Helge Herthum

Publications and source records attributed to Helge Herthum.

4 recordsLinked to original sources

Shimmer: End-to-End Open-Source Passive B0 Shimming Methodology for Low-Field MRI Magnets

Low-field MRI scanners based on permanent magnet arrays require accurate B0 shimming to achieve sufficient field homogeneity for imaging. Here, we present Shimmer, an open-source methodology for passive shimming of low-field MRI magnets using additional NdFeB magnets placed outside the main magnet array. The end-to-end methodology combines magnetic field mapping, magnetic field simulations, numerical optimization of shim magnet positions and orientations, and automated generation of 3D-printable shim holders. Continuous magnet rotations and several optimization strategies are considered and evaluated. The method was validated and applied to three different permanent magnet arrays ~50 mT in 200 mm diameter spherical volumes, reducing initial field inhomogeneities of 9361ppm, 31721 ppm and 34143 ppm to 888 ppm, 1812 ppm and 1602 ppm respectively. The improved homogeneity enabled undistorted MR imaging of a phantom. Shimmer provides a reproducible and adaptable approach for improving the performance of low-field MRI magnets.

physics.med-ph

A Reference System for Open Source Portable Low-Field MRI

Despite its renewed attention, the pathway to point-of-care portable low-field MRI systems remains challenging, limiting adoption across research groups. Incomplete documentation limits reproducibility, causing redesign and complicating cross-system comparison. Moreover, non-standardized testing and characterization complicates ethical approval for clinical studies. We present an open-source reference system for portable low-field MRI designed to support replication, reproducibility, benchmarking, and quantitative comparison. The system is fully open source, based on a ~50 mT permanent magnet, and integrated with a cloud-native acquisition platform. Pulseq-based calibration, characterization, and imaging sequences assessed noise level, eddy currents, image-based SNR, and geometric accuracy. Quantitative T1, T2, and B0 mapping sequences were developed and evaluated against reference values. Initial results from independent replications at two sites were compared. The system reached a noise level of 1.4 relative to the thermal noise floor and short eddy-current decay constants of 27-32 us across all gradient channels. Geometric deviations were below 2 mm over the field of view. Image-based SNR were consistent between the independent replications. Measured T1 values closely matched specified values, with an average absolute error of 3.1(1.8)%, while T2 values were overestimated by 10.4(5.8)%. Simulations showed only marginal errors for both quantities, suggesting experimental error sources for T2 mapping. The reference system combines openly documented hardware, software, calibration procedures, phantoms, quantitative MRI, and simulation tools in a reproducible ecosystem, aiming to support cross-site comparability, reproducible research, and collaborative development of future portable low-field MRI technologies.

physics.med-ph

In Vivo Wideband MR Elastography for Assessing Age-Related Viscoelastic Changes of the Human Brain

Magnetic Resonance Elastography (MRE) noninvasively maps brain biomechanics and is highly sensitive to alterations associated with aging and neurodegenerative disease. Most implementations use a single frequency or a narrow frequency band, limiting the analysis of frequency-dependent viscoelastic parameters. We developed a dual-actuator wideband MRE (5-50 Hz) protocol and acquired wavefields at 13 frequencies in 24 healthy adults (young: 23-39 years; older: 50-63 years). Shear wave speed (SWS) maps were generated as a proxy for stiffness, and SWS dispersion was modeled using Newtonian, Kelvin-Voigt, and power-law rheological models. Whole-brain stiffness declined with age, with the strongest effect observed at low frequencies (5-16 Hz: -0.24%/year; p=0.019) compared with mid (20-35 Hz: -0.12%/year; p=0.030) and high frequencies (40-50 Hz: -0.10%/year; p=0.165). Compared to older brains, younger adults showed 14.3% higher baseline stiffness in the power-law model (p=0.001) and 8.5-9.0% higher viscosity according to the Newtonian and Kelvin-Voigt model (p<0.05). White and cortical gray matter exhibited similar age-related decreases, while deep gray matter showed an increase in the power-law exponent (+0.001/year; p=0.036), suggesting a transition toward more fluid-like properties associated with aging. Wideband MRE revealed frequency-dependent and region-specific biomechanical alterations with aging, with the strongest effects observed at low frequencies. Extending brain MRE into the low frequency regime potentially enhances sensitivity to solid-fluid interactions. Therefore, low frequency MRE may serve as an early biomechanical marker of microstructural brain changes due to aging and neurodegeneration.

physics.med-ph

Liquid-liver phantom: mimicking the viscoelastic dispersion of human liver for elastography in ultrasound and MRI

Different clinical elastography devices show different liver-stiffness values in the same subject, hindering comparison of values and establishment of system-independent thresholds for disease detection. Therefore, authorities request standardized phantoms that address the viscosity-related dispersion of stiffness over frequency. A linear polymerized polyacrylamide phantom (PAAm) was calibrated to the viscoelastic properties of healthy human liver in vivo. Shear-wave speed as a surrogate of stiffness was quantified between 5 Hz and 3000 Hz frequency-range by shear rheometry, ultrasound-based time-harmonic elastography, clinical MR elastography (MRE), and tabletop MRE. Imaging parameters for ultrasound were close to those of liver in vivo. Reproducibility, aging behavior and temperature dependency were assessed and fulfilled requirements for quantitative elastography. In addition, the phantom was used to characterize the frequency bandwidth of shear-wave speed of several clinical elastography methods. The liquid-liver phantom has favorable properties for standardization and development of liver elastography: first, it can be used across clinical and experimental elastography devices in ultrasound and MRI. Second, being a liquid, it can easily be adapted in size and shape to specific technical requirements, and by adding inclusions and scatterers. Finally, since the phantom is based on non-crosslinked linear PAA constituents, it is easy to produce, indicating potential widespread use among researchers and vendors to standardize liver-stiffness measurements.

physics.bio-ph