SearcharxivSearch

arXiv subjects

Hiroki Fujimoto

Publications and source records attributed to Hiroki Fujimoto.

8 recordsLinked to original sources

Adjusting optical cavity birefringence with wavelength tunable laser for axion searches

Axions have attracted attention as promising candidates for dark matter (DM). Although axions have been intensively searched for, they have not been observed yet. Recently, novel experiments to search for axion DM have been proposed that use optical cavities to amplify polarization rotation of laser light induced by the axion-photon interaction. One such experiment employs a ring cavity composed of four mirrors. However, its sensitivity to the axion-photon coupling $g_{aγ}$ in the low axion mass region is limited due to a reflection phase difference between s- and p-polarizations. In this paper, we propose a new method to improve the sensitivity using zero-phase shift mirrors and a wavelength tunable laser. Moreover, the laser makes it easier to scan the high axion mass region by tuning the reflection phase difference between s- and p-polarizations. We experimentally confirmed that the phase difference generated upon reflection on a zero phase shift mirror satisfied the requirement of $8.6 \times 10^{-3}~\mathrm{deg}$, which corresponds to the half width at half maximum (HWHM) of the cavity for p-polarization with the mirror fixed on a folded cavity and a wavelength tunable laser.

hep-ex

Searches for ultralight vector and axion dark matter with KAGRA

We have proposed using laser interferometric gravitational wave detectors to search for ultralight vector and axion dark matter. Vector dark matter can be probed through oscillating forces on suspended mirrors, while axion dark matter can be detected via oscillating polarization rotation of laser beams. This paper reviews these searches with the KAGRA detector in Japan, including the first vector dark matter search with KAGRA's 2020 data and installation of polarization optics for axion dark matter search during the upcoming 2025 observing run.

hep-ph

First results of axion dark matter search with DANCE

Axions are one of the well-motivated candidates for dark matter, originally proposed to solve the strong CP problem in particle physics. Dark matter Axion search with riNg Cavity Experiment (DANCE) is a new experimental project to broadly search for axion dark matter in the mass range of $10^{-17}~\mathrm{eV} < m_a < 10^{-11}~\mathrm{eV}$. We aim to detect the rotational oscillation of linearly polarized light caused by the axion-photon coupling with a bow-tie cavity. The first results of the prototype experiment, DANCE Act-1, are reported from a 24-hour observation. We found no evidence for axions and set 95% confidence level upper limit on the axion-photon coupling $g_{a γ} \lesssim 8 \times 10^{-4}~\mathrm{GeV^{-1}}$ in $10^{-14}~\mathrm{eV} < m_a < 10^{-13}~\mathrm{eV}$. Although the bound did not exceed the current best limits, this optical cavity experiment is the first demonstration of polarization-based axion dark matter search without any external magnetic field.

hep-ex

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

quant-ph

First observation and analysis of DANCE: Dark matter Axion search with riNg Cavity Experiment

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed to search for axion dark matter [Phys. Rev. Lett. 121, 161301 (2018)]. We aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10}~\rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is ongoing to demonstrate the feasibility of the method and to investigate technical noises. The optics was assembled and the performance of the cavity was evaluated. The first 12-day observation was successfully performed in May 2021. We reached $3 \times 10^{-6}~\rm{rad/\sqrt{Hz}}$ at $10~\rm{Hz}$ in the one-sided amplitude spectral density of the rotation angle of linear polarization.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Design and development of auxiliary cavity for simultaneous resonance of linear polarizations

Axion-like particles (ALPs) are undiscovered pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linearly polarized light. Dark matter Axion search with riNg Cavity Experiment (DANCE) searches for ALP dark matter by amplifying the rotational oscillation with a bow-tie ring cavity. Simultaneous resonance of linear polarizations is necessary to amplify both the carrier field and the ALP signal, and to achieve the design sensitivity. The sensitivity of the current prototype experiment DANCE Act-1 is less than expectation by around three orders of magnitude due to the resonant frequency difference between s- and p-polarization in the bow-tie ring cavity. In order to tune the resonant frequency difference, the method of introducing an auxiliary cavity was proposed. We designed an auxiliary cavity that can cancel out the resonant frequency difference and realize simultaneous resonance, considering optical loss. We also confirmed that the sensitivity of DANCE Act-1 with the auxiliary cavity can reach the original sensitivity.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Development of control system for long-term measurement

Axion-like particles (ALPs) are pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linear polarization. DANCE searches for ALP dark matter by enhancing the rotational oscillation in a bow-tie ring cavity. The signal to noise ratio of DANCE can be improved by long-term observation, and we are planning a year-long observation for the final DANCE. In this document, I will report on the control systems of the ring cavity we developed for the future long-term observation.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Current sensitivity

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed. To search for axion-like particles, we aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10} \, \rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is in progress to demonstrate the feasibility of the method and to investigate technical noises. We assembled the optics, evaluated the performance of the cavity, and estimated the current sensitivity. If we observe for a year, we can reach $g_{a γ} \simeq 9 \times 10^{-7} \, \rm{GeV^{-1}}$ at $m_a \simeq 10^{-13} \, \rm{eV}$. The current sensitivity was believed to be limited by laser intensity noise at low frequencies and by mechanical vibration at high frequencies.

hep-ph