose challenges to the operation and sensitivity of the GWDs. Here we demonstrate the practical implementation of a thermal projection system which reduces those unwanted effects via targeted spatial heating of the optics. The thermal projector consists of 108 individually addressable heating elements which are imaged onto the beam splitter of GEO 600. We describe the optimization of the spatial heating profile and obtained results.

astro-ph.IM

Birefringence Measurements on Crystalline Silicon

Crystalline silicon has been proposed as a new test mass material in third generation gravitational wave detectors such as the Einstein Telescope (ET). Birefringence can reduce the interferometric contrast and can produce dynamical disturbances in interferometers. In this work we use the method of polarisation-dependent resonance frequency analysis of Fabry-Perot-cavities containing silicon as a birefringent medium. Our measurements show a birefringence of silicon along the (111) axis of the order of $Δ\, n \approx 10^{-7}$ at a laser wavelength of 1550nm and room temperature. A model is presented that explains the results of different settings of our measurements as a superposition of elastic strains caused by external stresses in the sample and plastic strains possibly generated during the production process. An application of our theory on the proposed ET test mass geometry suggests no critical effect on birefringence due to elastic strains.

physics.optics

Thermal Correction of Astigmatism in the Gravitational Wave Observatory GEO 600

The output port of GEO 600 is dominated by unwanted high order modes (HOMs). The current thermal actuation system, a ring heater behind one of the folding mirrors, causes a significant amount of astigmatism, which produces HOMs. We have built and installed an astigmatism correction system, based on heating this folding mirror at the sides (laterally). With these side heaters and the ring heater behind the mirror, it is possible to tune its radius of curvature in the horizontal and the vertical degree of freedom. We use this system to match the mirrors in the two arms of GEO 600 to each other, thereby reducing the contrast defect. The use of the side heaters reduces the power of the HOMs at the output of GEO 600 by approximately 37%.

physics.ins-det

Optical layout for a 10m Fabry-Pérot Michelson interferometer with tunable stability

The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible beam size. In this article we describe the optical design of a 10\,m Fabry-Pérot Michelson interferometer with tunable stability. Our design will allow us to carry out initial commissioning with arm cavities of high stability, while afterwards the arm cavity length can be increased stepwise towards the final, marginally stable configuration. Requiring only minimal hardware changes, with respect to a comparable "static" layout, the proposed technique will not only enable us to explore the stability limits of an optical resonator with realistic mirrors exhibiting inevitable surface imperfections, but also the opportunity to measure coating Brownian noise at frequencies as low as a few hundred Hertz. A detailed optical design of the tunable interferometer is presented and requirements for the optical elements are derived from robustness evaluations.

physics.optics

The upgrade of GEO600

The German / British gravitational wave detector GEO 600 is in the process of being upgraded. The upgrading process of GEO 600, called GEO-HF, will concentrate on the improvement of the sensitivity for high frequency signals and the demonstration of advanced technologies. In the years 2009 to 2011 the detector will undergo a series of upgrade steps, which are described in this paper.

gr-qc