SearcharxivSearch

arXiv subjects

Hideyuki Watanabe

Publications and source records attributed to Hideyuki Watanabe.

At least 19 recordsLinked to original sources

Magnetic Microscopy of Skyrmions in Magnetic Thin Films with Chiral Overlayers

Topologically nontrivial magnetic textures such as skyrmions offer promising opportunities for spintronic applications. In recent years, it has been shown that the magnetic properties of layered materials can be affected by depositing chiral molecules on the surface, while the influence of chiral overlayers on skyrmion properties such as their stability and interactions remains largely unexplored. To address this challenge, we employ wide-field nitrogen-vacancy (NV) magnetometry to directly image skyrmions in chiral-molecule-functionalized magnetic thin films, enabling quantitative mapping of magnetic stray fields over extended areas under ambient conditions. Using pixel-resolved optically detected magnetic resonance (ODMR) combined with controlled magnetic fields, we reproducibly nucleate and probe skyrmion states in CoFeB ferromagnetic samples, enabling quantitative investigation of their properties. We find evidence for enantioselective and magnetic-field-polarity-dependent modifications of skyrmion diameter, spacing, and shape, pointing to a possibility of molecular control of topological spin textures via magneto-chiral coupling.

cond-mat.mtrl-sci

Direct measure of DNA bending by quantum magnetic imaging of a nano-mechanical torque-balance

DNA flexibility is a key determinant of biological function, from nucleosome positioning to transcriptional regulation, motivating a direct measurement of the bend-torque response of individual DNA molecules. In this work, DNA bending is detected using a nano-mechanical torque balance formed by tethering a ferromagnetic nanoparticle probe by an individual DNA molecule to a diamond magnetic field imager. The torque exerted by the DNA in response to bending caused by an applied magnetic torque is measured using wide-field imaging of quantum defects near the surface of the diamond. Qualitative measurements of differences in DNA bio-mechanical binding configuration are demonstrated, and as a proof-of-principle, a quantitative measurement of the bend response is made for individual DNA molecules. This quantum-enabled measurement approach could be applied to characterize the bend response of biophysically relevant short DNA molecules as well as the sequence dependence of DNA bending energy.

physics.bio-ph

Imaging of high-frequency electromagnetic field by multipulse sensing using nitrogen vacancy centers in diamond

Near-field enhancement of the microwave field is applied for imaging high frequency radio field using a diamond chip with an $n$-doped isotopically purified diamond layer grown by microwave plasma assisted chemical vapor deposition. A short $π$ pulse length enables us to utilize a multipulse dynamic decoupling method for detection of radio frequency field at 19.23 MHz. An extraordinary frequency resolution of the external magnetic field detection is achieved by using amplitude-shaped control pulses. Our method opens up the possibility for high-frequency-resolution RF imaging at $μ$m spatial resolution using nitrogen vacancy centers in diamond.

quant-ph

Angle dependence of $^{15}$N nuclear spin dynamics in diamond NV centers

We report on the dynamics of the Rabi oscillation and the Larmor precession of $^{15}$N nuclear spin using nonselective short microwave pulses for initialization of $^{15}$N nuclear spins. We observe the Larmor precession of $^{15}$N nuclear spin depending on the angle between the applied magnetic field and the axis of the nitrogen vacancy center. We propose to utilize the change of the Larmor frequency of the nuclear spins to detect static magnetic fields at high sensitivity. Our results may contribute to enhancing the sensitivity of dc magnetic fields and devising novel protocols using $^{15}$N nuclear spin in nitrogen vacancy centers in diamonds.

quant-ph

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution, even at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetic field sensing using continuous-wave opticallydetected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF) dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with a RF field at two different frequencies. One creates the RF dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on a RF field with a single frequency. The estimated bandwidth is 7.45 MHz, higher than that of the conventional method using the RF dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

quant-ph

Suppression of Brillouin oscillation in transparent free-standing diamond thin films in picosecond ultrasound

Brillouin oscillation appears in picosecond ultrasonics for a transparent specimen because of backward light scattering by moving strain pulse. Its amplitude is comparable with those of other responses, such as pulse-echo signals and through-thickness resonance, obscuring these non-Brillouin-oscillation responses. We here find that Brillouin oscillation can be suppressed in a transparent free-standing film by coating both sides with metallic thin film of appropriate thickness and that this peculiar behavior is caused by strain pulses generated on both sides with a slight phase difference. This phenomenon allowed us to fabricate a Brillouin-oscillation-free diamond free-standing film, which showed high capability for sensor applications.

physics.app-ph

Lattice thermal conductivity in isotope diamond asymmetric superlattices

We study lattice thermal conductivity of isotope diamond superlattices consisting of 12C and 13C diamond layers at various superlattice periods. It is found that the thermal conductivity of a superlattice is significantly deduced from that of pure diamond because of the reduction of the phonon group velocity near the folded Brillouin zone. The results show that asymmetric superlattices with different number of layers of 12C and 13C diamonds exhibit higher thermal conductivity than symmetric superlattices even with the same superlattice period, and we find that this can be explained by the trade-off between the effects of phonon specific heat and phonon group velocity. Furthermore, impurities and imperfect superlattice structures are also found to significantly reduce the thermal conductivity, suggesting that these effects can be exploited to control the thermal conductivity over a wide range.

physics.app-ph

Wide-field dynamic magnetic microscopy using double-double quantum driving of a diamond defect ensemble

Wide-field magnetometry can be realized by imaging the optically-detected magnetic resonance of diamond nitrogen vacancy (NV) center ensembles. However, NV ensemble inhomogeneities significantly limit the magnetic-field sensitivity of these measurements. We demonstrate a double-double quantum (DDQ) driving technique to facilitate wide-field magnetic imaging of dynamic magnetic fields at a micron scale. DDQ imaging employs four-tone radio frequency pulses to suppress inhomogeneity-induced variations of the NV resonant response. As a proof-of-principle, we use the DDQ technique to image the dc magnetic field produced by individual magnetic-nanoparticles tethered by single DNA molecules to a diamond sensor surface. This demonstrates the efficacy of the diamond NV ensemble system in high-frame-rate magnetic microscopy, as well as single-molecule biophysics applications.

physics.app-ph

Probing topological spin structures using light-polarization and magnetic microscopy

We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.

cond-mat.mtrl-sci

Detection and control of single proton spins in a thin layer of diamond grown by chemical vapor deposition

We report detection and coherent control of a single proton nuclear spin using an electronic spin of the nitrogen-vacancy (NV) center in diamond as a quantum sensor. In addition to determining the NV-proton hyperfine parameters by employing multipulse sequences, we polarize and coherently rotate the single proton spin, and detect an induced free precession. Observation of free induction decays is an essential ingredient for high resolution proton nuclear magnetic resonance, and the present work extends it to the atomic scale. We also discuss the origin of the proton as incorporation during chemical vapor deposition growth, which provides an opportunity to use protons in diamond as built-in quantum memories coupled with the NV center.

quant-ph

Control of all the transitions between ground state manifolds of nitrogen vacancy centers in diamonds by applying external magnetic driving fields

Nitrogen vacancy (NV) centers in diamonds is a promising system for quantum information processing and quantum sensing, and the control of the quantum state is essential for practical applications. In this study, we demonstrate a control of all the three transitions among the ground state sublevels of NV centers by applying external magnetic driving fields. To address the states of a specific NV axis among the four axes, we apply a magnetic field orthogonal to the NV axis. We control two transitions by microwave pulses and the remaining transition by radio frequency pulses. In particular, we investigate the dependence of Rabi oscillations on the frequency and intensity of the radio frequency pulses. Our results pave the way for a novel control of NV centers for the realization of quantum information processing and quantum sensing.

quant-ph

Bandwidth analysis of AC magnetic field sensing based on electronic spin double resonance of nitrogen-vacancy centers in diamond

Recently we have demonstrated AC magnetic field sensing scheme using a simple continuous-wave optically detected magnetic resonance of nitrogen-vacancy centers in diamond [Appl. Phys. Lett. 113, 082405 (2018)]. This scheme is based on electronic spin double resonance excited by continuous microwaves and radio-frequency (RF) fields. Here we measured and analyzed the double resonance spectra and magnetic field sensitivity for various frequencies of microwaves and RF fields. As a result, we observed a clear anticrossing of RF-dressed electronic spin states in the spectra and estimated the bandwidth to be approximately 5 MHz at the center frequency of 9.9 MHz.

quant-ph

Demonstration of vector magnetic field sensing by simultaneous control of nitrogen-vacancy centers in diamond using multi-frequency microwave pulses

An ensemble of nitrogen-vacancy (NV) centers in diamond is a fascinating candidate to realize a sensitive magnetic field sensor. In particular, since the axes of the NV centers are distributed along four directions, a collection of measurement data from NV centers with different axes provides information on the vector components of a magnetic field. However, in the conventional approach, the low measurement contrast of NV centers limits the sensitivity of vector magnetic field sensing. Recently, to overcome this problem, multi-frequency control of the NV centers has been proposed. The key idea is that the four types of NV centers with different axes are simultaneously controlled by multi-frequency microwave pulses. Here, we demonstrate vector magnetic field sensing with an ensemble of NV centers in diamond via such multi-frequency control with pulsed-type measurements. We use Hahn echo pulses and extract information on the vector components of an applied AC magnetic field. We find that the sensitivity of diamond-based vector field sensing with multi-frequency control is better than that with single-frequency control for every vector component of a magnetic field.

quant-ph

Detection of the phase shift of an alternating-current magnetic field by quantum sensing with multiple-pulse decoupling sequences

Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen vacancy (NV) center in diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC field can be generally obtained when the $π$-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is $π/2$. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the non-phase-accumulation condition is available for detecting a very small phase shift of an AC field from its initial phase. This finding is expected to provide a guide for realizing sensitive measurement of a complex AC magnetic field in micrometer and nanometer scales.

quant-ph

Influence of dynamical decoupling sequences with finite-width pulses on quantum sensing for AC magnetometry

Dynamical decoupling sequences with multiple pulses can be considered to exhibit filter functions for the time evolution of a qubit superposition state. They contribute to the improvement of coherence time and qubit-phase accumulation due to a time-varying field and can thus achieve high-frequency-resolution spectroscopy. Such behaviors find useful application in highly sensitive detection based on qubits for various external fields such as a magnetic field. Hence, decoupling sequences are indispensable tools for quantum sensing. In this study, we experimentally and theoretically investigated the effects of finite-width pulses in the sequences on AC magnetometry utilizing nitrogen-vacancy centers in an isotopically-controlled diamond. We revealed that the finite pulse widths cause a deviation of the optimum time to acquire the largest phase accumulation due to the sensing field from that expected by filter functions neglecting the pulse widths, even if the widths are considerably shorter than the time period of the sensing field. Moreover, we experimentally demonstrated that the deviation can be corrected by an appropriate time-frequency conversion. Our results provide a guideline for the detection of an AC field with an accurate frequency and linewidth in quantum sensing with multiple-pulse sequences.

quant-ph

Coherent control of solid state nuclear spin nano-ensembles

Detecting and controlling nuclear spin nano-ensembles is crucial for the further development of nuclear magnetic resonance (NMR) spectroscopy and for the emerging solid state quantum technology. Here we present the fabrication of a $\approx$ 1 nanometre thick diamond layer consisting of $^{13}$C nuclear spins doped with Nitrogen-Vacancy centres (NV) embedded in a spin-free $^{12}$C crystal matrix. A single NV in the vicinity of the layer is used for polarization of the $^{13}$C spins and the readout of their magnetization. We demonstrate a method for coherent control of few tens of nuclear spins by using radio frequency pulses and show the basic coherent control experiments - Rabi oscillations, Ramsey spectroscopy and Hahn echo, though any NMR pulse sequence can be implemented. The results shown present a first steps towards the realization of a nuclear spin based quantum simulator.

quant-ph

AC Magnetic Field Sensing Using Continuous-Wave Optically Detected Magnetic Resonance of Nitrogen Vacancy Centers in Diamond

Nitrogen-vacancy (NV) centers in diamond are considered sensors for detecting magnetic fields. Pulsed optically detected magnetic resonance (ODMR) is typically used to detect AC magnetic fields; however, this technique can only be implemented after careful calibration that involves aligning an external static magnetic field, measuring continuous-wave (CW) ODMR, determining the Rabi frequency, and setting the microwave phase. In contrast, CW-ODMR can be simply implemented by continuous application of green CW laser and a microwave filed. In this letter, we report a method that uses NV centers and CW-ODMR to detect AC magnetic fields. Unlike conventional methods that use NV centers to detect AC magnetic fields, the proposed method requires neither a pulse sequence nor an externally applied DC magnetic field; this greatly simplifies the procedure and apparatus needed to implement this method. This method provides a sensitivity of 2.5 μT/Hz$^{1/2}$ at room temperature. Thus, this simple alternative to existing AC magnetic field sensors paves the way for a practical and feasible quantum sensor.

quant-ph

Nitrogen-vacancy centers created by N$^+$ ion implantation through screening SiO$_2$ layers on diamond

We report on an ion implantation technique utilizing a screening mask made of SiO$_2$ to control both the depth profile and the dose. By appropriately selecting the thickness of the screening layer, this method fully suppresses the ion channeling, brings the location of the highest NV density to the surface, and effectively reduces the dose by more than three orders of magnitude. With a standard ion implantation system operating at the energy of 10 keV and the dose of 10$^{11}$ cm$^2$ and without an additional etching process, we create single NV centers close to the surface with coherence times of a few tens of $μ$s.

cond-mat.mtrl-sci