SearcharxivSearch

arXiv subjects

Hatem Zeineldin

Publications and source records attributed to Hatem Zeineldin.

5 recordsLinked to original sources

An AI-Based Supervisory Measurement Integrity Validation Layer for Cyber-Resilient AC/DC Protection in Inverter-Based Microgrids

Line current differential relays (LCDRs) are measurement-driven relays that rely on time-synchronized multi-phase current waveforms to infer internal faults in AC and DC power networks. In inverter-based microgrids, however, the increasing reliance on digitally communicated measurements exposes LCDRs to false-data injection attacks (FDIAs), in which adversaries manipulate remote measurement streams to create protection-triggering yet physically inconsistent current trajectories. This paper addresses this emerging measurement integrity problem by introducing a measurement integrity validation scheme that operates as a supervisory instrumentation layer for modern LCDRs. The proposed scheme interprets short windows of synchronized instantaneous current measurements recorded during relay operation and assesses their physical consistency to distinguish genuine fault-induced trajectories from cyber-manipulated measurement streams. A recurrent neural network is trained offline using only relay-available current measurements and exploits the temporal structure of differential current waveforms, which remains informative in inverter-dominated systems where current magnitude is no longer a reliable observable. The method requires no additional sensors, auxiliary protection elements, or prior knowledge of network topology, and is applicable to both AC and DC LCDRs without structural modification. The proposed measurement validation scheme is evaluated on an islanded inverter-based microgrid under a comprehensive set of fault and FDIA scenarios, demonstrating high detection accuracy while preserving relay dependability. Hardware-in-the-loop validation using an OPAL-RT real-time simulator confirms that the scheme satisfies protection timing constraints and can operate in real time under realistic operating conditions.

cs.CR

Unmasking Covert Intrusions: Detection of Fault-Masking Cyberattacks on Differential Protection Systems

Line Current Differential Relays (LCDRs) are high-speed relays progressively used to protect critical transmission lines. However, LCDRs are vulnerable to cyberattacks. Fault-Masking Attacks (FMAs) are stealthy cyberattacks performed by manipulating the remote measurements of the targeted LCDR to disguise faults on the protected line. Hence, they remain undetected by this LCDR. In this paper, we propose a two-module framework to detect FMAs. The first module is a Mismatch Index (MI) developed from the protected transmission line's equivalent physical model. The MI is triggered only if there is a significant mismatch in the LCDR's local and remote measurements while the LCDR itself is untriggered, which indicates an FMA. After the MI is triggered, the second module, a neural network-based classifier, promptly confirms that the triggering event is a physical fault that lies on the line protected by the LCDR before declaring the occurrence of an FMA. The proposed framework is tested using the IEEE 39-bus benchmark system. Our simulation results confirm that the proposed framework can accurately detect FMAs on LCDRs and is not affected by normal system disturbances, variations, or measurement noise. Our experimental results using OPAL-RT's real-time simulator confirm the proposed solution's real-time performance capability.

eess.SY

Enhancing Power Quality Event Classification with AI Transformer Models

Recently, there has been a growing interest in utilizing machine learning for accurate classification of power quality events (PQEs). However, most of these studies are performed assuming an ideal situation, while in reality, we can have measurement noise, DC offset, and variations in the voltage signal's amplitude and frequency. Building on the prior PQE classification works using deep learning, this paper proposes a deep-learning framework that leverages attention-enabled Transformers as a tool to accurately classify PQEs under the aforementioned considerations. The proposed framework can operate directly on the voltage signals with no need for a separate feature extraction or calculation phase. Our results show that the proposed framework outperforms recently proposed learning-based techniques. It can accurately classify PQEs under the aforementioned conditions with an accuracy varying between 99.81%$-$91.43% depending on the signal-to-noise ratio, DC offsets, and variations in the signal amplitude and frequency.

cs.LG

Learning-Based Detection of Malicious Volt-VAr Control Parameters in Smart Inverters

Distributed Volt-Var Control (VVC) is a widely used control mode of smart inverters. However, necessary VVC curve parameters are remotely communicated to the smart inverter, which opens doors for cyberattacks. If the VVC curves of an inverter are maliciously manipulated, the attacked inverter's reactive power injection will oscillate, causing undesirable voltage oscillations to manifest in the distribution system, which, in turn, threatens the system's stability. In contrast with previous works that proposed methods to mitigate the oscillations after they are already present in the system, this paper presents an intrusion detection method to detect malicious VVC curves once they are communicated to the inverter. The proposed method utilizes a Multi-Layer Perceptron (MLP) that is trained on features extracted from only the local measurements of the inverter. After a smart inverter is equipped with the proposed method, any communicated VVC curve will be verified by the MLP once received. If the curve is found to be malicious, it will be rejected, thus preventing unwanted oscillations beforehand. Otherwise, legitimate curves will be permitted. The performance of the proposed scheme is verified using the 9-bus Canadian urban benchmark distribution system simulated in PSCAD/EMTDC environment. Our results show that the proposed solution can accurately detect malicious VVC curves.

eess.SY

Exact BER Performance Analysis for Downlink NOMA Systems Over Nakagami-m Fading Channels

In this paper, the performance of a promising technology for the next generation wireless communications, non-orthogonal multiple access (NOMA), is investigated. In particular, the bit error rate (BER) performance of downlink NOMA systems over Nakagami-m flat fading channels, is presented. Under various conditions and scenarios, the exact BER of downlink NOMA systems considering successive interference cancellation (SIC) is derived. The transmitted signals are randomly generated from quadrature phase shift keying (QPSK) and two NOMA systems are considered; two users' and three users' systems. The obtained BER expressions are then used to evaluate the optimal power allocation for two different objectives, achieving fairness and minimizing average BER. The two objectives can be used in a variety of applications such as satellite applications with constrained transmitted power. Numerical results and Monte Carlo simulations perfectly match with the derived BER analytical results and provide valuable insight into the advantages of optimal power allocation which show the full potential of downlink NOMA systems.

cs.IT