SearcharxivSearch

arXiv subjects

Hidekazu Hachisu

Publications and source records attributed to Hidekazu Hachisu.

9 recordsLinked to original sources

Frequency ratio of an $^{115}$In$^+$ ion clock and a $^{87}$Sr optical lattice clock

We report on the first frequency ratio measurement of an $^{115}$In+ single ion clock and a $^{87}$Sr optical lattice clock. A hydrogen maser serves as a reference oscillator to measure the ratio by independent optical combs. Over more than 90 000 seconds of measurement time, the frequency ratio $f_{\rm{In^+}}/f_{\rm{Sr}}$ is determined to be 2.952 748 749 874 863 4(21) with relative uncertainty of $7.0 \times 10^{-16}$. The measurement creates a new connection in the network of frequency ratios of optical clocks.

physics.atom-ph

Absolute frequency of $^{87}\mathrm{Sr}$ at $1.8 \times 10^{-16}$ uncertainty by reference to remote Primary Frequency Standards

The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the $^{87}\mathrm{Sr}$ clock transition to be f(Sr)=$429\,228\,004\,229\,873.082(76)$, with a fractional uncertainty of less than 1.8x10$^{-16}$ approaching the systematic limits of the best realization of SI second. Our result is consistent with other recent measurements and further supported by the loop closure over the absolute frequencies of $^{87}\mathrm{Sr}$, $^{171}\mathrm{Yb}$ and direct optical measurements of their ratio.

physics.atom-ph

Months-long real-time generation of a time scale based on an optical clock

Time scales consistently provide precise time stamps and time intervals by combining atomic frequency standards with a reliable local oscillator. Optical frequency standards, however, have not been applied to the generation of time scales, although they provide superb accuracy and stability these days. Here, by steering an oscillator frequency based on the intermittent operation of a $^{87}$Sr optical lattice clock, we realized an "optically steered" time scale TA(Sr) that was continuously generated for half a year. The resultant time scale was as stable as International Atomic Time (TAI) with its accuracy at the $10^{-16}$ level. We also compared the time scale with TT(BIPM16). TT(BIPM) is computed in deferred time each January based on a weighted average of the evaluations of the frequency of TAI using primary and secondary frequency standards. The variation of the time difference TA(Sr) $-$ TT(BIPM16) was 0.79 ns after 5 months, suggesting the compatibility of using optical clocks for time scale generation. The steady signal also demonstrated the capability to evaluate one-month mean scale intervals of TAI over all six months with comparable uncertainties to those of primary frequency standards (PFSs).

physics.atom-ph

SI-traceable measurement of an optical frequency at low $10^{-16}$ level without a local primary standard

SI-traceable measurements of optical frequencies using International Atomic Time (TAI) do not require a local primary frequency reference, but suffer from an uncertainty in tracing to the SI second. For the measurement of the $^{87}$Sr lattice clock transition, we have reduced this uncertainty to low $10^{-16}$ level by averaging three sets of ten-day intermittent measurements, in which we operated the lattice clock for $10^4$ s on each day. Moreover, a combined oscillator of two hydrogen masers was employed as a local flywheel oscillator (LFO) in order to mitigate the impact of sporadic excursion of LFO frequency. The resultant absolute frequency with fractional uncertainty of $4.3\times10^{-16}$ agrees with other measurements based on local state-of-the-art cesium fountains.

physics.atom-ph

Absolute frequency measurement with uncertainty below $1\times 10^{-15}$ using International Atomic Time

The absolute frequency of the $^{87}{\rm Sr}$ clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was calibrated for an evaluation interval of five days instead of the conventional interval of one month which is regularly employed in Circular T. The calibration on a five-day basis removed the uncertainty in assimilating the TAI scale of the five-day mean to that of the one-month mean. The reevaluation resulted in the total uncertainty of $10^{-16}$ level for the first time without local cesium fountains. Since there are presumably no correlations among systematic shifts of cesium fountains worldwide, the measurement is not limited by the systematic uncertainty of a specific primary frequency standard.

physics.atom-ph

Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link

The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser used as a transfer oscillator was reduced by homogeneously distributed intermittent measurement over a five-day grid of TAI. Three sets of four or five days measurements as well as systematic uncertainty of the clock at $8.6\times 10^{-17}$ have resulted in an absolute frequency of $^{87}{\rm Sr}\ {}^1S_0 - {}^3P_0$ clock transition to be 429 228 004 229 872.85 (47) Hz.

physics.atom-ph

Direct comparison of a Ca+ single ion clock against a Sr optical lattice clock

Optical frequency comparison of the 40Ca+ clock transition ν_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition ν_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio ν_{Ca} / ν_{Sr} = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν_{Ca} / ν_{Sr} to reach 1x10-15 in only 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν_{Ca} using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We report the absolute frequency of ^{40}Ca+ with a systematic uncertainty 14 times smaller than our previous measurement [1].

physics.atom-ph

Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty

Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated by the differential gravitational redshift, the residual fractional difference is found to be $(1.0\pm7.3)\times10^{-16}$, confirming the coincidence between the two clocks. The accurate and speedy comparison of distant optical clocks paves the way for a future optical redefinition of the second.

physics.atom-ph

All-optical link for direct comparison of distant optical clocks

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of $2\times10^{-15}$ at 1 second and $4\times10^{-18}$ at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below $2\times10^{-15}$ at 1 second and $7\times10^{-17}$ at 1000 seconds. The system was available for the direct comparison of two distant $^{87}$Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

physics.optics