Searcharxiv⌕ Search

arXiv subjects

Hassan Yazdanian

Publications and source records attributed to Hassan Yazdanian.

6 recordsLinked to original sources

Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

eess.IV↗

A Goal-Oriented Bayesian Experimental Design to Reduce Uncertainty in Sparse-Angle X-ray Computed Tomography

Sparse-angle X-ray computed tomography (CT) presents a challenge for reliable inference, as limited measurements may leave object boundaries unresolved. Bayesian optimal experimental design (BOED) methods select informative measurements, but can be computationally expensive or require data-driven surrogates and do not explicitly exploit microlocal visibility. We address this limitation by focusing on estimating inclusion boundaries rather than the entire attenuation field. For piecewise-constant objects, these boundaries correspond to singularities characterized by their wavefront sets. Microlocal analysis determines the X-ray view-angles at which these singularities are visible. We combine this information with Bayesian uncertainty quantification to introduce B-MUSE, a microlocal uncertainty-driven sequential experimental design method. We define a microlocal C-optimality criterion associated with the wavefront direction of the most uncertain boundary singularity and prove that its optimal solution satisfies the microlocal visibility condition. B-MUSE uses this result to sequentially select informative view-angles according to boundary uncertainty. It also incorporates an adaptive stopping criterion that terminates acquisition when additional measurements provide no meaningful uncertainty reduction. We evaluate B-MUSE through numerical experiments, including interpretable examples, prior-generated inclusions, and a multi-inclusion example from an external dataset, and benchmark it against recent methods. The results show that B-MUSE substantially reduces posterior uncertainty with few adaptively selected measurements while providing boundary estimates. These findings establish a direct connection between BOED and microlocal visibility and demonstrate the potential of uncertainty-driven acquisition to reduce measurement requirements for goal-oriented X-ray CT without training data.

stat.AP↗

3D Uncertainty Quantification for Photoacoustic Tomography

Photoacoustic tomography (PAT) is a promising modality for high-resolution biomedical imaging, motivating the need for reliable uncertainty quantification (UQ) of reconstructed images. Bayesian approaches provide a rigorous framework for UQ but remain computationally challenging for realistic three-dimensional PAT and are sensitive to numerical approximations in the governing wave equation. We develop a finite-element Bayesian UQ framework for PAT that accommodates complex computational domains and detector geometries while enabling large-scale three-dimensional inference. The proposed methodology reformulates the randomize-then-optimize (RTO) sampling strategy as a matrix-free algorithm that generates independent posterior samples using only forward and adjoint wave propagations. Particular attention is given to constructing an adjoint discretization that forms an exact transpose pair with the discrete forward operator while remaining consistent with the continuous PAT adjoint, enabling efficient least-squares solvers within the sampling procedure. We investigate the influence of temporal discretization, artificial boundary conditions, and adjoint consistency on posterior uncertainty and identify discretization strategies that avoid numerical artifacts. The framework is validated against exact posterior statistics, existing Bayesian PAT methods, and Hamiltonian Monte Carlo using the No-U-Turn Sampler (NUTS), and is demonstrated on a three-dimensional problem with approximately $2\times 10^5$ unknowns on a general finite-element domain. To the best of our knowledge, this is the first large-scale Bayesian PAT study on general three-dimensional finite-element geometries, and the methodology extends naturally to a broad class of linear PDE-constrained inverse problems.

math.NA↗

Adjoint-Based Bayesian Uncertainty Quantification for PDE-Constrained Inverse Problems with Application to Semiconductor Imaging

We formulate a Bayesian framework for reconstructing doping profiles in pn-junction semiconductor devices from boundary flux measurements. The unknown doping field is modeled as a piecewise-constant function characterized by an unknown interface and two plateau concentrations, leading to a nonlinear ill-posed inverse problem governed by a Poisson-Boltzmann-type equation. To represent this structure while enabling efficient gradient-based inference, we introduce a pushforward prior constructed by mapping a latent Gaussian field with Matérn-type covariance through a sigmoid transformation. The latent field is parameterized by a truncated Karhunen-Loève expansion, while the two piecewise-constant levels are represented by scalar plateau parameters. The prior yields differentiable approximations of piecewise-constant fields with controllable interface sharpness. We establish well-posedness of the Bayesian formulation by proving Lipschitz continuity of the forward map and Hellinger stability of the posterior. We then sample the posterior using the No-U-Turn Sampler (NUTS) with gradients computed by the adjoint method. Numerical experiments show that the combination of the proposed prior and NUTS provides more efficient posterior exploration than the dimension-robust preconditioned Crank-Nicolson (pCN) sampler, yielding one to two orders of magnitude larger effective sample sizes. In the known-plateau setting, the method reconstructs both planar and curved interfaces and provides spatially resolved uncertainty quantification (UQ). When the interface geometry and plateau concentrations are inferred jointly, posterior correlations reveal structural non-identifiability. These results demonstrate the effectiveness of combining pushforward priors with adjoint-gradient-based sampling for reliable UQ in nonlinear partial differential equation-constrained inverse problems with sharp interfaces.

math.NA↗

Solving the MIT Inverse Problem by Considering Skin and Proximity Effects in Coils

This paper presents an improved technique for solving the inverse problem in magnetic induction tomography (MIT) by considering skin and proximity effects in coils. MIT is a non-contact, noninvasive, and low-cost imaging modality for obtaining the distribution of conductivity inside an object. Reconstruction of low conductivity distribution by MIT requires more accurate techniques since measured signals are inherently weak and the reconstruction problem is highly nonlinear and ill-posed. Previous MIT inverse problem studies have ignored skin and proximity effects inside coils in the forward method. In this article, the improved technique incorporates these effects in the forward method. Furthermore, it employs the regularized Gauss-Newton algorithm to reconstruct the conductivity distribution. The regularization parameter is obtained by an adaptive method using the two input parameters: a coefficient and an initial conductivity distribution. The new Jacobian matrix is computed based on a standard technique. To compare the early and improved forward methods in possible medical and industrial applications with low conductivity regions, a 2D 8-coil MIT system is modeled, and image reconstruction is performed for synthetic phantoms. Results show that it is crucial to use the improved forward method for the reconstruction of the absolute conductivity values.

physics.med-ph↗

Improved Forward Problem Modeling in Magnetic Induction Tomography for Biomedical Applications

The main contribution of this thesis is to investigate the incorporating skin and proximity effects in magnetic induction tomography (MIT) coils and present an improved model for the two-dimensional (2D) forward problem. To evaluate the performance of the improved method in possible biomedical applications, a 16 coils 2D MIT system is modeled, and the finite element method (FEM) is employed to solve the forward problem. Results show the difference between the induced voltages obtained from the early and improved method falls into the meaningful range in terms of achievable conductivity contrast from the improved one. This finding revealed the importance and necessity of using the improved forward method for modeling 2D MIT coils for biomedical applications...

physics.med-ph↗