SearcharxivSearch

arXiv subjects

Hengrong Lan

Publications and source records attributed to Hengrong Lan.

At least 19 recordsLinked to original sources

Photoacoustic Tensile Imaging

Photoacoustic (PA) imaging combines the high optical absorption contrast of optical imaging with the deep tissue penetration of ultrasound detection, offering great potential for functional imaging and disease diagnosis. However, current PA imaging methods mainly explore optical absorption properties of biological tissue. To the best of our knowledge, tensile measurement based on PA effect is still an untapped area to be explored. In this work, we propose photoacoustic tensile imaging (PATI), a new PA imaging modality enabling quantitative assessment of tensile stress in biological samples. PATI exploits the nonlinear PA response induced by dual-pulse laser excitation to establish a mapping between the applied tension and the increment of the nonlinear PA signal. By varying the temporal delay between the heating and detecting laser pulses, the relationship between tensile force and nonlinear PA characteristics is quantitatively analyzed. Phantom experiments demonstrate a strong correlation between the nonlinear PA signal intensity and the applied tensile force. These results confirm the feasibility of the proposed approach for tensile force monitoring, which holds potential in biomedical applications, such as vascular pressure monitoring.

physics.optics

Transcranial Photoacoustic Imaging for Human Intracranial Pressure Evaluation

Photoacoustic imaging (PAI), by combining high optical contrast with ultrasonic resolution, offers a promising noninvasive approach for dynamic monitoring of cerebral vasculature. However, transcranial PAI still faces significant challenges due to strong attenuation of both optical and acoustic signals by the skull. In this study, we propose a multi-wavelength photoacoustic tomography system and method for intracranial pressure (ICP) assessment, enabling visualization of cross-sectional structures of the middle cerebral artery (MCA) through the human temporal bone. By utilizing multi-wavelength excitation in the near-infrared-I (NIR-I) window, quantitative maps of blood oxygen saturation ($\mathbf{sO_2}$) are reconstructed, and the relationship between oxygenation dynamics and ICP variations is established. Experimental results demonstrate that the proposed system can successfully capture dynamic $\mathbf{sO_2}$ fluctuations in the MCA despite skull attenuation, revealing its characteristic responses to ICP changes. This work provides a high-precision, noninvasive imaging tool for early stroke diagnosis, cerebral vascular function assessment, and neurointerventional guidance, highlighting the clinical translational potential of PAI in neuroscience.

physics.med-ph

Fast Sampling generative model for Ultrasound image reconstruction

Image reconstruction from radio-frequency data is pivotal in ultrafast plane wave ultrasound imaging. Unlike the conventional delay-and-sum (DAS) technique, which relies on somewhat imprecise assumptions, deep learning-based methods perform image reconstruction by training on paired data, leading to a notable enhancement in image quality. Nevertheless, these strategies often exhibit limited generalization capabilities. Recently, denoising diffusion models have become the preferred paradigm for image reconstruction tasks. However, their reliance on an iterative sampling procedure results in prolonged generation time. In this paper, we propose a novel sampling framework that concurrently enforces data consistency of ultrasound signals and data-driven priors. By leveraging the advanced diffusion model, the generation of high-quality images is substantially expedited. Experimental evaluations on an in-vivo dataset indicate that our approach with a single plane wave surpasses DAS with spatial coherent compounding of 75 plane waves.

cs.CV

Single PW takes a shortcut to compound PW in US imaging

Reconstruction of ultrasound (US) images from radio-frequency data can be conceptualized as a linear inverse problem. Traditional deep learning approaches, which aim to improve the quality of US images by directly learning priors, often encounter challenges in generalization. Recently, diffusion-based generative models have received significant attention within the research community due to their robust performance in image reconstruction tasks. However, a limitation of these models is their inherent low speed in generating image samples from pure Gaussian noise progressively. In this study, we exploit the inherent similarity between the US images reconstructed from a single plane wave (PW) and PW compounding PWC). We hypothesize that a single PW can take a shortcut to reach the diffusion trajectory of PWC, removing the need to begin with Gaussian noise. By employing an advanced diffusion model, we demonstrate its effectiveness in US image reconstruction, achieving a substantial reduction in sampling steps. In-vivo experimental results indicate that our approach can reduce sampling steps by 60%, while preserving comparable performance metrics with the conventional diffusion model.

cs.CV

Cross-domain Self-supervised Framework for Photoacoustic Computed Tomography Image Reconstruction

Accurate image reconstruction is crucial for photoacoustic (PA) computed tomography (PACT). Recently, deep learning has been used to reconstruct the PA image with a supervised scheme, which requires high-quality images as ground truth labels. In practice, there are inevitable trade-offs between cost and performance since the use of more channels is an expensive strategy to access more measurements. Here, we propose a cross-domain unsupervised reconstruction (CDUR) strategy with a pure transformer model, which overcomes the lack of ground truth labels from limited PA measurements. The proposed approach exploits the equivariance of PACT to achieve high performance with a smaller number of channels. We implement a self-supervised reconstruction in a model-based form. Meanwhile, we also leverage the self-supervision to enforce the measurement and image consistency on three partitions of measured PA data, by randomly masking different channels. We find that dynamically masking a high proportion of the channels, e.g., 80%, yields nontrivial self-supervisors in both image and signal domains, which decrease the multiplicity of the pseudo solution to efficiently reconstruct the image from fewer PA measurements with minimum error of the image. Experimental results on in-vivo PACT dataset of mice demonstrate the potential of our unsupervised framework. In addition, our method shows a high performance (0.83 structural similarity index (SSIM) in the extreme sparse case with 13 channels), which is close to that of supervised scheme (0.77 SSIM with 16 channels). On top of all the advantages, our method may be deployed on different trainable models in an end-to-end manner.

eess.IV

Score-based Generative Models for Photoacoustic Image Reconstruction with Rotation Consistency Constraints

Photoacoustic tomography (PAT) is a newly emerged imaging modality which enables both high optical contrast and acoustic depth of penetration. Reconstructing images of photoacoustic tomography from limited amount of senser data is among one of the major challenges in photoacoustic imaging. Previous works based on deep learning were trained in supervised fashion, which directly map the input partially known sensor data to the ground truth reconstructed from full field of view. Recently, score-based generative models played an increasingly significant role in generative modeling. Leveraging this probabilistic model, we proposed Rotation Consistency Constrained Score-based Generative Model (RCC-SGM), which recovers the PAT images by iterative sampling between Langevin dynamics and a constraint term utilizing the rotation consistency between the images and the measurements. Our proposed method can generalize to different measurement processes (32.29 PSNR with 16 measurements under random sampling, whereas 28.50 for supervised counterpart), while supervised methods need to train on specific inverse mappings.

cs.CV

Size-adjustable Ring-shape Photoacoustic Tomography System

Photoacoustic tomography (PAT) combines the advantages of the spectroscopic optical absorption contrast and acoustic resolution with deep penetration, and becomes an important novel biomedical imaging technology for scientific research and clinical diagnosis. In this paper, an imaging size-adjustable PAT system is proposed for clinical applications, which can adapt for different size imaging targets. Comparing with the conventional PAT system setup which with a fixed radius ring shape ultrasound transducer (UT) array, the proposed system, which is based on sectorial ultrasound transducer array (SUTA), is more flexible for different size targets imaging. There are 32 elements for each SUTA, and four SUTAs form a 128-channel UT array for photoacoustic wave detection. The four SUTAs are controlled by four stepper motors, and change the SUTAs distribute positon that adapt for imaging applications. The radius of the proposed system imaging region of interest (ROI) can be adjusted from 50 mm to 90 mm, which is much more flexible than the conventional full ring UT array PAT system. The simulation results generated by the MATLAB k-wave toolbox very well demonstrate the feasibility of the proposed system. To further validate the proposed system for size-adjustable imaging, a vascular mimicking phantom and ex-vivo pork breast with indocyanine green (ICG) injected are imaged to prove its feasibility for clinical applications.

physics.ins-det

Deep Learning Adapted Acceleration for Limited-view Photoacoustic Computed Tomography

Photoacoustic imaging (PAI) is a non-invasive imaging modality that detects the ultrasound signal generated from tissue with light excitation. Photoacoustic computed tomography (PACT) uses unfocused large-area light to illuminate the target with ultrasound transducer array for PA signal detection. Limited-view issue could cause a low-quality image in PACT due to the limitation of geometric condition. The model-based method is used to resolve this problem, which contains different regularization. To adapt fast and high-quality reconstruction of limited-view PA data, in this paper, a model-based method that combines the mathematical variational model with deep learning is proposed to speed up and regularize the unrolled procedure of reconstruction. A deep neural network is designed to adapt the step of the gradient updated term of data consistency in the gradient descent procedure, which can obtain a high-quality PA image only with a few iterations. Note that all parameters and priors are automatically learned during the offline training stage. In experiments, we show that this method outperforms the other methods with half-view (180 degrees) simulation and real data. The comparison of different model-based methods show that our proposed scheme has superior performances (over 0.05 for SSIM) with same iteration (3 times) steps. Furthermore, an unseen data is used to validate the generalization of different methods. Finally, we find that our method obtains superior results (0.94 value of SSIM for in vivo) with a high robustness and accelerated reconstruction.

eess.IV

AS-Net: Fast Photoacoustic Reconstruction with Multi-feature Fusion from Sparse Data

Photoacoustic (PA) imaging is a biomedical imaging modality capable of acquiring high-contrast images of optical absorption at depths much greater than traditional optical imaging techniques. However, practical instrumentation and geometry limit the number of available acoustic sensors surrounding the imaging target, which results in the sparsity of sensor data. Conventional PA image reconstruction methods give severe artifacts when they are applied directly to the sparse PA data. In this paper, we firstly propose to employ a novel signal processing method to make sparse PA raw data more suitable for the neural network, concurrently speeding up image reconstruction. Then we propose Attention Steered Network (AS-Net) for PA reconstruction with multi-feature fusion. AS-Net is validated on different datasets, including simulated photoacoustic data from fundus vasculature phantoms and experimental data from in vivo fish and mice. Notably, the method is also able to eliminate some artifacts present in the ground truth for in vivo data. Results demonstrated that our method provides superior reconstructions at a faster speed.

cs.CV

Compressed Sensing for Photoacoustic Computed Tomography Using an Untrained Neural Network

Photoacoustic (PA) computed tomography (PACT) shows great potentials in various preclinical and clinical applications. A great number of measurements are the premise that obtains a high-quality image, which implies a low imaging rate or a high system cost. The artifacts or sidelobes could pollute the image if we decrease the number of measured channels or limit the detected view. In this paper, a novel compressed sensing method for PACT using an untrained neural network is proposed, which decreases half number of the measured channels and recoveries enough details. This method uses a neural network to reconstruct without the requirement for any additional learning based on the deep image prior. The model can reconstruct the image only using a few detections with gradient descent. Our method can cooperate with other existing regularization, and further improve the quality. In addition, we introduce a shape prior to easily converge the model to the image. We verify the feasibility of untrained network based compressed sensing in PA image reconstruction, and compare this method with a conventional method using total variation minimization. The experimental results show that our proposed method outperforms 32.72% (SSIM) with the traditional compressed sensing method in the same regularization. It could dramatically reduce the requirement for the number of transducers, by sparsely sampling the raw PA data, and improve the quality of PA image significantly.

cs.CV

Photoacoustic-monitored laser treatment for tattoo removal: a feasibility study

Skin blemishes and diseases have attracted increasing research interest in recent decades, due to their growing frequency of occurrence and the severity of related diseases. Various laser treatment approaches have been introduced for the alleviation and removal of skin pigmentation. The treatments' effects highly depend on the experience and prognosis of the relevant operators. But, the operation process lacks real-time feedback, which may directly reflect the extent of the treatment. In this manuscript, we report a photoacoustic-guided laser treatment method with a feasibility study, specifically for laser treatment targeting the tattoo's removal. The results well validated the feasibility of the proposed method through the experiments on phantoms and ex vivo pig skin samples.

eess.SP

A Jointed Feature Fusion Framework for Photoacoustic Reconstruction

Photoacoustic (PA) computed tomography (PACT) reconstructs the initial pressure distribution from raw PA signals. The standard reconstruction of medical image could cause the artifacts due to interferences or ill-posed setup. Recently, deep learning has been used to reconstruct the PA image with ill-posed conditions. Most works remove the artifacts from image domain, and compensate the limited-view from dataset. In this paper, we propose a jointed feature fusion framework (JEFF-Net) based on deep learning to reconstruct the PA image using limited-view data. The cross-domain features from limited-view position-wise data and the reconstructed image are fused by a backtracked supervision. Specifically, our results could generate superior performance, whose artifacts are drastically reduced in the output compared to ground-truth (full-view reconstructed result). In this paper, a quarter position-wise data (32 channels) is fed into model, which outputs another 3-quarters-view data (96 channels). Moreover, two novel losses are designed to restrain the artifacts by sufficiently manipulating superposed data. The numerical and in-vivo results have demonstrated the superior performance of our method to reconstruct the full-view image without artifacts. Finally, quantitative evaluations show that our proposed method outperformed the ground-truth in some metrics.

cs.CV

Deep Learning Enabled Real-Time Photoacoustic Tomography System via Single Data Acquisition Channel

Photoacoustic computed tomography (PACT) combines the optical contrast of optical imaging and the penetrability of sonography. In this work, we develop a novel PACT system to provide real-time imaging, which is achieved by a 120-elements ultrasound array only using a single data acquisition (DAQ) channel. To reduce the channel number of DAQ, we superimpose 30 nearby channels' signals together in the analog domain, and shrinking to 4 channels of data (120/30=4). Furthermore, a four-to-one delay-line module is designed to combine these four channels' data into one channel before entering the single-channel DAQ, followed by decoupling the signals after data acquisition. To reconstruct the image from four superimposed 30-channels'PA signals, we train a dedicated deep learning model to reconstruct the final PA image. In this paper, we present the preliminary results of phantom and in-vivo experiments, which manifests its robust real-time imaging performance. The significance of this novel PACT system is that it dramatically reduces the cost of multi-channel DAQ module (from 120 channels to 1 channel), paving the way to a portable, low-cost and real-time PACT system.

eess.IV

Low-Cost Optoacoustic Tomography System with Programmable Acoustic Delay-Line

Photoacoustic tomography (PAT) is an emerging technology for biomedical imaging that combines the superiorities of high optical contrast and acoustic penetration. In the PAT system, more photoacoustic (PA) signals are preferred to be detected from full field of view to reconstruct PA images with higher fidelity. However, the requirement for more PA signals detection leads to more time consumption for single-channel scanning based PAT system, or higher cost of data acquisition (DAQ) module for an array-based PAT system. To address this issue, we proposed a programmable acoustic delay line module to reduce DAQ cost and accelerate imaging speed for PAT system. The module is based on bidirectional conversion between acoustic signals and electrical signals, including ultrasound transmission in between to provide sufficient time delay. The acoustic delay line module achieves tens or hundreds of microseconds delay for each channel, and is controlled by a programmable control unit. In this work, it achieves to merge four inputs of PA signals into one output signal, which can be recovered into original four PA signals in the digital domain after DAQ. The imaging experiments of pencil leads embedded in agar phantom is conducted by the PAT system equipped with the proposed programmable acoustic delay-line module, which demonstrated its feasibility in biomedical imaging system.

physics.ins-det

Deep learning for photoacoustic imaging: a survey

Machine learning has been developed dramatically and witnessed a lot of applications in various fields over the past few years. This boom originated in 2009, when a new model emerged, that is, the deep artificial neural network, which began to surpass other established mature models on some important benchmarks. Later, it was widely used in academia and industry. Ranging from image analysis to natural language processing, it fully exerted its magic and now become the state-of-the-art machine learning models. Deep neural networks have great potential in medical imaging technology, medical data analysis, medical diagnosis and other healthcare issues, and is promoted in both pre-clinical and even clinical stages. In this review, we performed an overview of some new developments and challenges in the application of machine learning to medical image analysis, with a special focus on deep learning in photoacoustic imaging. The aim of this review is threefold: (i) introducing deep learning with some important basics, (ii) reviewing recent works that apply deep learning in the entire ecological chain of photoacoustic imaging, from image reconstruction to disease diagnosis, (iii) providing some open source materials and other resources for researchers interested in applying deep learning to photoacoustic imaging.

cs.CV

Limited-view Photoacoustic Imaging Reconstruction With Dual Domain Inputs Under Mutual Information Constraint

Based on photoacoustic effect, photoacoustic tomography is developing very fast in recent years, and becoming an important imaging tool for both preclinical and clinical studies. With enough ultrasound transducers placed around the biological tissue, PAT can provide both deep penetration and high image contrast by hybrid usage of light and sound. However, considering space and measurement environmental limitations, transducers are always placed in a limited-angle way, which means that the other side without transducer coverage suffers severe information loss. With conventional image reconstruction algorithms, the limited-view tissue induces artifacts and information loss, which may cause doctors misdiagnosis or missed diagnosis. In order to solve limited-view PA imaging reconstruction problem, we propose to use both time domain and frequency domain reconstruction algorithms to get delay-and-sum (DAS) image inputs and k-space image inputs. These dual domain images share nearly same texture information but different artifact information, which can teach network how to distinguish these two kinds of information at input level. In this paper, we propose Dual Domain Unet (DuDoUnet) with specially designed Information Sharing Block (ISB), which can further share two domains' information and distinguish artifacts. Besides, we use mutual information (MI) with an auxiliary network, whose inputs and outputs are both ground truth, to compensate prior knowledge of limited-view PA inputs. The proposed method is verified with a public clinical database, and shows superior results with SSIM = 93.5622% and PSNR = 20.8859.

eess.IV

Light-scanning hand-held photoacoustic probe design

Significance: We proposed a new design of hand-held linear-array photoacoustic (PA) probe which can acquire multi images via motor moving. Moreover, images from different locations are utilized via imaging fusion for SNR enhancement. Aim: We devised an adjustable hand-held for the purpose of realizing different images at diverse location for further image fusion. For realizing the light spot which is more matched with the Ultrasonic transducer detection area, we specially design a light adjust unit. Moreover, due to no displacement among the images, there is no need to execute image register process. The program execution time be reduced, greatly. Approach: mechanical design; Montel carol simulation; no-registration image fusion; Spot compression. Results: Multiple PA images with different optical illumination areas were acquired. After image fusion, we obtained fused PA images with higher signal-to-noise-ratio (SNR) and image fidelity than each single PA image. A quantitative comparison shows that the SNR of fused image is improved by 36.06% in agar-milk phantom, and 44.69% in chicken breast phantom, respectively. Conclusions: In this paper, the light scanning adjustable hand-held PA imaging probe is proposed, which can realize PA imaging with different illumination positions via adjusting the optical unit.

physics.med-ph

Deep Learning Enables Robust and Precise Light Focusing on Treatment Needs

If light passes through the body tissues, focusing only on areas where treatment needs, such as tumors, will revolutionize many biomedical imaging and therapy technologies. So how to focus light through deep inhomogeneous tissues overcoming scattering is Holy Grail in biomedical areas. In this paper, we use deep learning to learn and accelerate the process of phase pre-compensation using wavefront shaping. We present an approach (LoftGAN, light only focuses on treatment needs) for learning the relationship between phase domain X and speckle domain Y . Our goal is not just to learn an inverse mapping F:Y->X such that we can know the corresponding X needed for imaging Y like most work, but also to make focusing that is susceptible to disturbances more robust and precise by ensuring that the phase obtained can be forward mapped back to speckle. So we introduce different constraints to enforce F(Y)=X and H(F(Y))=Y with the transmission mapping H:X->Y. Both simulation and physical experiments are performed to investigate the effects of light focusing to demonstrate the effectiveness of our method and comparative experiments prove the crucial improvement of robustness and precision. Codes are available at https://github.com/ChangchunYang/LoftGAN.

eess.IV