Searcharxiv⌕ Search

arXiv subjects

Hironori Matsumoto

Publications and source records attributed to Hironori Matsumoto.

At least 37 records · Page 2Linked to original sources

Mapping Cassiopeia A's silicon/sulfur Doppler velocities with XRISM-Resolve

Young supernova remnants (SNRs) provide crucial insights into explosive nucleosynthesis products and their velocity distribution soon after the explosion. However, these velocities are influenced by the dynamics of the circumstellar medium (CSM), which originates from the progenitor's late-phase mass loss. Cas A, the youngest known Galactic core-collapse SNR, was studied to analyze the spatial distribution of Si and S radial velocities using two high-spectral resolution observations from the XRISM-Resolve imaging spectrometer.Resolve's capabilities enabled the detailed characterization of Si XIII, Si XIV, S XV, and S XVI lines, whose line shapes can be resolved and modeled using Gaussian radial-velocity components. The radial velocities measured generally align with previous CCD-based results, confirming that they were not artifacts caused by blended lines or ionization variations. Modeling line profiles with two-component Gaussians improved fits in some regions, revealing distinct redshifted (backside) and blueshifted (frontside) components only in a few specific areas. In most regions, however, both components were either both redshifted (northwest) or both blueshifted (southeast), consistent with the patchy ejecta shell morphology seen in optically emitting fast-moving knots. The individual line components revealed a line broadening ranging from $σ_v \approx 200$ to $σ_v \approx 2000$ km/s. Components with $1000 \lesssim σ_v \lesssim 2000$km/s are consistent with previously determined reverse shock velocities, suggesting non-equilibrated or partially equilibrated ion temperatures. Narrow components with small radial velocities found near Cas A's projected center likely originate from shocked CSM plasma. But the low radial velocity and small $σ_v$ defies identifying these components with either the frontside or backside of the SNR, or both.

astro-ph.HE↗

XRISM forecast for the Coma cluster: stormy, with a steep power spectrum

The XRISM Resolve microcalorimeter array measured the velocities of hot intracluster gas at two positions in the Coma galaxy cluster: 3'x3' squares at the center and at 6' (170 kpc) to the south. We find the line-of-sight velocity dispersions in those regions to be sigma_z=208+-12 km/s and 202+-24 km/s, respectively. The central value corresponds to a 3D Mach number of M=0.24+-0.015 and the ratio of the kinetic pressure of small-scale motions to thermal pressure in the intracluster plasma of only 3.1+-0.4%, at the lower end of predictions from cosmological simulations for merging clusters like Coma, and similar to that observed in the cool core of the relaxed cluster A2029. Meanwhile, the gas in both regions exhibits high line-of-sight velocity differences from the mean velocity of the cluster galaxies, Delta v_z=450+-15 km/s and 730+-30 km/s, respectively. A small contribution from an additional gas velocity component, consistent with the cluster optical mean, is detected along a sightline near the cluster center. The combination of the observed velocity dispersions and bulk velocities is not described by a Kolmogorov velocity power spectrum of steady-state turbulence; instead, the data imply a much steeper effective slope (i.e., relatively more power at larger linear scales). This may indicate either a very large dissipation scale resulting in the suppression of small-scale motions, or a transient dynamic state of the cluster, where large-scale gas flows generated by an ongoing merger have not yet cascaded down to small scales.

astro-ph.HE↗

Measuring the asymmetric expansion of the Fe ejecta of Cassiopeia A with XRISM/Resolve

The expansion structure of supernova remnants (SNRs) is important for understanding not only how heavy elements are distributed into space, but also how supernovae explode. The ejecta expansion structure of the young core-collapse SNR Cas A is investigated, with Doppler parameter mapping of the Fe-K complex by the Resolve microcalorimeter onboard the X-ray Imaging and Spectroscopy Mission, XRISM. It is found that the Fe ejecta are blueshifted in the southeast (SE) and redshifted in the northwest (NW), indicating an incomplete shell structure, similar to the intermediate mass elements (IMEs), such as Si and S. The Fe has a velocity shift of $\sim1400$ km~s$^{-1}$ in the NW and $\sim2160$ km~s$^{-1}$ in the SE region, with the error range of a few 100s km~s$^{-1}$. These values are consistent with those for the IMEs in the NW region, whereas larger than those for the IMEs in the SE region, although the large error region prevented us from concluding which component has significantly higher velocity. The line broadening is larger in the center with values of $\sim$2000--3000~km~s$^{-1}$, and smaller near the edges of the remnant. The radial profiles of the Doppler shift and broadening of the IMEs and Fe indicate that the Fe ejecta may expand asymmetrically as IME ejacta, although the large error regions do not allow us to conclude it. Moreover, we see little bulk Doppler broadening of the Fe lines in the northeastern jet region whereas the IME lines exhibit significant broadening. No such narrow lines are detected in the NW region. These findings suggest an asymmetric expansion of the ejecta potentially driven by large-scale asymmetries originating from the supernova explosion. This interpretation aligns with the large-scale asymmetries predicted by models of neutrino-driven supernova explosions.

astro-ph.HE↗

Evidence for Charge Exchange Emission in Supernova Remnant N132D from XRISM/Resolve Observations

XRISM has delivered one of its first light observations on N132D, the X-ray brightest supernova remnant in the Large Magellanic Cloud. Utilizing 193 ks of high-resolution X-ray spectroscopy data, we conduct a comprehensive search for charge exchange emission. By incorporating a charge exchange model into our spectral analysis, we observe an improvement in the fits of two weak features at 2.41 keV and 2.63 keV. These features, with a combined significance of 99.6%, are consistent with transitions from highly ionized silicon ions in high Rydberg states, which are unique indicators of charge exchange. Our analysis constrains the charge exchange flux to no more than 4% of the total source flux within the 1.7-3.0 keV band, and places an upper limit on the charge exchange interaction velocity at 450 km/s. This result supports ongoing shock-cloud interactions within N132D and highlights the unique capabilities of XRISM to probe the complex physical processes at play.

astro-ph.HE↗

In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM

We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}$@1.5 keV and $\sim310$ cm$^{2}$@6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

astro-ph.IM↗

New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM

The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges.

astro-ph.IM↗

Initial operations of the Soft X-ray Imager onboard XRISM

XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.

astro-ph.IM↗

Soft X-ray Imager of the Xtend system onboard XRISM

The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.

astro-ph.IM↗

NuSTAR detection of a hot stellar superflare with a temperature of 95 MK in hard X-rays

A search of the hard X-ray archive data of NuSTAR found a transient source, NuSTAR J230059+5857.4, during an observation of 1E 2259+586 on 2013 April 25. A multi-wavelength analysis using X-ray, optical, and IR data, mostly taken in its quiescent phase, was conducted to identify the origin of NuSTAR J230059+5857.4 and elucidate the phenomena associated with the flare activity. The results indicated that NuSTAR J230059+5857.4 was a stellar flare that occurred on a single M-dwarf, M-dwarf binary, or pre-main-sequence star. NuSTAR J230059+5857.4 exhibited the higher emission measure and higher temperature, 8.60+2.15/-1.73x10^54 cm^-3 and 8.21+2.71/-1.86 keV, respectively, on average than the nominal values of stellar flares reported in the past. The flare loop size estimated on the basis of the model to balance the plasma and magnetic pressures was larger than the stellar radius by a factor of several. Since based on solar flare loops, this flare loop scale is excessively large, we conjecture that the observed large emission measure is possible to be attributed to the observation of mutually-associated multiple flares simultaneously occurring on the stellar surface, known as sympathetic flares. Thanks to the large effective area of NuSTAR in the hard X-ray band, we can conduct detailed discussion about a temperature variation associated with the flare. Investigation of the temperature variation during the flare revealed that the temperature remained significantly higher than during the quiescent phase even after the count rate dropped to around 5% of the peak. The sustained high temperature over the long duration is consistent with the idea of sympathetic flares. We found that it is essential to use theoretical models to evaluate loops and assess temporal changes in temperature as done in this study to determine whether there are multiple flares or not when analyzing flare observation data.

astro-ph.SR↗

The NewAthena mission concept in the context of the next decade of X-ray astronomy

Large X-ray observatories such as Chandra and XMM-Newton have been delivering scientific breakthroughs in research fields as diverse as our Solar System, the astrophysics of stars, stellar explosions and compact objects, accreting super-massive black holes, and large-scale structures traced by the hot plasma permeating and surrounding galaxy groups and clusters. The recently launched observatory XRISM is opening in earnest the new observational window of non-dispersive high-resolution spectroscopy. However, several quests are left open, such as the effect of the stellar radiation field on the habitability of nearby planets, the Equation-of-State regulating matter in neutron stars, the origin and distribution of metals in the Universe, the processes driving the cosmological evolution of the baryons locked in the gravitational potential of Dark Matter and the impact of supermassive black hole growth on galaxy evolution, just to mention a few. Furthermore, X-ray astronomy is a key player in multi-messenger astrophysics. Addressing these quests experimentally requires an order-of-magnitude leap in sensitivity, spectroscopy and survey capabilities with respect to existing X-ray observatories. This paper succinctly summarizes the main areas where high-energy astrophysics is expected to contribute to our understanding of the Universe in the next decade and describes a new mission concept under study by the European Space Agency, the scientific community worldwide and two International Partners (JAXA and NASA), designed to enable transformational discoveries: NewAthena. This concept inherits its basic payload design from a previous study carried out until 2022, Athena.

astro-ph.IM↗

Multi-image x-ray interferometer module: II. Demonstration of high-resolution x-ray imaging with regular-interval coded apertures

We have been developing an x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally-spaced apertures and an x-ray detector. The aperture size and mask-detector distance determine the system's angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5" with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt to MIXIM a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ~50% at 12.4 keV. Consequently, the new MIXIM realizes about 25 times as large an effective area as that of the previous model, while maintaining a high angular resolution of 0.2" and a compact size of ~1.5 m.

astro-ph.IM↗

Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.

astro-ph.IM↗

Possible Supercritical Accretion on the ULX in the Metal-poor Galaxy IZw18

We present an analysis of X-ray observations of the Ultraluminous X-ray source (ULX) in IZw18 based on archival data taken with Chandra, XMM-Newton, and Suzaku. This ULX is considered to be an intermediate-mass black hole candidate simply because it is in the lowest metallicity environment among ULXs, where formation of heavy black holes is facilitated. However, actual study of the ULX based on observations spanning for a long period has been too limited to determine its nature. In this study, we investigate the spectral evolution of the ULX up to 2014, combining the previously-unpublished Suzaku data with those from the other two satellites. We derive a positive correlation of $L\propto T_{\rm in}^{2.1\pm0.4}$ between the bolometric luminosity $L$ and inner-disk temperature $T_{\rm in}$ on the basis of the multi-color disk-blackbody model, where we exclude the Chandra data, which has the lowest luminosity and systematic residuals in the fitting. The nominal relation $L\propto T_{\rm in}^{4}$ for the standard disk is rejected at a significance level of 1.5 %. These results suggest that the ULX was in the slim-disk state during these observations except at the time of the Chandra observation, in which the ULX was likely to be in a different state. The apparent inner-disk radius appears negatively correlated with the inner-disk temperature. Moreover, we find a radial dependence of the disk temperature of $T (r)\propto r^{-p}$ with $p<0.75$, which also supports the hypothesis that the ULX has a slim disk. In consequence, the IZw18 ULX is most likely to be powered by a stellar-mass compact object in supercritical accretion.

astro-ph.HE↗

Multi-Image X-ray Interferometer Module: I. design concept and proof-of-concept experiments with fine-pitch slits

We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only {\sim}1", severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5" when a configured system size was only {\sim}1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1" with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.

astro-ph.IM↗

Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.

astro-ph.IM↗

A broadband X-ray imaging spectroscopy in the 2030s: the FORCE mission

In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneous soft X-ray coverage. FORCE aims to be launched in the early 2030s, providing a perfect hard X-ray complement to the ESA flagship mission Athena. FORCE will be the most powerful X-ray probe for discovering obscured/hidden black holes and studying high energy particle acceleration in our Universe and will address how relativistic processes in the universe are realized and how these affect cosmic evolution. FORCE, which will operate over 1--79 keV, is equipped with two identical pairs of supermirrors and wideband X-ray imagers. The mirror and imager are connected by a high mechanical stiffness extensible optical bench with alignment monitor systems with a focal length of 12~m. A light-weight silicon mirror with multi-layer coating realizes a high angular resolution of $<15''$ in half-power diameter in the broad bandpass. The imager is a hybrid of a brand-new SOI-CMOS silicon-pixel detector and a CdTe detector responsible for the softer and harder energy bands, respectively. FORCE will play an essential role in the multi-messenger astronomy in the 2030s with its broadband X-ray sensitivity.

astro-ph.HE↗

Narrow Fe-K$α$ Reverberation Mapping Unveils the Deactivated Broad-Line Region in a Changing-Look Active Galactic Nucleus

"Changing-look active galactic nuclei" (CLAGNs) are known to change their apparent types between types 1 and 2, usually accompanied by a drastic change in their luminosity on timescales of years. However, it is still unclear whether materials in broad-line regions (BLRs) in CLAGNs appear and disappear during the type-transition or remain at the same location while the line production is simply activated or deactivated. Here we present our X-ray-optical monitoring results of a CLAGN, NGC 3516, by Suzaku, Swift, and ground telescopes, with our primary focus on the narrow Fe-K$α$ emission line, which is an effective probe of the BLR materials. We detected significant variations of the narrow Fe-K$α$ line on a timescale of tens of days during the type-2 (faint) phase in 2013-2014, and conducted "narrow Fe-K$α$ reverberation mapping," comparing its flux variation with those of the X-ray continuum from a corona and $B$-band continuum from an accretion disk. We derived, as a result, a time lag of $10.1^{+5.8}_{-5.6}$ days ($1σ$ errors) for the Fe-K$α$ line behind the continuum, which is consistent with the location of the BLR determined in optical spectroscopic reverberation mapping during the type-1 (bright) phase. This finding shows that the BLR materials remained at the same location without emitting optical broad-lines during the type-2 phase. Considering the drastic decrease of the radiation during the type-transition, our result is possibly inconsistent with the hotly-discussed formation models of the BLR which propose that the radiative pressure from an accretion disk should be the main driving force.

astro-ph.HE↗

X-Ray Emission from the PeVatron-candidate Supernova Remnant G106.3+2.7

We report a discovery of diffuse X-ray emission around the supernova remnant (SNR) G106.3+2.7, which is associated with VER J2227+608 and HAWC J2227+610 and is known as a candidate for a PeV cosmic ray accelerator (PeVatron). We analyze observational data of Suzaku around the SNR and the adjacent pulsar PSR J2229+6114. We find diffuse X-ray emission that is represented by either thermal or non-thermal one. However, the metal abundance for the thermal emission is <0.13 Z_sun, which may be too small in the Milky Way and suggests that the emission is non-thermal. The intensity of the diffuse emission increases toward PSR J2229+6114 in the same way as radio emission, and it is in contrast with gamma-ray emission concentrated on a molecular cloud. The X-ray photon index does not change with the distance from the pulsar and it indicates that radiative cooling is ineffective and particle diffusion is not extremely slow. The X-ray and radio emissions seem to be of leptonic origin and the parent electrons may originate from the pulsar or its wind nebula. The gamma-ray emission appears to be of hadronic origin because of its spacial distribution. The parent protons may be tightly confined in the cloud separately from the diffusing electrons.

astro-ph.HE↗