SearcharxivSearch

arXiv subjects

Henry C. Burridge

Publications and source records attributed to Henry C. Burridge.

5 recordsLinked to original sources

The CHEPA model: assessing the impact of HEPA filter units in classrooms using a fast-running coupled indoor air quality and dynamic thermal model

The quality of the classroom environment, including ventilation, air quality and thermal conditions, has an important impact on children's health and academic achievements. The use of portable HEPA filter air cleaners is widely suggested as a strategy to mitigate exposure to particulate matter and airborne viruses. However, there is a need to quantify the relative benefits of such devices including the impacts on energy use. We present a simple coupled dynamic thermal and air quality model and apply it to naturally ventilated classrooms, representative of modern and Victorian era construction. We consider the addition of HEPA filters with, and without, reduced opening of windows, and explore concentrations of carbon dioxide (\co), \PM, airborne viral RNA, classroom temperature and energy use. Results indicate the addition of HEPA filters was predicted to reduce \PM~ by 40--60\% and viral RNA by 30--50\% depending on the classroom design and window opening behaviour. The energy cost of running HEPA filters is likely to be only 1\%--2\% of the classroom heating costs. In scenarios when HEPA filters were on and window opening was reduced (to account for the additional clean air delivery rate of the filters), the heating cost was predicted to be reduced by as much as -13\%, and these maximum reductions grew to -46\% in wintertime simulations. In these scenarios the HEPA filters result in a notable reduction in \PM~and viral RNA, but the \co\ concentration is significantly higher. The model provides a mechanism for exploring the relative impact of ventilation and air cleaning strategies on both exposures and energy costs, enabling an understanding of where trade-offs lie.

physics.soc-ph

Robustness of point measurements of carbon dioxide concentration for the inference of ventilation rates in a wintertime classroom

Indoor air quality in schools and classrooms is paramount for the health and well-being of pupils and staff. CO2 monitors offer a cost-effective way to assess and manage ventilation provision. However, often only a single point measurement is available which might not be representative of the CO2 distribution within the room. A relatively generic UK classroom in wintertime is simulated using CFD. The natural ventilation provision is driven by buoyancy through high- and low-level openings in both an opposite-ended or single-ended configuration, in which only the horizontal location of the high-level vent is modified. CO2 is modelled as a passive scalar and is shown not to be `well-mixed' within the space. Perhaps surprisingly, the single-ended configuration leads to a `more efficient' ventilation, with lower average CO2 concentration. Measurements taken near the walls, often the location of CO2 monitors, are compared with those made throughout the classroom and found to be more representative of the ventilation rate if made above the breathing zone. These findings are robust with respect to ventilation flow rates and to the flow patterns observed, which were tested by varying the effective vent areas and the ratio of the vent areas.

physics.flu-dyn

Uniformly distributed floor sources of buoyancy can give rise to significant spatial inhomogeneities within rooms

Displacement ventilation, where cool external air enters a room through low-level vents and warmer air leaves through high-level vents, is characterised by vertical gradients in pressure arising from the warmer indoor temperatures. Models usually assume that horizontal variations of temperature difference are small in comparison and are, therefore, unimportant. Small-scale laboratory experiments and computational fluid dynamics were used to examine these flows, driven by a uniformly heated floor. These experiments and simulations show that the horizontal variations of temperature difference can be neglected for predictions of the bulk ventilation rate; however, they also evidence that these horizontal variations can be significant and play a critical role in establishing the pattern of flow within the room -- this renders the horizontal position of the low- and high-level vents (relative to one another) important. We consider two cases: single-ended (where inlet and outlet are at the same end of the room) and opposite-ended. In both cases the ventilation flow rate is the same. However, in the opposite-ended case a dead zone is established in the upper part of the room which results in significant horizontal variations. We consider the formation of this dead zone by examining the streamline patterns and the age of air within the room. We discuss the implications for occupant exposure to pollutants and airborne disease.

physics.flu-dyn

The internal structure of forced fountains

We study the mixing processes inside a forced fountain using data from direct numerical simulation. The outer boundary of the fountain with the ambient is a turbulent/non-turbulent interface. Inside the fountain, two internal boundaries, both turbulent/turbulent interfaces, are identified: 1) the classical boundary between upflow and downflow which is composed of the loci of points of zero mean vertical velocity; and 2) the streamline that separates the mean flow emitted by the source from the entrained fluid from the ambient (the separatrix). We show that entrainment due to turbulent fluxes across the internal boundary is at least as important as that by the mean flow. However, entrainment by the turbulence behaves substantively differently from that by the mean flow and cannot be modelled using the same assumptions. This presents a challenge for existing models of turbulent fountains and other environmental flows that evolve inside turbulent environments.

physics.flu-dyn

Predictive and retrospective modelling of airborne infection risk using monitored carbon dioxide

The risk of long range, herein `airborne', infection needs to be better understood and is especially urgent during the current COVID-19 pandemic. We present a method to determine the relative risk of airborne transmission that can be readily deployed with either modelled or monitored CO$_2$ data and occupancy levels within an indoor space. For spaces regularly, or consistently, occupied by the same group of people, e.g. an open-plan office or a school classroom, we establish protocols to assess the absolute risk of airborne infection of this regular attendance at work or school. We present a methodology to easily calculate the expected number of secondary infections arising from a regular attendee becoming infectious and remaining pre/asymptomatic within these spaces. We demonstrate our model by calculating risks for both a modelled open-plan office and by using monitored data recorded within a small naturally ventilated office. In addition, by inferring ventilation rates from monitored CO$_2$ we show that estimates of airborne infection can be accurately reconstructed; thereby offering scope for more informed retrospective modelling should outbreaks occur in spaces where CO$_2$ is monitored. Our modelling suggests that regular attendance at an office for work is unlikely to significantly contribute to the pandemic but only if relatively quiet desk-based work is carried out in the presence of adequate ventilation (i.e. at least 10\,l/s/p following UK guidance), appropriate hygiene controls, distancing measures, and that all commuting presents minimal infection risk. Crucially, modelling even moderate changes to the conditions within the office, or basing estimates for the infectivity of the SARS-CoV-2 variant B1.1.7 current data, typically results in the prediction that for a single infector within the office the airborne route alone gives rises to more than one secondary infection.

physics.soc-ph