Searcharxiv⌕ Search

arXiv subjects

Herman L. Marshall

Publications and source records attributed to Herman L. Marshall.

134 records · Page 8Linked to original sources

The Remarkably Featureless High Resolution X-ray Spectrum of Mrk 478

An observation of Mrk 478 using the Chandra Low Energy Transmission Grating Spectrometer is presented. The source exhibited 30-40% flux variations on timescales of order 10000 s together with a slow decline in the spectral softness over the full 80 ks observation. The 0.15--3.0 keV spectrum is well fitted by a single power law with photon index of Gamma = 2.91 +/- 0.03. Combined with high energy data from BeppoSAX, the spectrum from 0.15 to 10 keV is well fit as the sum of two power laws with Gamma = 3.03 +/- 0.04, which dominates below 2 keV and 1.4 +/- 0.2, which dominates above 2 keV (quoting 90% confidence uncertainties). No significant emission or absorption features are detected in the high resolution spectrum, supporting our previous findings using the Extreme Ultraviolet Explorer but contradicting the claims of emission lines by Hwang & Bowyer (1997). There is no evidence of a warm absorber, as found in the high resolution spectra of many Sy 1 galaxies including others classified as narrow line Sy 1 galaxies such as Mrk 478. We suggest that the X-ray continuum may result from Comptonization of disk thermal emission in a hot corona through a range of optical depths.

astro-ph↗

The Flight Spectral Response of the ACIS Instrument

We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving over the course of the mission. The spectral resolution of the frontside-illuminated (FI) CCDs changed dramatically in the first month of the mission due to radiation damage. Since that time, the spectral resolution of the FI CCDs and the backside-illuminated (BI) CCDs have evolved gradually with time. We demonstrate the efficacy of charge-transfer inefficiency (CTI) correction algorithms which recover some of the lost performance. The detection efficiency of the ACIS instrument has been declining throughout the mission, presumably due to a layer of contamination building up on the filter and/or CCDs. We present a characterization of the energy dependence of the excess absorption and demonstrate software which models the time dependence of the absorption from energies of 0.4 keV and up. The spectral redistribution function and the detection efficiency are well-characterized at energies from 1.5 to 8.0 keV. The calibration at energies below 1.5 keV is challenging because of the lack of strong lines in the calibration source and also because of the inherent non-linear dependence with energy of the CTI and the absorption by the contamination layer. We have been using data from celestial sources with relatively simple spectra to determine the quality of the calibration below 1.5 keV. The analysis of these observations demonstrate that the CTI correction recovers a significant fraction of the spectral resolution of the FI CCDs and the models of the time-dependent absorption result in consistent measurements of the flux at low energies for data from a BI (S3) CCD.

astro-ph↗

Chandra High-Resolution Spectrum of the Anomalous X-ray Pulsar 4U 0142+61

We report on a 25 ks observation of the 8.7 s anomalous X-ray pulsar 4U~0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody with photon index Gamma=3.3+/-0.4 and kT=0.418+/-0.013 keV. No evidence was found for emission or absorption lines, with an upper limit of ~50 eV on the equivalent width of broad features in the 2.5-13 A (0.95-5.0 keV) range and an upper limit of ~10 eV on the equivalent width of narrow features in the 4.1-17.7 A (0.7-3.0 keV) range. If the source is a magnetar, then the absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. We find no strong features that are indicative of cyclotron absorption for magnetic field strengths of (1.9-9.8)x10^{14} G. This is still consistent with the dipole field strength of B=1.3x10^{14} G (at the polar cap) estimated from the pulsar's spindown.

astro-ph↗

Chandra/HETGS Spectroscopy of the Anomalous X-ray Pulsar 4U 0142+61

We report on a 25 ks observation of the anomalous X-ray pulsar 4U 0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody model with photon index Gamma=3.3+/-0.4 and blackbody temperature kT=0.418+/-0.013 keV. The pulsar frequency was 0.1150966+/-0.0000017 Hz and the pulse fractions were between 8.7% and 21%, which are also consistent with past measurements. No evidence was found for emission or absorption lines with an upper limit of ~50 eV on the equivalent width of a broad feature in the 2.5-13 A (0.95-4.96 keV) range. The absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. For the energy range given above, the allowed magnetic field strengths of 4U 0142+61 are B<1.9x 10^14 G and B>9.8x 10^14 G.

astro-ph↗

Double-Peaked X-Ray Lines from the Oxygen/Neon-Rich Accretion Disk in 4U1626-67

We report on a 39 ks observation of the 7.7-s low-mass X-ray binary pulsar 4U1626-67 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-Ray Observatory. This ultracompact system consists of a disk-accreting magnetic neutron star and a very low mass, hydrogen-depleted companion in a 42-min binary. We have resolved the previously reported Ne/O emission line complex near 1 keV into Doppler pairs of broadened (2500 km/s FWHM) lines from highly ionized Ne and O. In most cases, the blue and red line components are of comparable strength, with blueshifts of 1550-2610 km/s and redshifts of 770-1900 km/s. The lines appear to originate in hot (10^6 K), dense material just below the X-ray-heated skin of the outer Keplerian accretion disk, or else possibly in a disk wind driven from the pulsar's magnetopause. The observed photoelectric absorption edges of Ne and O appear nearly an order of magnitude stronger than expected from interstellar material and are likely formed in cool, metal-rich material local to the source. Based on the inferred local abundance ratios, we argue that the mass donor in this binary is probably the 0.02 M_sun chemically fractionated core of a C-O-Ne or O-Ne-Mg white dwarf which has previously crystallized.

astro-ph↗

The High Resolution X-ray Spectrum of SS 433 using the Chandra HETGS

We present observations of SS 433 using the Chandra High Energy Transmission Grating Spectrometer. Many emission lines of highly ionized elements are detected with the relativistic blue and red Doppler shifts. The lines are measurably broadened to 1700 km/s (FWHM) and the widths do not depend significantly on the characteristic emission temperature, suggesting that the emission occurs in a freely expanding region of constant collimation with opening angle of 1.23 +/- 0.06 deg. The blue shifts of lines from low temperature gas are the same as those of high temperature gas within our uncertainties, again indicating that the hottest gas we observe to emit emission lines is already at terminal velocity. Fits to the emission line fluxes give a range of temperatures in the jet from 5e6 to 1e8 K. We derive the emission measure as a function of temperature for a four component model that fits the line flux data. Using the density sensitive Si XIII triplet, the characteristic electron density is 1e14 cm^{-3}, where the gas temperature is about 1.3e7 K. Based on an adiabatic expansion model of the jet, the electron densities drop from ~2e15 to 4e13 cm^{-3} at distances of 2e10 to 2e11 cm from the apex of the jet cone. The jet mass outflow rate is 1.5e-7 Msun / yr. The kinetic power is 3.2e38 erg/s, which is x1000 larger than the unabsorbed 2-10 keV X-ray luminosity. The bremsstrahlung emission associated with the lines can account for the entire continuum; we see no direct evidence for an accretion disk. The image from zeroth order shows extended emission at a scale of ~2", aligned in the general direction of the radio jets.

astro-ph↗

Revealing the Energetics and Structure of AGN Jets

Until very recently, few constraints existed on the physics of jets, even though they represent the first known evidence of mass outflow in AGN. This has begun to change with HST and Chandra observations, which allow us to observe short-lived, dynamic features, and compare their spectra and morphology to those of longer-lived particles seen in the radio. We examine HST and Chandra observations of M87 and 3C273 which reveal that these two prototype objects seem radically different.

astro-ph↗

Discovery of Spatial and Spectral Structure in the X-Ray Emission from the Crab Nebula

The Chandra X-ray Observatory observed the Crab Nebula and Pulsar during orbital calibration. Zeroth-order images with the High-Energy Transmission Grating (HETG) read-out by the Advanced CCD Imaging Spectrometer spectroscopy array (ACIS-S) show a striking richness of x-ray structure, at a resolution comparable to that of the best ground-based visible-light observations. The HETG--ACIS-S images reveal, for the first time, an x-ray inner ring within the x-ray torus, the suggestion of a hollow-tube structure for the torus, and x-ray knots along the inner ring and (perhaps) along the inward extension of the x-ray jet. Although complicated by instrumental effects and the brightness of the Crab Nebula, the spectrometric analysis shows systematic variations of the x-ray spectrum throughout the Nebula.

astro-ph↗