SearcharxivSearch

arXiv subjects

Hartmut Grote

Publications and source records attributed to Hartmut Grote.

At least 19 recordsLinked to original sources

Large language models eroding science understanding: an experimental study

This paper is under review in AI and Ethics This study examines whether large language models (LLMs) can reliably answer scientific questions and demonstrates how easily they can be influenced by fringe scientific material. The authors modified custom LLMs to prioritise knowledge in selected fringe papers on the Fine Structure Constant and Gravitational Waves, then compared their responses with those of domain experts and standard LLMs. The altered models produced fluent, convincing answers that contradicted scientific consensus and were difficult for non-experts to detect as misleading. The results show that LLMs are vulnerable to manipulation and cannot replace expert judgment, highlighting risks for public understanding of science and the potential spread of misinformation.

cs.CY

Any Light Particle Searches with ALPS II: Description of the first science campaign

From February to May of 2024 the Any Light Particle Search II (ALPS II) conducted its first science campaign using the `light-shining-through-a-wall' technique to search for pseudo-Goldstone bosons that lie beyond the Standard Model of particle physics and which are inaccessible by accelerator-based experiments. The experimental setup consists of two strings of superconducting dipole magnets, each more than 100 m long, that are separated by a wall. Laser light is directed through the first magnet string and a heterodyne detection system is used to measure the electromagnetic power that traverses a wall via the conversion to and then from a bosonic field. After the wall, a high-finesse optical cavity resonantly enhances the signal power. Two searches were carried out, one with the laser polarized perpendicular to the magnetic field direction and another with its polarization state aligned parallel to the magnetic field. No evidence for the existence of new bosons was found. In its first science campaign, ALPS II reached photon-boson conversion probability sensitivities of a few $10^{-13}$. The ongoing upgrade of the optical system aims to increase this sensitivity by about four orders of magnitude.

hep-ex

Any Light Particle Searches with ALPS II: first science results

The light-shining-through-a-wall experiment ALPS II at DESY in Hamburg searched for axions and similar lightweight particles in its first science campaign from February to May 2024. No evidence for the existence of such particles was found. For pseudoscalar bosons like the axion, with masses below about 0.1 meV, we achieved a limit for the di-photon coupling strength of 1.5e-9 1/GeV at a 95% confidence level. This is more than a factor of 20 improvement compared to all previous similar experiments. We also provide limits on photon interactions for scalar, vector and tensor bosons. An achievement of this first science campaign is the demonstration of stable operation and robust calibration of the complex experiment. Currently, the optical system of ALPS II is being upgraded aiming for another two orders of magnitude sensitivity increase.

hep-ex

A Broadband Squeezed Light Source for Table-Top Interferometry

We report on the characterisation of one of two broadband squeezed light sources developed for the Quantum Enhanced Space-Time (QUEST) experiment, using balanced homodyne detection. QUEST consists of a pair of co-located, table-top, power-recycled Michelson interferometers designed to probe stationary space-time fluctuations. The interferometers are designed to be shot-noise limited in the frequency range from 1 to 200 MHz, and squeezed light will be employed with the goal to reduce the shot noise by 6 dB at frequencies inside the linewidth of the optical parametric amplifier (OPA). We directly observed up to 6.8 dB of squeezing and maintained at least 3 dB of squeezing across the full 100 MHz measurement bandwidth. After accounting for the dark noise contribution, the inferred squeezing level increased to 8.6 dB. Our squeezed light source is based on a hemilithic OPA with a 43.6 mm round-trip optical length and a linewidth of 138 MHz, making it the broadest-linewidth device to date among those suitable for long-term operation.

physics.optics

Challenges and Opportunities of Gravitational Wave Searches above 10 kHz

The first direct measurement of gravitational waves by the LIGO and Virgo collaborations has opened up new avenues to explore our Universe. This white paper outlines the challenges and gains expected in gravitational-wave searches at frequencies above the LIGO/Virgo band. The scarcity of possible astrophysical sources in most of this frequency range provides a unique opportunity to discover physics beyond the Standard Model operating both in the early and late Universe, and we highlight some of the most promising of these sources. We review several detector concepts that have been proposed to take up this challenge, and compare their expected sensitivity with the signal strength predicted in various models. This report is the summary of a series of workshops on the topic of high-frequency gravitational wave detection, held in 2019 (ICTP, Trieste, Italy), 2021 (online) and 2023 (CERN, Geneva, Switzerland).

gr-qc

Broadband limits on stochastic length fluctuations from a pair of table-top interferometers

The Quantum-Enhanced Space-Time (QUEST) experiment consists of a pair of co-located Power Recycled Michelson Interferometers, each designed to have a broadband, shot-noise limited displacement sensitivity of $2\times10^{-19}$ $\mathrm{m/\sqrt{Hz}}$ from 1 to 200 MHz. Here we present the first results of QUEST that set new upper limits on correlated length fluctuations from 13 to 80 MHz, constituting the first broadband constraints for a stochastic gravitational wave background at these frequencies. In a coincident observing run of $10^{4}$ s the averaging of the cross-correlation spectra between the two interferometer signals resulted in a strain sensitivity of $3\times10^{-20}$ $\mathrm{1/\sqrt{Hz}}$ at 40 MHz, making QUEST the most sensitive table-top interferometric system to date.

gr-qc

Design and Performance of the ALPS II Regeneration Cavity

The Regeneration Cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of $7.17 \pm 0.01$ ms, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.

physics.optics

Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit

Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.

gr-qc

Searching for scalar field dark matter with LIGO

We report on a direct search for scalar field dark matter using data from LIGO's third observing run. We analyse the coupling of size oscillations of the interferometer's beamsplitter and arm test masses that may be caused by scalar field dark matter. Using new efficient search methods to maximise sensitivity for signatures of such oscillations, we set new upper limits for the coupling constants of scalar field dark matter as a function of its mass, which improve upon bounds from previous direct searches by several orders of magnitude in a frequency band from 10 Hz to 180 Hz.

astro-ph.CO

DarkGEO: A Large-Scale Laser-Interferometric Axion Detector

Axions and axion-like particles (ALPs) are leading candidates for dark matter. They are well motivated in many extensions of the Standard Model and supported by astronomical observations. We propose an iterative transformation of the existing facilities of the gravitational-wave detector and technology testbed GEO600, located near Ruthe in Germany, into a kilometre-scale upgrade of the laser-interferometric axion detector LIDA. The final DarkGEO detector could search for coincident signatures of axions and ALPs and significantly surpass the current constraints of both direct searches and astrophysical observations in the measurement band from $10^{-16}$ to $10^{-8}$ $\text{eV}$. We discuss realistic parameters and design sensitivities for the configurations of the different iteration steps as well as technical challenges known from the first LIDA results. The proposed DarkGEO detector will be well suited to probe the parameter space associated with predictions from theoretical models, like grand-unified theories, as well as from astrophysical evidence, like the cosmic infrared background.

astro-ph.CO

Photon counting for axion interferometry

Axions and axion-like particles are well-motivated dark matter candidates. We propose an experiment that uses single photon detection interferometry to search for axions and axion-like particles in the galactic halo. We show that photon counting with a dark rate of 6E-6 Hz can improve the quantum sensitivity of axion interferometry by a factor of 50 compared to the quantum-enhanced heterodyne readout for 5-m long optical resonators. The proposed experimental method has the potential to be scaled up to kilometer-long facilities, enabling the detection or setting of constraints on the axion-photon coupling coefficient of 1E-17 - 1E-16 GeV-1 for axion masses ranging from 0.1 to 1 neV.

physics.ins-det

Characterization and evasion of backscattered light in the squeezed-light enhanced gravitational wave interferometer GEO 600

Squeezed light is injected into the dark port of gravitational wave interferometers, in order to reduce the quantum noise. A fraction of the interferometer output light can reach the OPO due to sub-optimal isolation of the squeezing injection path. This backscattered light interacts with squeezed light generation process, introducing additional measurement noise. We present a theoretical description of the noise coupling mechanism. We propose a control scheme to achieve a de-amplification of the backscattered light inside the OPO with a consequent reduction of the noise caused by it. The scheme was implemented at the GEO 600 detector and has proven to be crucial in maintaining a good level of quantum noise reduction of the interferometer for high parametric gain of the OPO. In particular, the mitigation of the backscattered light noise helped in reaching 6dB of quantum noise reduction [Phys. Rev. Lett. 126, 041102 (2021)]. The impact of backscattered-light-induced noise on the squeezing performance is phenomenologically equivalent to increased phase noise of the squeezing angle control. The results discussed in this paper provide a way for a more accurate estimation of the residual phase noise of the squeezed light field.

physics.optics

Probing dark matter with polarimetry techniques

In this work, we propose polarimetry experiments to search for low-mass (sub-eV) bosonic field dark matter, including axions and axion-like particles. We show that a polarimetry configuration consisting of a thick birefringent solid inside a Fabry-P\'erot cavity is exceptionally sensitive to scalar field dark matter, which may cause oscillatory variations in the solid's thickness and refractive index. In addition, we show that a reconfiguration of this polarimetry experiment, in which two quarter-wave plates are placed inside the Fabry-P\'erot cavity instead of a thick birefringent solid, is very sensitive to axion-like particles. We investigate the possibility of using cross-correlation of twin polarimeters to increase the sensitivity of the experiment, which in turn could allow us to explore unexplored parts of the parameter space and potentially detect a signal in either dark matter scenario.

hep-ph

Constraints on scalar field dark matter from co-located Michelson interferometers

Low-mass (sub-eV) scalar field dark matter may induce apparent oscillations of fundamental constants, resulting in corresponding oscillations of the size and the index of refraction of solids. Laser interferometers are highly sensitive to changes in the size and index of refraction of the main beamsplitter. Using cross-correlated data of the Fermilab Holometer instrument, which consists of twin co-located 40-m arm length power-recycled interferometers, we investigate the possible existence of scalar field dark matter candidates in the mass range between 1.6$\cdot$10$^{-12}$ eV and 1.0$\cdot$10$^{-7}$ eV. We set new upper limits for the coupling parameters of scalar field dark matter, improving on limits from previous direct searches by up to three orders of magnitude.

gr-qc

Optimisation of table-top 3D interferometers for Observational Quantum Gravity

With the use of twin, co-located, 3D interferometers, Cardiff University's Gravity Exploration Institute aims to observe quantum fluctuations of space-time as predicted by some theories of quantum gravity. Our design displacement sensitivity exceeds that of previous similar experiments, which have constrained the magnitudes of the fluctuations in the 1-25 MHz band. The increased sensitivity comes in large part from the comparably higher circulating power we aim to achieve, which reduces the overall shot noise. One complication of higher circulating power is an increase in contrast defect light, which includes higher-order modes. We will use the DC-readout scheme, whose dark-fringe offset must sufficiently dominate the contrast defect in order to detect faint signals. However, too much total output power risks saturating the high-bandwidth photodetectors. Suppressing the higher-order mode content of the contrast defect is a key strategy to realising the high circulating power and eliminating non-signal-carrying power that contributes to shot noise. For this, the inclusion of an output mode cleaner, whose design is described, is required.

astro-ph.IM

Direct limits for scalar field dark matter from a gravitational-wave detector

The nature of dark matter remains unknown to date; several candidate particles are being considered in a dynamically changing research landscape. Scalar field dark matter is a prominent option that is being explored with precision instruments, such as atomic clocks and optical cavities. Here we report on the first direct search for scalar field dark matter utilising a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits for the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beamsplitter of the GEO$\,$600 interferometer. The new constraints improve upon bounds from previous direct searches by more than six orders of magnitude, and are in some cases more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be probed or constrained with direct searches using gravitational-wave detectors, and highlights the potential of quantum-enhanced interferometry for dark matter detection.

gr-qc

Terrestrial Laser Interferometers

Terrestrial laser interferometers for gravitational-wave detection made the landmark first detection of gravitational waves in 2015. We provide an overview of the history of how these laser interferometers prevailed as the most promising technology in the search for gravitational waves. We describe their working principles and their limitations, and provide examples of some of the most important technologies that enabled their construction. We introduce each of the four large-scale laser interferometer gravitational-wave detectors in operation around the world today and provide a brief outlook for the future of ground-based detectors.

physics.ins-det

An Experiment for Observing Quantum Gravity Phenomena using Twin Table-Top 3D Interferometers

Theories of quantum gravity based on the holographic principle predict the existence of quantum fluctuations of distance measurements that accumulate and exhibit correlations over macroscopic distances. This paper models an expected signal due to this phenomenology, and details the design and estimated sensitivity of co-located twin table-top 3D interferometers being built to measure or constrain it. The experiment is estimated to be sensitive to displacements $\sim10^{-19}\,\rm{m}/\sqrt{\rm{Hz}}$ in a frequency band between 1 and 250 MHz, surpassing previous experiments and enabling the possible observation of quantum gravity phenomena. The experiment will also be sensitive to MHz gravitational waves and various dark matter candidates.

gr-qc