SearcharxivSearch

arXiv subjects

Hideki Uchiyama

Publications and source records attributed to Hideki Uchiyama.

At least 19 recordsLinked to original sources

Distinct Velocity Components in the Absorption Lines of the Neutron Star X-ray Binary AX J1745.6-2901

Accretion disks in X-ray binaries regulate mass transfer onto compact objects and drive radiative and kinetic feedback to their surroundings. Here we report X-ray spectroscopy of the eclipsing neutron star low-mass X-ray binary AX J1745.6-2901 with XRISM/Resolve. The phase-averaged Fe XXVI Lyα absorption profile exhibits two absorption minima with relative depths that are inconsistent with the theoretical Lyα1/Lyα2 doublet ratio expected from a single velocity component. We demonstrate that this profile is well described by two discrete velocity components: a blueshifted component at v~ -160 km/s and a redshifted component at v ~ +590 km/s. The significance of the redshifted component is more than 3 sigma based on a Monte-Carlo calculation. This velocity structure persists across orbital phases, disfavoring a localized origin such as a bulge or dip. The blueshifted component, well below the outer-disk escape velocity, is consistent with a slow outflow or disk atmosphere. The redshifted absorber can be explained either by infalling gas from a failed wind or by a gravitational redshift, and the present data cannot rule out either possibility. Regardless of its origin, the redshifted component is kinematically separate from the disk atmosphere and outflow. The absence of absorption at intermediate velocities further indicates a genuinely bimodal velocity distribution rather than the two ends of a single continuous flow, offering a new view of the absorbing-gas kinematics.

astro-ph.HE

Galactic absorption measured by X-ray observations of clusters of galaxies at the low Galactic latitude

The amount of the interstellar gas in the Galaxy has been conventionally estimated through observations at various wavelengths. The estimation of the total hydrogen column density (N_H) depends on assumptions such as temperature. The X-ray absorption process is the photoelectric absorption, which depends on the number of atoms to encounter X-ray photons, and hence X-ray observations would be able to derive the N_H values independently on the condition of the interstellar matter. We measured the Galactic absorption using clusters of galaxies at the low Galactic latitude. Comparing the observed N_H with the calculated N_H} values from HI and CO intensities indicates that the observed values are systematically larger than the calculated values. The observed $N_{\rm H}$ values at high Galactic latitude (N_H<10^{22} cm^{-2}) are comparable to those estimated from N_HI} and optical reddening values using the method by Willingale et al. (2013, MNRAS, 431, 394), but the values near to the Galactic plane (N_H >10^{22} cm^{-2}) are larger than the estimated ones. The dust optical depth at 353 GHz, tau_{353}, and the observed N_H values are expressed by a linear function of N_H=(1.01-1.59)x10^{26} tau_{353} cm^{-2} even at N_H >10^{23} cm^{-2}. We also confirmed a linear correlation between the optical reddening, E(B-V), and the N_H values expressed by N_H=(6.3-9.5)x10^{21} E(B-V) cm^{-2}. This work is an additional and independent test of the relation among the amount of interstellar gas, the optical depth, and the optical reddening.

astro-ph.HE

XRISM spectroscopy of a crowded Galactic center region -- III. S, Ar and Ca ISM Absorption Features in the spectrum of MAXI J1744-294

We present a comprehensive study of X-ray absorption by sulfur (S), argon (Ar), and calcium (Ca) in the interstellar medium (ISM) along the line of sight to the low-mass X-ray binary MAXI J1744$-$294, using high-resolution XRISM Resolve spectra complemented by Chandra HETG data. The analysis employs an updated ISMabs model, incorporating newly computed $R$-matrix photoabsorption cross-sections for Ca I$-$Ca III, and existing cross-sections for higher ionization states. We find that S and Ar are predominantly in low-ionization states, with S II and Ar II dominating the cold and warm ISM phases, while higher-ionization species are constrained by upper limits. Calcium is primarily detected in low-ionization states, consistent with strong depletion into dust grains, with only marginal contributions from highly ionized ions. Using the measured ionic column densities, we infer hydrogen column densities of $N_{\rm H} \sim 1.1$-$1.3 \times 10^{23}\,\mathrm{cm^{-2}}$ from S and Ar, while the Ca-based value, tracing the neutral ISM, is in agreement with these estimates, highlighting the consistency across different tracers. Our results demonstrate the diagnostic power of combining multiple elements to probe ISM ionization structure, elemental depletion, and dust composition, and provide the first X-ray constraints on calcium absorption in the interstellar medium.

astro-ph.HE

XRISM spectroscopy of a crowded Galactic center region -- II. Narrow emission lines in the Black Hole candidate MAXI J1744-294/Swift J174540.2-290037

Narrow, highly ionized X-ray emission lines in black hole low-mass X-ray binaries (BH-LMXBs) are rare and have been observed in only a few sources, during unusual, heavily obscured accretion states. We report on a detailed high-resolution spectral analysis of emission line features from the first XRISM observation of a BH-LMXB candidate in a bright soft state, MAXI J1744-294/Swift J174540.2-290037, in the central parsec region of our galaxy. The source was observed as part of an extensive, coordinated multi-wavelength campaign on its recurring X-ray outburst in early 2025. By carefully modeling the contributions of multiple point sources and diffuse emission within the XRISM/Resolve field of view, and combining these data with broadband X-ray coverage from XMM-Newton and NuSTAR (Paper I), we identified a narrow ($σ\sim 500-1000$ km s$^{-1}$), static emission component intrinsic to the system. This component likely arises from a highly ionized (log $ξ\gtrsim 5.5$) photoionized plasma in the inner disk atmosphere, and is accompanied by a weak, narrow Fe I K$α$ line at 6.4 keV. We also detected at least three narrow emission features at atypical energies between 6.7 and 7.1 keV. The lack of corresponding rest-frame atomic transitions points toward highly ionized blueshifted Fe lines with outflow velocities of $-1300$ to $-6000$ km s$^{-1}$, which we model with multiple layers of photoionized or collisional plasma. We explore scenarios in which these unprecedented features are produced by multiple phases in a jet and/or a disk wind, and discuss potential similarities between MAXI J1744- 294 and the exotic microquasar SS 433.

astro-ph.HE

XRISM spectroscopy of a crowded Galactic center region -- I. Disentangling the sources in the field of view

The Galactic center is a complex and crowded region hosting the supermassive black hole Sgr A*, numerous accreting compact objects, and diffuse X-ray emission. This paper presents the first in a series of studies analyzing the XRISM observation of the X-ray transient MAXI J1744-294/Swift J174540.2-290037, located $\sim18''$ from Sgr A*. The observation, conducted in March 2025, along with XMM-Newton and NuSTAR coverage, aimed to investigate the Fe emission features of MAXI J1744-294 during its outburst. However, the region surrounding the source is heavily contaminated by X-ray emission from various diffuse and point sources, including strong line contributions from the supernova remnant Sgr A East and the Galactic center X-ray emission (GCXE). Additionally, the nearby neutron star low-mass X-ray binary (NS-LMXB) AX J1745.6-2901 was also in outburst during the XRISM observation, further complicating the spectral analysis. This study focuses on disentangling the contributions of these overlapping sources by robustly modeling the background contamination and spatial-spectral mixing. We describe the methodologies, region selection, and data reduction techniques applied to the different instruments. Two complementary approaches -- empirical and physical modeling -- are employed to characterize diffuse emission and point-source contributions. The results provide a foundation for the detailed spectral analysis of MAXI J1744-294, AX J1745.6-2901, and the surrounding interstellar medium (ISM), which will be presented in subsequent papers. This study highlights the challenges and robust solutions for analyzing XRISM/Resolve data from crowded regions in conjunction with other X-ray telescope data.

astro-ph.HE

Narrow iron- and nickel-K absorption lines from the eclipsing low-mass X-ray binary AX~J1745.6$-$2901

We report the presence of a highly ionized absorber in the transient, eclipsing low-mass X-ray binary AX J1745.6-2901, observed from Feb. 26 to 29, 2024 with XRISM's Resolve and Xtend instruments. During a soft/high state without dips, Resolve's high spectral resolution (E/dE ~ 1000, full width at half maximum) revealed narrow velocity widths (sigma ~ 110 km/s) for Fe XXVI and Ni XXVIII lines, even with low photon statistics. These widths are consistent with binary orbital motion. The observed modest blueshift velocity (~160 km/s) indicates that the absorber is located sufficiently far from the neutron star (> 10^9 cm), so that gravitational redshift effects are not dominant. On the other hand, broad-band spectral analysis using a photoionized plasma model applied to the Xtend data constrains the absorber to lie within a radius of < 10^9.5 cm, as inferred from the upper limits of the best-fit ionization parameter (log xi ~ 4.4) and the large column density (~ 1.6 x 10^24 cm^-2). At this distance, the observed outward velocity of the absorber is about an order of magnitude smaller than the escape velocity from the neutron star.

astro-ph.HE

Spectral and photometric variability of SS 433 observed with XRISM and simultaneous optical and near-infrared telescopes

We present results from coordinated multiwavelength observations of the SS 433, obtained with XRISM, optical telescopes, and near-infrared camera during 2024 April and 2025 March. The XRISM exposures amounted to ~200 ks in 2024 and ~100 ks in 2025. With XRISM/Resolve's high spectral resolution and large effective area, we clearly resolved numerous emission lines even in short time segments, achieving improved accuracy in Doppler-shift measurements relative to earlier observations. The simultaneously obtained X-ray and optical Doppler shifts suggest a possible tendency for the optical emission to lag slightly behind the X-rays. In the Resolve data, the Doppler shifts of the two jet components exhibited apparent asymmetries, with jet speeds fluctuating around ~0.26$\pm$0.01$c$ in 2024 and ~0.30$\pm$0.01$c$ in 2025. The velocity variations indicated modulations on a timescale of ~6.3 d, with a phase offset of about -90$^{\circ}$ relative to the nutation cycle. The observed line widths and flux of the approaching and receding jets appear consistent with the expected geometrical effects, indicating systematically larger line widths in the inner regions of the jets, as proposed by Shidatsu et al. (2025). Optical light curves show flares of ~400 s in 2024 and ~1600 s in 2025, with amplitudes up to ~15% during out-of-eclipse intervals, while the XRISM/Xtend light curves show no significant variability within the overlapping intervals and given the statistical uncertainties. Near-infrared photometry in 2024, obtained during an out-of-eclipse interval at a different epoch from the optical observations, showed no flare-like variability, and the X-ray band also remained constant within uncertainties. These coordinated observations provide a foundation for future XRISM studies aimed at probing the dynamical properties of the relativistic jets in SS 433.

astro-ph.HE

XRISM High-resolution Spectroscopy of SS 433: Evidence of Decreasing Line-of-Sight Velocity Dispersion along the Jet

We report on the jet structure in SS 433 based on X-ray high resolution spectroscopy with the XRISM/Resolve. The source was observed over 5 days covering both inside and outside an eclipse of the compact object by the companion star. Doppler-shifted, ionized Fe and Ni K emission lines were resolved, as well as lower-energy lines including Si and S K lines. Time-resolved spectral analysis showed that Fe and Ni K line widths were $1020 \pm 40$ km s$^{-1}$ (corresponding the 1$σ$ width) in the eclipse phase, gradually increased during the egress, and reached $1740 \pm 30$ km s$^{-1}$ outside the eclipse. A time-averaged spectrum outside the eclipse confirmed that the Fe and Ni K lines in 5.5-9 keV are significantly broader than the Si and S K$α$ emission lines in 2--4 keV. Specifically, the width in 5.5-9 keV was measured to be $1900 \pm 80$ km s$^{-1}$, whereas the width in 2-4 keV is $1300^{+300}_{-400}$ km s$^{-1}$ for the approaching (blueshifted) jet component. These results indicate that radial velocity dispersion of the jet plasma in SS 433 decreases as it moves outward. We interpret this variation as progressive jet collimation along its axis, as suggested by Namiki et al. (2003), or a decrease in turbulence in the jet plasma flow within the X-ray emitting region. We also detected a clear difference in velocity dispersion between the approaching and receding (redshifted) jet components in the 5.5-9 keV band outside eclipse. The receding jet exhibited a smaller velocity dispersion ($1400 \pm 200$ km s$^{-1}$) than the approaching jet. Since the observation was conducted when the approaching jet was tilted toward the observer, this may suggest that the receding jet was more extensively occulted by the accretion disk.

astro-ph.HE

Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode

We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperature-versus-clock frequency trend. Comparing the time values calculated from the data and the true GPS times when the data were obtained, we confirmed that the requirement (within a 350 $μ$s error in the absolute time, accounting for both the spacecraft bus system and the ground system) was satisfied in the temperature conditions of the thermal vacuum test. We also simulated the variation of the timing accuracy in the on-orbit temperature conditions using the Hitomi on-orbit temperature data and found that the error remained within the requirement over $\sim 3 \times 10^{5}$ s. The on-orbit tests were conducted in 2023 September and October as part of the bus system checkout. The temperature versus clock frequency trend remained unchanged from that obtained in the thermal vacuum test and the observed time drift was consistent with that expected from the trend.

astro-ph.IM

In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM

We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}$@1.5 keV and $\sim310$ cm$^{2}$@6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

astro-ph.IM

Development of the Timing System for the X-Ray Imaging and Spectroscopy Mission

This paper describes the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0~ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR~B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below $15~μ$s compared to the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within $200~μ$s. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of $500~μ$s.

astro-ph.IM

New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM

The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges.

astro-ph.IM

Initial operations of the Soft X-ray Imager onboard XRISM

XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.

astro-ph.IM

Soft X-ray Imager of the Xtend system onboard XRISM

The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.

astro-ph.IM

Detection of extended X-ray emission around the PeVatron microquasar V4641 Sgr with XRISM

A recent report on the detection of very-high-energy gamma rays from V4641 Sagittarii (V4641 Sgr) up to ~0.8 peta-electronvolt has made it the second confirmed "PeVatron" microquasar. Here we report on the observation of V4641 Sgr with X-Ray Imaging and Spectroscopy Mission (XRISM) in September 2024. Thanks to the large field of view and low background, the CCD imager Xtend successfully detected for the first time X-ray extended emission around V4641 Sgr with a significance of > 4.5 sigma and > 10 sigma based on our imaging and spectral analysis, respectively. The spatial extent is estimated to have a radius of $7 \pm 3$ arcmin ($13 \pm 5$ pc at a distance of 6.2 kpc) assuming a Gaussian-like radial distribution, which suggests that the particle acceleration site is within ~10 pc of the microquasar. If the X-ray morphology traces the diffusion of accelerated electrons, this spatial extent can be explained by either an enhanced magnetic field (~80 uG) or a suppressed diffusion coefficient (~$10^{27}$ cm$^2$ s$^{-1}$ at 100 TeV). The integrated X-ray flux, (4-6)$\times 10^{-12}$ erg s$^{-1}$ cm$^{-2}$ (2-10 keV), would require a magnetic field strength higher than the galactic mean (> 8 uG) if the diffuse X-ray emission originates from synchrotron radiation and the gamma-ray emission is predominantly hadronic. If the X-rays are of thermal origin, the measured extension, temperature, and plasma density can be explained by a jet with a luminosity of ~$2\times 10^{39}$ erg s$^{-1}$, which is comparable to the Eddington luminosity of this system.

astro-ph.HE

Plasma diagnostics of supernova remnant 3C 400.2 by Suzaku observations

We report a result of plasma diagnostics of the supernova remnant (SNR) 3C 400.2, which has been reported to have a recombining plasma (RP) by previous studies. For careful background estimation, we simultaneously fitted spectra extracted from the SNR and background regions and evaluated the SNR emission contaminating the background-region spectrum as well as the background emission in the source-region spectrum. The SNR emission is explained by the collisional ionization equilibrium plasma originating from the interstellar medium and the ionizing plasma originating from the ejecta, in contrast to the previous studies. In addition, we found an unidentified X-ray source near the SNR, Suzaku J1937.4+1718, which is accompanied by an emission line at ~4.4~keV with the 2.8$σ$ confidence level. Since there is no striking atomic line at the energy in the rest frame, Suzaku J1937.4+1718 can be an extragalactic object with a redshifted Fe line.

astro-ph.HE

Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.

astro-ph.IM

Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.

astro-ph.IM