Searcharxiv⌕ Search

arXiv subjects

Heiko Tzschätzsch

Publications and source records attributed to Heiko Tzschätzsch.

3 recordsLinked to original sources

Masked Registration and Autoencoding of CT Images for Predictive Tibia Reconstruction

Surgical planning for complex tibial fractures can be challenging for surgeons, as the 3D structure of the later desirable bone alignment may be difficult to imagine. To assist in such planning, we address the challenge of predicting a patient-specific reconstruction target from a CT of the fractured tibia. Our approach combines neural registration and autoencoder models. Specifically, we first train a modified spatial transformer network (STN) to register a raw CT to a standardized coordinate system of a jointly trained tibia prototype. Subsequently, various autoencoder (AE) architectures are trained to model healthy tibial variations. Both the STN and AE models are further designed to be robust to masked input, allowing us to apply them to fractured CTs and decode to a prediction of the patient-specific healthy bone in standard coordinates. Our contributions include: i) a 3D-adapted STN for global spatial registration, ii) a comparative analysis of AEs for bone CT modeling, and iii) the extension of both to handle masked inputs for predictive generation of healthy bone structures. Project page: https://github.com/HongyouZhou/repair

cs.CV↗

Optical time-harmonic elastography for multiscale stiffness mapping across the phylogenetic tree

Rapid mapping of the mechanical properties of soft biological tissues from light microscopy to macroscopic imaging could transform fundamental biophysical research by providing clinical biomarkers to complement in vivo elastography. We here introduce superfast optical time-harmonic elastography (OTHE) to remotely encode surface and subsurface shear wave fields for generating maps of tissue stiffness with unprecedented detail resolution. OTHE rigorously exploits the space-time propagation characteristics of time-harmonic waves to address current limitations of biomechanical imaging and elastography. Key solutions are presented for stimulation, encoding, and stiffness reconstruction of time-harmonic, multifrequency shear waves, all tuned to provide consistent stiffness values across resolutions from microns to millimeters. OTHE's versatility is demonstrated in Bacillus subtilis biofilms, zebrafish embryos, adult zebrafish, and human skeletal muscle, reflecting the diversity of the phylogenetic tree from a mechanics perspective. By zooming in on stiffness details from coarse to finer scales, OTHE advances developmental biology and offers a way to perform biomechanics-based tissue histology that consistently matches in vivo time-harmonic elastography in patients.

physics.bio-ph↗

Liquid-liver phantom: mimicking the viscoelastic dispersion of human liver for elastography in ultrasound and MRI

Different clinical elastography devices show different liver-stiffness values in the same subject, hindering comparison of values and establishment of system-independent thresholds for disease detection. Therefore, authorities request standardized phantoms that address the viscosity-related dispersion of stiffness over frequency. A linear polymerized polyacrylamide phantom (PAAm) was calibrated to the viscoelastic properties of healthy human liver in vivo. Shear-wave speed as a surrogate of stiffness was quantified between 5 Hz and 3000 Hz frequency-range by shear rheometry, ultrasound-based time-harmonic elastography, clinical MR elastography (MRE), and tabletop MRE. Imaging parameters for ultrasound were close to those of liver in vivo. Reproducibility, aging behavior and temperature dependency were assessed and fulfilled requirements for quantitative elastography. In addition, the phantom was used to characterize the frequency bandwidth of shear-wave speed of several clinical elastography methods. The liquid-liver phantom has favorable properties for standardization and development of liver elastography: first, it can be used across clinical and experimental elastography devices in ultrasound and MRI. Second, being a liquid, it can easily be adapted in size and shape to specific technical requirements, and by adding inclusions and scatterers. Finally, since the phantom is based on non-crosslinked linear PAA constituents, it is easy to produce, indicating potential widespread use among researchers and vendors to standardize liver-stiffness measurements.

physics.bio-ph↗