Searcharxiv⌕ Search

arXiv subjects

Hiroshi Murakami

Publications and source records attributed to Hiroshi Murakami.

At least 37 records · Page 2Linked to original sources

Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.

astro-ph.IM↗

Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.

astro-ph.IM↗

A broadband X-ray imaging spectroscopy in the 2030s: the FORCE mission

In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneous soft X-ray coverage. FORCE aims to be launched in the early 2030s, providing a perfect hard X-ray complement to the ESA flagship mission Athena. FORCE will be the most powerful X-ray probe for discovering obscured/hidden black holes and studying high energy particle acceleration in our Universe and will address how relativistic processes in the universe are realized and how these affect cosmic evolution. FORCE, which will operate over 1--79 keV, is equipped with two identical pairs of supermirrors and wideband X-ray imagers. The mirror and imager are connected by a high mechanical stiffness extensible optical bench with alignment monitor systems with a focal length of 12~m. A light-weight silicon mirror with multi-layer coating realizes a high angular resolution of $<15''$ in half-power diameter in the broad bandpass. The imager is a hybrid of a brand-new SOI-CMOS silicon-pixel detector and a CdTe detector responsible for the softer and harder energy bands, respectively. FORCE will play an essential role in the multi-messenger astronomy in the 2030s with its broadband X-ray sensitivity.

astro-ph.HE↗

Simulation-based spectral analysis of X-ray CCD data affected by photon pile-up

We have developed a simulation-based method of spectral analysis for pile-up affected data of X-ray CCDs without any loss of photon statistics. As effects of the photon pile-up appear as complicated nonlinear detector responses, we employ a detailed simulation to calculate the important processes in an X-ray observation including physical interactions, detector signal generation, detector readout, and a series of data reduction processes. This simulation naturally reproduces X-ray-like and background-like events as results of X-ray photon merging in a single pixel or in a chunk of adjacent pixels, allowing us to construct a nonlinear spectral analysis framework that can treat pile-up affected observation data. For validation, we have performed data analysis of Suzaku XIS observations by using this framework with various parameters of the detector simulation all of which are optimized for that instrument. We present three cases of different pile-up degrees: PKS~2155-304 (negligible pile-up), Aquila~X-1 (moderate pile-up), and the Crab Nebula (strong pile-up); we show that the nonlinear analysis method produces results consistent with a conventional linear analysis for the negligible pile-up condition, and accurately corrects well-known pile-up effects such as spectral hardening and flux decrease for the pile-up cases. These corrected results are consistent with those obtained by a widely used core-exclusion method or by other observatories with much higher timing resolutions (without pile-up). Our framework is applicable to any types of CCDs used for X-ray astronomy including a future mission such as XRISM by appropriate optimization of the simulation parameters.

astro-ph.IM↗

Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite

We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.

astro-ph.IM↗

Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM

We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.

astro-ph.IM↗

Inverse FIP Effects in Giant Solar Flares Found from Earth X-Ray Albedo with Suzaku/XIS

We report X-ray spectroscopic results for four giant solar flares occurred on 2005 September 7 (X17.0), 2005 September 8 (X5.4), 2005 September 9 (X6.2), and 2006 December 5 (X9.0), obtained from Earth albedo data with the X-ray imaging spectrometer (XIS) onboard Suzaku. The good energy resolution of the XIS (FWHM$\sim$100 eV) enables us to separate a number of line-like features and detect the underlying continuum emission. These features include Si He$α$, Si Ly$α$, S He$α$, S Ly$α$, Ar He$α$, and Ca He$α$ originating from solar flares as well as fluorescent Ar K$α$ and Ar K$β$ from the Earth atmosphere. Absolute elemental abundances (X/H) averaged over the four flares are obtained to be $\sim$2.0 (Ca), $\sim$0.7 (Si), $\sim$0.3 (S), and $\sim$0.9 (Ar) at around flare peaks. This abundance pattern is similar to those of active stars' coronae showing inverse first ionization potential (i-FIP) effects, i.e., elemental abundances decrease with decreasing FIP with a turnover at the low end of FIP. The abundances are almost constant during the flares, with an exception of Si which increases by a factor of $\sim$2 in the decay phase. The evolution of the Si abundance is consistent with a picture that the i-FIP plasma originates from the chromosphere evaporation and then mixes with the surrounding low-FIP biased materials. Flare-to-flare abundance varied by a factor of 2, agreeing with past observations of solar flares. Finally, we emphasize that Earth albedo data acquired by X-ray astronomy satellites like Suzaku and XRISM can significantly contribute to studies of solar physics.

astro-ph.SR↗

Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite

We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.

astro-ph.IM↗

The FORCE mission : Science aim and instrument parameter for broadband X-ray imaging spectroscopy with good angular resolution

FORCE is a 1.2 tonnes small mission dedicated for wide-band fine-imaging x-ray observation. It covers from 1 to 80 keV with a good angular resolution of $15"$ half-power-diameter. It is proposed to be launched around mid-2020s and designed to reach a limiting sensitivity as good as $F_X (10-40~{\rm keV}) = 3 \times 10^{-15}$~erg cm$^{-2}$ s$^{-1}$ keV$^{-1}$ within 1~Ms. This number is one order of magnitude better than current best one. With its high-sensitivity wide-band coverage, FORCE will probe the new science field of "missing BHs", searching for families of black holes of which populations and evolutions are not well known. Other point-source and diffuse-source sciences are also considered. FORCE will also provide the "hard x-ray coverage" to forthcoming large soft x-ray observatories.

astro-ph.IM↗

Soft X-ray Imager aboard Hitomi (ASTRO-H)

The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope, the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a $38^{\prime} \times 38^{\prime}$ field-of-view. The CCDs are P-channel fully-depleted, back-illumination type with a depletion layer thickness of $200~μ{\rm m}$. Low operation temperature down to $-120~^\circ{\rm C}$ as well as charge injection is employed to reduce the charge transfer inefficiency of the CCDs. The functionality and performance of the SXI are verified in on-ground tests. The energy resolution measured is $161$-$170~{\rm eV}$ in full width at half maximum for $5.9~{\rm keV}$ X-rays. In the tests, we found that the CTI of some regions are significantly higher. A method is developed to properly treat the position-dependent CTI. Another problem we found is pinholes in the Al coating on the incident surface of the CCDs for optical light blocking. The Al thickness of the contamination blocking filter is increased in order to sufficiently block optical light.

astro-ph.IM↗

Proton Radiation Damage Experiment on P-Channel CCD for an X-ray CCD camera onboard the Astro-H satellite

We report on a proton radiation damage experiment on P-channel CCD newly developed for an X-ray CCD camera onboard the Astro-H satellite. The device was exposed up to 10^9 protons cm^{-2} at 6.7 MeV. The charge transfer inefficiency (CTI) was measured as a function of radiation dose. In comparison with the CTI currently measured in the CCD camera onboard the Suzaku satellite for 6 years, we confirmed that the new type of P-channel CCD is radiation tolerant enough for space use. We also confirmed that a charge-injection technique and lowering the operating temperature efficiently work to reduce the CTI for our device. A comparison with other P-channel CCD experiments is also discussed.

astro-ph.IM↗

On the Radii of Brown Dwarfs Measured with AKARI Near-Infrared Spectroscopy

We derive the radii of 16 brown dwarfs observed by AKARI using their parallaxes and the ratios of observed to model fluxes. We find that the brown dwarf radius ranges between 0.64-1.13 RJ with an average radius of 0.83 RJ. We find a trend in the relation between radii and Teff; the radius is at a minimum at Teff~1600 K, which corresponds to the spectral types of mid-to late-L. The result is interpreted by a combination of radius-mass and radius-age relations that are theoretically expected for brown dwarfs older than 10^8 yr.

astro-ph.SR↗

AKARI/IRC 18 Micron Survey of Warm Debris Disks

Context. Little is known about the properties of the warm (Tdust >~ 150 K) debris disk material located close to the central star, which has a more direct link to the formation of terrestrial planets than the low temperature debris dust that has been detected to date. Aims. To discover new warm debris disk candidates that show large 18 micron excess and estimate the fraction of stars with excess based on the AKARI/IRC Mid-Infrared All-Sky Survey data. Methods. We have searched for point sources detected in the AKARI/IRC All-Sky Survey, which show a positional match with A-M dwarf stars in the Tycho-2 Spectral Type Catalogue and exhibit excess emission at 18 micron compared to that expected from the Ks magnitude in the 2MASS catalogue. Results. We find 24 warm debris candidates including 8 new candidates among A-K stars. The apparent debris disk frequency is estimated to be 2.8 +/- 0.6%. We also find that A stars and solar-type FGK stars have different characteristics of the inner component of the identified debris disk candidates --- while debris disks around A stars are cooler and consistent with steady-state evolutionary model of debris disks, those around FGK stars tend to be warmer and cannot be explained by the steady-state model.

astro-ph.EP↗

The Absence of Cold Dust around Warm Debris Disk Star HD 15407A

We report Herschel and AKARI photometric observations at far-infrared (FIR) wavelengths of the debris disk around the F3V star HD 15407A, in which the presence of an extremely large amount of warm dust (~500-600 K) has been suggested by mid-infrared (MIR) photometry and spectroscopy. The observed flux densities of the debris disk at 60-160 micron are clearly above the photospheric level of the star, suggesting excess emission at FIR as well as at MIR wavelengths previously reported. The observed FIR excess emission is consistent with the continuum level extrapolated from the MIR excess, suggesting that it originates in the inner warm debris dust and cold dust (~50-130 K) is absent in the outer region of the disk. The absence of cold dust does not support a late heavy bombardment-like event as an origin of the large amount of warm debris dust around HD 15047A.

astro-ph.EP↗

Silica-Rich Bright Debris Disk around HD 15407A

We report an intriguing debris disk towards the F3V star HD 15407A, in which an extremely large amount of warm fine dust (~ 10^(-7) M_Earth) is detected. The dust temperature is derived as ~ 500-600 K and the location of the debris dust is estimated as 0.6-1.0 AU from the central star, a terrestrial planet region. The fractional luminosity of the debris disk is ~ 0.005, which is much larger than those predicted by steady-state models of the debris disk produced by planetesimal collisions. The mid-infrared spectrum obtained by Spitzer indicates the presence of abundant micron-sized silica dust, suggesting that the dust comes from the surface layer of differentiated large rocky bodies and might be trapped around the star.

astro-ph.EP↗

Detection of X-Ray Emission from the Unidentified TeV Gamma-Ray Source TeV J2032+4130

We observed the first unidentified TeV gamma-ray source TeV J2032+4130 with Suzaku. Owing to Suzaku's high sensitivity for detection of diffuse X-ray emission, we found two small structures in the TeV emitting region. One of them is coincident with a gamma-ray pulsar PSR J2032+4127, which was discovered by the Fermi Gamma-ray Space Telescope. By subtracting contribution of point sources estimated by Chandra data, we obtained diffuse X-ray spectrum. The X-ray spectrum can be reproduced by a power-law model with a photon index of about 2, and an X-ray flux of 2x10^{-13} erg s^-1 cm^-2. The ratio of the gamma-ray flux to the X-ray flux is about 10. If the origin of the TeV gamma-ray is inverse Compton scattering of microwave background by high energy electrons, the ratio corresponds to the magnetic field strength of ~1 microG. However, the smaller size of the X-ray emission than that of the TeV emission suggests that energy loss of the electrons can explain the large ratio of the gamma-ray flux with a reasonable magnetic field strength of a few microG.

astro-ph.HE↗

The ASTRO-H Mission

The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H allows a combination of wide band X-ray spectroscopy (5-80 keV) provided by multilayer coating, focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-12 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope (0.4-12 keV) and a non-focusing soft gamma-ray detector (40-600 keV) . The micro-calorimeter system is developed by an international collaboration led by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of Delta E ~7 eV provided by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

astro-ph.IM↗

Detection of parent H2O and CO2 molecules in the 2.5--5 micron spectrum of comet C/2007 N3 (Lulin) observed with AKARI

Comet C/2007 N3 (Lulin) was observed with the Japanese infrared satellite AKARI in the near-infrared at a post-perihelion heliocentric distance of 1.7 AU. Observations were performed with the spectroscopic (2.5--5.0 micron) and imaging (2.4, 3.2, and 4.1 micron) modes on 2009 March 30 and 31 UT, respectively. AKARI images of the comet exhibit a sunward crescent-like shape coma and a dust tail extended toward the anti-solar direction. The 4.1 micron image (CO/CO2 and dust grains) shows a distribution different from the 2.4 and 3.2 micron images (H2O and dust grains). The observed spectrum shows distinct bands at 2.66 and 4.26 micron, attributed to H2O and CO2, respectively. This is the fifth comet in which CO2 has been directly detected in the near-infrared spectrum. In addition, CO at 4.67 micron and a broad 3.2--3.6 micron emission band from C-H bearing molecules were detected in the AKARI spectrum. The relative abundance ratios CO2/H2O and CO/H2O derived from the molecular production rates are \sim 4%--5% and < 2%, respectively. Comet Lulin belongs to the group that has relatively low abundances of CO and CO2 among the comets observed ever.

astro-ph.EP↗