SearcharxivSearch

arXiv subjects

Hen-Wei Huang

Publications and source records attributed to Hen-Wei Huang.

13 recordsLinked to original sources

Reevaluating Bluetooth Low Energy for Ingestible Electronics

Bluetooth Low Energy (BLE) is widely used in wearable devices but has rarely been considered for ingestible electronics because of severe tissue attenuation at 2.4 GHz. In this work, we systematically reevaluate BLE for ingestible applications by benchmarking it against representative Sub-GHz schemes in terms of tissue attenuation, power consumption, throughput, reliability, bidirectional communication, latency, and system integration. Water-phantom and in vivo measurements confirm stronger attenuation at 2.4 GHz, by approximately 40 dB; however, front-end-module (FEM)-assisted BLE compensates for this loss while maintaining practical received signal levels and energy efficiency. For ingestible sensing applications requiring below 100 kbps, BLE with a 20 dBm transmission power achieves lower power consumption than the evaluated Sub-GHz alternatives. BLE also provides protocol-level reliability through retransmission and in-order packet delivery, whereas Sub-GHz links can suffer packet loss under high attenuation. In addition, BLE supports bidirectional communication with limited throughput degradation, while the evaluated Sub-GHz implementation shows a substantial reduction. End-to-end measurements further demonstrate lower BLE latency because of its native compatibility with modern computing infrastructure. Finally, BLE offers advantages in antenna form factor, ecosystem support, and system integration. These results demonstrate that properly configured BLE is a practical communication solution for next-generation ingestible electronics.

eess.SY

Dual IMU System for Accurate Gastrointestinal Motility Tracking

Gastrointestinal (GI) motility disorders impair the coordinated movement of food through the digestive tract. The Wireless Motility Capsule was developed to indirectly assess GI motility by recording pressure, pH, and temperature along the GI tract. Although an inertial measurement unit (IMU) enables precise and direct motion tracking, a single-IMU system is highly susceptible to artifacts caused by body movement and respiration. To address this limitation, we propose a dual-IMU system designed to distinguish intrinsic GI motility from extrinsic body motion. One IMU is integrated into an ingestible capsule to monitor internal movement, while a second IMU is worn externally to capture whole-body dynamics. Experimental validation was conducted using a turntable to simulate random body movements and a Stewart platform oscillating at 0.1 Hz to emulate GI motility. Three sensor fusion algorithms, including the Extended Kalman Filter, Madgwick Filter, and Mahony Filter, were benchmarked to calculate the real-time relative orientation between the two IMUs using quaternion analysis. The results show that the dual-IMU system effectively differentiates platform motion from turntable motion, demonstrating its potential to isolate GI-specific motility. Pearson correlation coefficients greater than 0.8 between the baseline and noise-cancelled motility signals indicate strong agreement and effective noise suppression.

eess.SP

Enhanced-BLE: A Hybrid BLE-ESB Framework for Dynamically Reconfigurable and Energy-Efficient 2.4 GHz IoT Communication

Bluetooth Low Energy (BLE) is widely used in IoT systems because of its low power consumption, interoperability, and reliable bidirectional communication. However, its connection-oriented architecture introduces trade-offs among wake-up latency, throughput, and energy efficiency, limiting its suitability for burst-mode and on-demand sensing applications. Enhanced ShockBurst (ESB), a lightweight connectionless protocol supported by the same 2.4 GHz Nordic Semiconductor hardware, enables fast wake-up and efficient data transmission, but does not provide BLE-level robustness for sustained bidirectional communication. This work systematically benchmarks BLE and ESB on a unified Nordic nRF54L15 platform and proposes Enhanced-BLE, a hybrid framework that integrates the two protocols to extend conventional BLE operation. Experimental results show that ESB nearly halves packet transmission time and energy compared with BLE, doubles the achievable forward throughput, and reduces wake-up latency and energy by nearly twentyfold during intermittent operation. However, ESB reverse transmission may suffer packet loss, whereas BLE maintains reliable bidirectional communication. Enhanced-BLE addresses this trade-off through adaptive radio scheduling and coexistence-aware connection management, combining ESB-based high-throughput forward transmission with BLE-based reliable reverse communication. The framework enables BLE-to-ESB handover within approximately 18 ms and restores BLE operation within 49 ms from standby mode. Enhanced-BLE also achieves approximately twofold higher forward throughput than BLE while reducing wake-up latency. These results demonstrate a practical and hardware-compatible strategy for low-latency, high-throughput, energy-efficient, and reliable 2.4 GHz IoT communication.

cs.NI

BiFedKD: Bidirectional Federated Knowledge Distillation Framework for Non-IID and Long-Tailed ECG Monitoring

Electrocardiogram (ECG) monitoring in Internet of Medical Things (IoMT) networks is constrained by strict data-sharing regulations and privacy concerns. Federated learning (FL) enables collaborative learning by keeping raw ECG data on devices, but frequent transmissions of high-dimensional model updates incur heavy per-round traffic over bandwidth-limited links. To alleviate this bottleneck, federated distillation (FD) replaces parameter exchange with logit-based knowledge transfer. However, the performance of FD often degrades under the non-independent and identically distributed (non-IID) and long-tailed label distributions in ECG deployments. To address these challenges, we propose a bidirectional federated knowledge distillation (BiFedKD) framework that employs an aggregation-by-distillation pipeline with temperature scaling to produce a stable global distillation signal for cross-client alignment. Experiments on the MIT-BIH Arrhythmia dataset show that BiFedKD improves accuracy and Macro-F1 over the baseline by $3.52\%$ and $9.93\%$, respectively. Moreover, to reach the same Macro-F1, BiFedKD reduces communication overhead by $40\%$ and computation cost by $71.7\%$ compared with the baseline.

cs.AI

Kirigami-Structured Electronic Capsule for Long-Term Continuous Gastric Monitoring

Ingestible electronic systems enable non-invasive, in situ sensing within the gastrointestinal (GI) tract, yet clinical translation has been limited by uncontrolled transit, short operational lifetimes, and unreliable wireless communication that prevent continuous monitoring. Here, we present a gastric-resident ingestible robotic platform that achieves week-long operation through integration of a bioinspired, electrically triggered release mechanism with a kirigami-enabled electronic architecture. A kirigami-patterned flexible printed circuit board spans the capsule body and deployable superelastic arms, enabling high-density integration of sensing, power management, and wireless modules within a constrained volume while tolerating large mechanical deformation during gastric residence. Stable retention and on-demand disassembly are achieved using thermally responsive polycaprolactone joints that transition from rigid to compliant states under electrical activation, avoiding dependence on variable chemical triggers. Reliable telemetry in the highly attenuating gastric environment is maintained using a dual-band Bluetooth Low Energy and sub-gigahertz module with RSSI- and throughput-aware adaptive transmission, balancing link robustness and energy consumption. We demonstrate long-term, continuous monitoring of gastric radiation exposure, enabling early detection of dose accumulation and providing a promising in vivo alternative to wearable or handheld dosimeters. Swine studies confirm stable gastric residence, sustained real-time telemetry, and safe gastrointestinal passage following triggered disassembly. This work establishes kirigami-enabled integration as a scalable strategy for long-term gastric-resident robotic systems.

eess.SY

SGC-RML: A reliable and interpretable longitudinal assessment for PD in real-world DNS

Real-world digital Parkinson's disease assessment faces challenges such as heterogeneous modalities, cross-device bias, and incomplete labeling. Existing methods often focus on average predictive performance, lacking the reliability mechanisms needed for retrospective reliability-aware assessment - namely, determining when the model is reliable, when to reject an assessment, when to retest, and from which symptom dimensions the predictions are based. This paper proposes SGC-RML, which maps speech, gait, wearable motion, mobility tasks, and clinical variables to a shared 8-dimensional symptom node space (7 clinical symptom nodes and 1 reliability_state auxiliary node), unifying motor and non-motor representations through a symptom atlas. By jointly introducing uncertainty estimation, conformal calibration, and selective decision routing, the model can not only predict symptoms and severity but also reject assessments or suggest retests when evidence is insufficient. We validate this framework on five real-world PD datasets, covering classification, regression, event detection, and longitudinal severity prediction. Experiments show that SGC-RML achieves an MAE of 4.579 / R^2 of 0.772 on PPMI, an AUC of 0.953 on mPower, and an AUC of 0.825 on PADS. Under leak-free temporal anchoring, as few as 5 subject-specific anchors transform UCI from an essentially non-predictive subject-independent setting (motor MAE 8.38, CCC 0.02) into a calibrated longitudinal assessment (motor MAE 3.24, CCC 0.756) with split-conformal coverage held at the 0.80 target. Under the Daphnet LOSO protocol, it achieves an F1 of 0.803 / AUC of 0.872. These results demonstrate that SGC-RML provides a unified paradigm for accurate, calibrated, auditable, and symptom-interpretable retrospective longitudinal assessment of PD under incomplete multimodal conditions.

cs.LG

Real-Time Minimum-Energy Operating-Point Tracking for Battery-Powered Micro DC Motors Under Dynamically Variable Loading

Micro DC brushed motors are widely deployed in battery-powered biomedical systems, where limited energy budgets and variable physiological loading impose stringent efficiency and safety constraints. However, conventional actuation strategies rely on conservative voltage margins to avoid stalling, leading to systematic energy inefficiency. Furthermore, existing methods primarily optimize steady-state performance, neglecting the energy required to complete individual actuation cycles under dynamic conditions. This paper reveals that the energy consumption per mechanical cycle of a DC motor exhibits a non-monotonic dependence on driving voltage, with a load-dependent minimum that shifts with external loading. Based on this insight, we propose a real-time operating-point tracking method that enables the motor to autonomously converge to its minimum-energy condition. A lightweight load metric derived from current waveform features is introduced to detect load variation, and a two-phase adaptive voltage strategy is developed to track the optimal operating point online. Experimental results demonstrate that the proposed method can track the new minimum-energy operating region under both low-to-high and high-to-low loading transitions. With 3-cycle averaging, the mean response time is 11.55s for the low-to-high case and 11.16s for the high-to-low case, while the mean convergence voltage is 2.73V and 2.0V, respectively.

eess.SY

Enhanced ShockBurst for Ultra Low-Power On-Demand Sensing

On demand sensing is emerging as a key paradigm in Internet of Things (IoT) systems, where devices remain in low power states and transmit data only upon event triggers. Such an operation requires wireless communication schemes that provide low latency, minimal wake up overhead, and high energy efficiency. However, widely adopted protocols such as Bluetooth Low Energy (BLE) rely on connection oriented mechanisms that incur non negligible latency and energy overhead during sleep wake transitions, limiting their effectiveness for event driven sensing. In this work, Nordic Semiconductor's proprietary Enhanced ShockBurst (ESB) protocol is investigated as an alternative communication scheme for low power on demand IoT systems. A systematic experimental comparison between ESB and BLE is presented on the same hardware platform, evaluating packet level latency, transmission energy, achievable throughput, wake up overhead under duty cycled operation, and bidirectional communication characteristics. Results show that ESB achieves a packet latency of 0.68 ms for a 244 byte payload, reduces per packet transmission time and energy by nearly 2x, increases maximum throughput by approximately 2x, and lowers wake up time and energy by up to 10x compared with BLE. To demonstrate system level impact, an implantable loop recorder prototype with FIFO triggered electrocardiogram transmission is implemented. The ESB based system enables rapid event driven communication with a minimum communication power of 0.5 mW and reduces total system power consumption by approximately 60 percent relative to BLE. These results highlight the limitations of connection oriented protocols for on demand sensing and establish ESB as a lightweight and effective communication alternative for energy constrained IoT applications, including biomedical implants and event driven monitoring systems.

eess.SY

Multiprotocol Wireless Timer Synchronization for IoT Systems

Accurate time synchronization is essential for Internet of Things (IoT) systems, where multiple distributed nodes must share a common time base for coordinated sensing and data fusion. However, conventional synchronization approaches suffer from nondeterministic transmission latency, limited precision, or restricted bidirectional functionality. This paper presents a protocol-independent wireless timer synchronization method that exploits radio timeslots to transmit precisely timestamped beacons in a proprietary radio mode. By decoupling synchronization from upper-layer packet retransmissions and leveraging hardware-timed radio events, the proposed approach significantly reduces scheduling uncertainty and achieves nanosecond-level synchronization accuracy. Comprehensive experiments evaluate the impacts of synchronization frequency, RSSI, BLE connection interval, and throughput on synchronization performance. The results demonstrate that an optimal synchronization frequency of 1000 Hz yields an approximately 20 ns delay in the absence of communication stack activity while maintaining sub-500 ns accuracy under most realistic BLE traffic conditions. Furthermore, larger connection intervals, lower application throughput, and higher RSSI consistently improve synchronization quality by reducing radio resource contention and packet loss. The proposed scheme provides a general and high-precision synchronization solution suitable for resource-constrained IoT systems.

cs.NI

A Hybrid BLE-Wi-Fi Communication Architecture for Adaptive Imaging in Wireless Capsule Endoscopy

Wireless capsule endoscopy (WCE) is fundamentally constrained by limited wireless bandwidth, resulting in low imaging resolution and frame rate, which can cause motion blur and missed lesions. Although adaptive frame-rate schemes have been explored to accommodate transient gastrointestinal (GI) motility, these approaches typically require sacrificing image resolution. The use of higher-frequency communication bands is further limited by increased tissue attenuation. To address these challenges, we propose a hybrid Bluetooth Low Energy (BLE) and WiFi communication architecture that combines the low-power operation of BLE with the high data throughput of WiFi. We systematically evaluate the performance of BLE and WiFi under tissue-mimicking conditions by measuring throughput, received signal strength indicator (RSSI), and power consumption. The results demonstrate that amplified BLE with an adaptive transmission power control strategy provides a stable frame rate at low power consumption, while 2.4 GHz WiFi operating in station mode is the most suitable high-throughput communication configuration for WCE. Compared with WiFi, BLE reduces power consumption by approximately ten times, whereas WiFi achieves up to ten times higher throughput. To reconcile these complementary trade-offs, we further introduce a hybrid system with a frame-boundary-synchronized switching mechanism to ensure lossless data transmission during BLE and WiFi transitions. Experimental results show that the switching latency from BLE to WiFi is approximately 92.66 ms, which is longer than the WiFi-to-BLE switching latency of 15.49 ms when transmitting 10 kB image payloads. Overall, the proposed hybrid BLE and WiFi system enables robust, lossless, and energy-efficient mode switching, supports adaptive imaging, and advances the development of next-generation autonomous WCE platforms.

eess.SY

A Capsule-Sized Multi-Wavelength Wireless Optical System for Edge-AI-Based Classification of Gastrointestinal Bleeding Flow Rate

Post-endoscopic gastrointestinal (GI) rebleeding frequently occurs within the first 72 hours after therapeutic hemostasis and remains a major cause of early morbidity and mortality. Existing non-invasive monitoring approaches primarily provide binary blood detection and lack quantitative assessment of bleeding severity or flow dynamic, limiting their ability to support timely clinical decision-making during this high-risk period. In this work, we developed a capsule-sized, multi-wavelength optical sensing wireless platform for order-of-magnitude-level classification of GI bleeding flow rate, leveraging transmission spectroscopy and low-power edge artificial intelligence. The system performs time-resolved, multi-spectral measurements and employs a lightweight two-dimensional convolutional neural network for on-device flow-rate classification, with physics-based validation confirming consistency with wavelength-dependent hemoglobin absorption behavior. In controlled in vitro experiments under simulated gastric conditions, the proposed approach achieved an overall classification accuracy of 98.75% across multiple bleeding flow-rate levels while robustly distinguishing diverse non-blood gastrointestinal interference. By performing embedded inference directly on the capsule electronics, the system reduced overall energy consumption by approximately 88% compared with continuous wireless transmission of raw data, making prolonged, battery-powered operation feasible. Extending capsule-based diagnostics beyond binary blood detection toward continuous, site-specific assessment of bleeding severity, this platform has the potential to support earlier identification of clinically significant rebleeding and inform timely re-intervention during post-endoscopic surveillance.

eess.IV

Closed-Loop Transmission Power Control for Reliable and Low-Power BLE Communication in Dynamic IoT Settings

Reliable and energy-efficient Bluetooth Low Energy (BLE) communication is crucial for Internet of Things (IoT) applications in dynamic environments. However, the Received Signal Strength Indicator (RSSI) and data throughput in BLE are highly susceptible to environmental variability, which degrades communication performance. In this work, we systematically analyze the interdependence among RSSI, throughput, transmission power (TXP), and the peripheral device system power consumption under diverse real-world conditions. We observe that adjusting the TXP effectively influences both RSSI and throughput. We propose a robust closed-loop TXP control framework based on Proportional-Integral-Derivative (PID) controllers. Two initial control strategies are investigated: an RSSI-based approach and a throughput-based approach, each exhibiting distinct advantages and limitations. The RSSI-based method provides rapid responsiveness to signal fluctuations but lacks direct correlation with data throughput, whereas the throughput-based method offers more accurate feedback on effective throughput at the cost of slower response. To address these limitations, a hybrid RSSI-throughput control strategy is developed, combining the responsiveness of RSSI feedback with the accuracy of throughput measurements. Experimental results demonstrate that the proposed hybrid approach maintains data throughput close to the target level with minimal variance, even under rapidly changing environmental conditions.

eess.SY

Pretraining ECG Data with Adversarial Masking Improves Model Generalizability for Data-Scarce Tasks

Medical datasets often face the problem of data scarcity, as ground truth labels must be generated by medical professionals. One mitigation strategy is to pretrain deep learning models on large, unlabelled datasets with self-supervised learning (SSL). Data augmentations are essential for improving the generalizability of SSL-trained models, but they are typically handcrafted and tuned manually. We use an adversarial model to generate masks as augmentations for 12-lead electrocardiogram (ECG) data, where masks learn to occlude diagnostically-relevant regions of the ECGs. Compared to random augmentations, adversarial masking reaches better accuracy when transferring to to two diverse downstream objectives: arrhythmia classification and gender classification. Compared to a state-of-art ECG augmentation method 3KG, adversarial masking performs better in data-scarce regimes, demonstrating the generalizability of our model.

cs.LG