SearcharxivSearch

arXiv subjects

Hengjie Liu

Publications and source records attributed to Hengjie Liu.

13 recordsLinked to original sources

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

eess.IV

Anisotropic Electronic Correlations in the Spin Density Wave State of La$_3$Ni$_2$O$_7$

The bilayer nickelate superconductor La$_3$Ni$_2$O$_7$ undergoes a density wave transition near 150 K that has attracted intensive scrutiny, yet its microscopic origin remains elusive. Here we report polarization-resolved electronic Raman scattering measurements on high-quality single crystals of La$_3$Ni$_2$O$_7$. Below 150\,K, we observe a pronounced, symmetry-dependent redistribution of spectral weight in B$_{1g}$ and B$_{2g}$ channels, consistent with the formation of spin-density-wave (SDW) gaps. Quantitative analysis reveals momentum-selective SDW gap amplitudes, with intermediate-to-strong coupling near X/Y points of the Brillouin zone and weaker coupling along the diagonal direction, indicating an unconventional SDW driven by anisotropic electronic correlations. Our results establish the electronic character of the SDW in La$_3$Ni$_2$O$_7$, and provide a microscopic foundation for understanding the emergence of high-temperature superconductivity under pressure in nickelates.

cond-mat.supr-con

Unconventional Pressure Evolution of Spin-Density-Wave State in La$_{3}$Ni$_{2}$O$_{7}$

The discovery of pressure-induced high temperature superconductivity in the bilayer nickelate La$_{3}$Ni$_{2}$O$_{7}$ has raised the question of how its spin-density-wave (SDW) state evolves toward the superconducting regime. Here, we report a systematic electronic Raman study of La$_{3}$Ni$_{2}$O$_{7}$ single crystals under hydrostatic pressures up to 16.51 GPa. Both the SDW gap energy and the transition temperature $T_{\mathrm{SDW}}$ show an overall increase with pressure, while the dimensionless coupling ratio 2$Δ_{\text{SDW}}/(k_{\text{B}}T_{\text{SDW}})$ remains constant around $\sim7.5$, indicating a robust strong-coupling character of SDW state. At the same time, the Raman SDW peak broadens as pressure is applied, indicating a gradual weakening of long-range SDW order. These results reveal an unusual pressure evolution in which the SDW energy scale is enhanced while the SDW state becomes progressively less coherent, providing spectroscopic constraints on the magnetic correlations relevant to superconductivity in bilayer nickelates.

cond-mat.supr-con

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

cs.CV

Precise Verification of Transformers through ReLU-Catalyzed Abstraction Refinement

Formal verification of transformers has become increasingly important due to their widespread deployment in safety-critical applications. Compared to classic neural networks, the inferences of transformers involve highly complex computations, such as dot products in self-attention layers, rendering their verification extremely difficult. Existing approaches explored over-approximation methods by constructing convex constraints to bound the output ranges of transformers, which can achieve high efficiency. However, they may sacrifice verification precision, and consequently introduce significant approximation error that leads to frequent occurrences of false alarms. In this paper, we propose a transformer verification approach that can achieve improved precision. At the core of our approach is a novel usage of ReLU, by which we represent a precise but non-linear bound for dot products such that we can further exploit the rich body of literature for convex relaxation of ReLU to derive precise bounds. We extend two classic approaches to the context of transformers, a rule-based one and an optimization-based one, resulting in two new frameworks for efficient and precise verification. We evaluate our approaches on different model architectures and robustness properties derived from two datasets about sentiment analysis, and compare with the state-of-the-art baseline approach. Compared to the baseline, our approach can achieve significant precision improvement for most of the verification tasks with acceptable compromise of efficiency, which demonstrates the effectiveness of our approach.

cs.AI

B-FIRE: Binning-Free Diffusion Implicit Neural Representation for Hyper-Accelerated Motion-Resolved MRI

Accelerated dynamic volumetric magnetic resonance imaging (4DMRI) is essential for applications relying on motion resolution. Existing 4DMRI produces acceptable artifacts of averaged breathing phases, which can blur and misrepresent instantaneous dynamic information. Recovery of such information requires a new paradigm to reconstruct extremely undersampled non-Cartesian k-space data. We propose B-FIRE, a binning-free diffusion implicit neural representation framework for hyper-accelerated MR reconstruction capable of reflecting instantaneous 3D abdominal anatomy. B-FIRE employs a CNN-INR encoder-decoder backbone optimized using diffusion with a comprehensive loss that enforces image-domain fidelity and frequency-aware constraints. Motion binned image pairs were used as training references, while inference was performed on binning-free undersampled data. Experiments were conducted on a T1-weighted StarVIBE liver MRI cohort, with accelerations ranging from 8 spokes per frame (RV8) to RV1. B-FIRE was compared against direct NuFFT, GRASP-CS, and an unrolled CNN method. Reconstruction fidelity, motion trajectory consistency, and inference latency were evaluated.

cs.CV

Zero-shot Multi-Contrast Brain MRI Registration by Intensity Randomizing T1-weighted MRI (LUMIR25)

In this paper, we present our submission to the LUMIR25 task of Learn2Reg 2025, which ranked 1st overall on the test set. Extended from LUMIR24, this year's task focuses on zero-shot registration under domain shifts (e.g., high-field MRI, pathological brains, and various MRI contrasts), while the training data comprises only in-domain T1-weighted brain MRI. We start with a meticulous analysis of LUMIR24 winners to identify the main contributors to strong monomodal registration performance. We highlight the importance of registration-specific inductive biases, including multi-resolution pyramids, inverse and group consistency, topological preservation or diffeomorphism, and correlation-based correspondence establishment. To further generalize to diverse contrasts, we employ three simple but effective strategies: (i) a multimodal loss based on the modality-independent neighborhood descriptor (MIND), (ii) intensity randomization for unseen contrast augmentation, and (iii) lightweight instance-specific optimization (ISO) on feature encoders at inference time. On the validation set, the proposed approach substantially improves T1-T2 registration accuracy, demonstrating robust cross-contrast generalization without relying on explicit image synthesis. These results suggest a practical step toward a registration foundation model that can leverage a single training domain yet remain robust across domain shifts.

eess.IV

Accelerated Patient-specific Non-Cartesian MRI Reconstruction using Implicit Neural Representations

The scanning time for a fully sampled MRI can be undesirably lengthy. Compressed sensing has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is computationally complex and difficult to generalize on new cases. Image-domain-based deep learning methods (e.g., convolutional neural networks) emerged as a faster alternative but face challenges in modeling continuous k-space, a problem amplified with non-Cartesian sampling commonly used in accelerated acquisition. In comparison, implicit neural representations can model continuous signals in the frequency domain and thus are compatible with arbitrary k-space sampling patterns. The current study develops a novel generative-adversarially trained implicit neural representations (k-GINR) for de novo undersampled non-Cartesian k-space reconstruction. k-GINR consists of two stages: 1) supervised training on an existing patient cohort; 2) self-supervised patient-specific optimization. In stage 1, the network is trained with the generative-adversarial network on diverse patients of the same anatomical region supervised by fully sampled acquisition. In stage 2, undersampled k-space data of individual patients is used to tailor the prior-embedded network for patient-specific optimization. The UCSF StarVIBE T1-weighted liver dataset was evaluated on the proposed framework. k-GINR is compared with an image-domain deep learning method, Deep Cascade CNN, and a compressed sensing method. k-GINR consistently outperformed the baselines with a larger performance advantage observed at very high accelerations (e.g., 20 times). k-GINR offers great value for direct non-Cartesian k-space reconstruction for new incoming patients across a wide range of accelerations liver anatomy.

eess.IV

Rapid Reconstruction of Extremely Accelerated Liver 4D MRI via Chained Iterative Refinement

Abstract Purpose: High-quality 4D MRI requires an impractically long scanning time for dense k-space signal acquisition covering all respiratory phases. Accelerated sparse sampling followed by reconstruction enhancement is desired but often results in degraded image quality and long reconstruction time. We hereby propose the chained iterative reconstruction network (CIRNet) for efficient sparse-sampling reconstruction while maintaining clinically deployable quality. Methods: CIRNet adopts the denoising diffusion probabilistic framework to condition the image reconstruction through a stochastic iterative denoising process. During training, a forward Markovian diffusion process is designed to gradually add Gaussian noise to the densely sampled ground truth (GT), while CIRNet is optimized to iteratively reverse the Markovian process from the forward outputs. At the inference stage, CIRNet performs the reverse process solely to recover signals from noise, conditioned upon the undersampled input. CIRNet processed the 4D data (3D+t) as temporal slices (2D+t). The proposed framework is evaluated on a data cohort consisting of 48 patients (12332 temporal slices) who underwent free-breathing liver 4D MRI. 3-, 6-, 10-, 20- and 30-times acceleration were examined with a retrospective random undersampling scheme. Compressed sensing (CS) reconstruction with a spatiotemporal constraint and a recently proposed deep network, Re-Con-GAN, are selected as baselines. Results: CIRNet consistently achieved superior performance compared to CS and Re-Con-GAN. The inference time of CIRNet, CS, and Re-Con-GAN are 11s, 120s, and 0.15s. Conclusion: A novel framework, CIRNet, is presented. CIRNet maintains useable image quality for acceleration up to 30 times, significantly reducing the burden of 4DMRI.

eess.IV

TomoGRAF: A Robust and Generalizable Reconstruction Network for Single-View Computed Tomography

Computed tomography (CT) provides high spatial resolution visualization of 3D structures for scientific and clinical applications. Traditional analytical/iterative CT reconstruction algorithms require hundreds of angular data samplings, a condition that may not be met in practice due to physical and mechanical limitations. Sparse view CT reconstruction has been proposed using constrained optimization and machine learning methods with varying success, less so for ultra-sparse view CT reconstruction with one to two views. Neural radiance field (NeRF) is a powerful tool for reconstructing and rendering 3D natural scenes from sparse views, but its direct application to 3D medical image reconstruction has been minimally successful due to the differences between optical and X-ray photon transportation. Here, we develop a novel TomoGRAF framework incorporating the unique X-ray transportation physics to reconstruct high-quality 3D volumes using ultra-sparse projections without prior. TomoGRAF captures the CT imaging geometry, simulates the X-ray casting and tracing process, and penalizes the difference between simulated and ground truth CT sub-volume during training. We evaluated the performance of TomoGRAF on an unseen dataset of distinct imaging characteristics from the training data and demonstrated a vast leap in performance compared with state-of-the-art deep learning and NeRF methods. TomoGRAF provides the first generalizable solution for image-guided radiotherapy and interventional radiology applications, where only one or a few X-ray views are available, but 3D volumetric information is desired.

eess.IV

High-Quality Data Augmentation for Low-Resource NMT: Combining a Translation Memory, a GAN Generator, and Filtering

Back translation, as a technique for extending a dataset, is widely used by researchers in low-resource language translation tasks. It typically translates from the target to the source language to ensure high-quality translation results. This paper proposes a novel way of utilizing a monolingual corpus on the source side to assist Neural Machine Translation (NMT) in low-resource settings. We realize this concept by employing a Generative Adversarial Network (GAN), which augments the training data for the discriminator while mitigating the interference of low-quality synthetic monolingual translations with the generator. Additionally, this paper integrates Translation Memory (TM) with NMT, increasing the amount of data available to the generator. Moreover, we propose a novel procedure to filter the synthetic sentence pairs during the augmentation process, ensuring the high quality of the data.

cs.CL

Paired Conditional Generative Adversarial Network for Highly Accelerated Liver 4D MRI

Purpose: 4D MRI with high spatiotemporal resolution is desired for image-guided liver radiotherapy. Acquiring densely sampling k-space data is time-consuming. Accelerated acquisition with sparse samples is desirable but often causes degraded image quality or long reconstruction time. We propose the Reconstruct Paired Conditional Generative Adversarial Network (Re-Con-GAN) to shorten the 4D MRI reconstruction time while maintaining the reconstruction quality. Methods: Patients who underwent free-breathing liver 4D MRI were included in the study. Fully- and retrospectively under-sampled data at 3, 6 and 10 times (3x, 6x and 10x) were first reconstructed using the nuFFT algorithm. Re-Con-GAN then trained input and output in pairs. Three types of networks, ResNet9, UNet and reconstruction swin transformer, were explored as generators. PatchGAN was selected as the discriminator. Re-Con-GAN processed the data (3D+t) as temporal slices (2D+t). A total of 48 patients with 12332 temporal slices were split into training (37 patients with 10721 slices) and test (11 patients with 1611 slices). Results: Re-Con-GAN consistently achieved comparable/better PSNR, SSIM, and RMSE scores compared to CS/UNet models. The inference time of Re-Con-GAN, UNet and CS are 0.15s, 0.16s, and 120s. The GTV detection task showed that Re-Con-GAN and CS, compared to UNet, better improved the dice score (3x Re-Con-GAN 80.98%; 3x CS 80.74%; 3x UNet 79.88%) of unprocessed under-sampled images (3x 69.61%). Conclusion: A generative network with adversarial training is proposed with promising and efficient reconstruction results demonstrated on an in-house dataset. The rapid and qualitative reconstruction of 4D liver MR has the potential to facilitate online adaptive MR-guided radiotherapy for liver cancer.

eess.IV

Learning Dynamic MRI Reconstruction with Convolutional Network Assisted Reconstruction Swin Transformer

Dynamic magnetic resonance imaging (DMRI) is an effective imaging tool for diagnosis tasks that require motion tracking of a certain anatomy. To speed up DMRI acquisition, k-space measurements are commonly undersampled along spatial or spatial-temporal domains. The difficulty of recovering useful information increases with increasing undersampling ratios. Compress sensing was invented for this purpose and has become the most popular method until deep learning (DL) based DMRI reconstruction methods emerged in the past decade. Nevertheless, existing DL networks are still limited in long-range sequential dependency understanding and computational efficiency and are not fully automated. Considering the success of Transformers positional embedding and "swin window" self-attention mechanism in the vision community, especially natural video understanding, we hereby propose a novel architecture named Reconstruction Swin Transformer (RST) for 4D MRI. RST inherits the backbone design of the Video Swin Transformer with a novel reconstruction head introduced to restore pixel-wise intensity. A convolution network called SADXNet is used for rapid initialization of 2D MR frames before RST learning to effectively reduce the model complexity, GPU hardware demand, and training time. Experimental results in the cardiac 4D MR dataset further substantiate the superiority of RST, achieving the lowest RMSE of 0.0286 +/- 0.0199 and 1 - SSIM of 0.0872 +/- 0.0783 on 9 times accelerated validation sequences.

eess.IV