SearcharxivSearch

arXiv subjects

Hiroshi Tsunemi

Publications and source records attributed to Hiroshi Tsunemi.

At least 19 recordsLinked to original sources

In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM

We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}$@1.5 keV and $\sim310$ cm$^{2}$@6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

astro-ph.IM

Initial operations of the Soft X-ray Imager onboard XRISM

XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.

astro-ph.IM

Soft X-ray Imager of the Xtend system onboard XRISM

The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.

astro-ph.IM

Multi-image x-ray interferometer module: II. Demonstration of high-resolution x-ray imaging with regular-interval coded apertures

We have been developing an x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally-spaced apertures and an x-ray detector. The aperture size and mask-detector distance determine the system's angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5" with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt to MIXIM a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ~50% at 12.4 keV. Consequently, the new MIXIM realizes about 25 times as large an effective area as that of the previous model, while maintaining a high angular resolution of 0.2" and a compact size of ~1.5 m.

astro-ph.IM

Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.

astro-ph.IM

Multi-Image X-ray Interferometer Module: I. design concept and proof-of-concept experiments with fine-pitch slits

We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only {\sim}1", severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5" when a configured system size was only {\sim}1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1" with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.

astro-ph.IM

Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.

astro-ph.IM

A broadband X-ray imaging spectroscopy in the 2030s: the FORCE mission

In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneous soft X-ray coverage. FORCE aims to be launched in the early 2030s, providing a perfect hard X-ray complement to the ESA flagship mission Athena. FORCE will be the most powerful X-ray probe for discovering obscured/hidden black holes and studying high energy particle acceleration in our Universe and will address how relativistic processes in the universe are realized and how these affect cosmic evolution. FORCE, which will operate over 1--79 keV, is equipped with two identical pairs of supermirrors and wideband X-ray imagers. The mirror and imager are connected by a high mechanical stiffness extensible optical bench with alignment monitor systems with a focal length of 12~m. A light-weight silicon mirror with multi-layer coating realizes a high angular resolution of $<15''$ in half-power diameter in the broad bandpass. The imager is a hybrid of a brand-new SOI-CMOS silicon-pixel detector and a CdTe detector responsible for the softer and harder energy bands, respectively. FORCE will play an essential role in the multi-messenger astronomy in the 2030s with its broadband X-ray sensitivity.

astro-ph.HE

Suzaku Detection of Solar Wind Charge Exchange Emission from a Variety of Highly-ionized Ions in an Interplanetary Coronal Mass Ejection

X-ray emission generated through solar-wind charge exchange (SWCX) is known to contaminate X-ray observation data, the amount of which is often significant or even dominant, particularly in the soft X-ray band, when the main target is comparatively weak diffuse sources, depending on the space weather during the observation. In particular, SWCX events caused by interplanetary coronal mass ejections (ICMEs) tend to be spectrally rich and to provide critical information about the metal abundance in the ICME plasma. We analyzed the SN1006 background data observed with Suzaku on 2005 September 11 shortly after an X6-class solar flare, signatures of which were separately detected together with an associated ICME. We found that the data include emission lines from a variety of highly ionized ions generated through SWCX. The relative abundances of the detected ions were found to be consistent with those in past ICME-driven SWCX events. Thus, we conclude that this event was ICME-driven. In addition, we detected a sulfur XVI line for the first time as one from the SWCX emission, the fact of which suggests that it is the most spectrally-rich SWCX event ever observed. We suggest that observations of ICME-driven SWCX events can provide a unique probe to study the population of highly-ionized ions in the plasma, which is difficult to measure in currently-available in-situ observations.

astro-ph.SR

Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite

We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.

astro-ph.IM

Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM

We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.

astro-ph.IM

Inverse FIP Effects in Giant Solar Flares Found from Earth X-Ray Albedo with Suzaku/XIS

We report X-ray spectroscopic results for four giant solar flares occurred on 2005 September 7 (X17.0), 2005 September 8 (X5.4), 2005 September 9 (X6.2), and 2006 December 5 (X9.0), obtained from Earth albedo data with the X-ray imaging spectrometer (XIS) onboard Suzaku. The good energy resolution of the XIS (FWHM$\sim$100 eV) enables us to separate a number of line-like features and detect the underlying continuum emission. These features include Si He$α$, Si Ly$α$, S He$α$, S Ly$α$, Ar He$α$, and Ca He$α$ originating from solar flares as well as fluorescent Ar K$α$ and Ar K$β$ from the Earth atmosphere. Absolute elemental abundances (X/H) averaged over the four flares are obtained to be $\sim$2.0 (Ca), $\sim$0.7 (Si), $\sim$0.3 (S), and $\sim$0.9 (Ar) at around flare peaks. This abundance pattern is similar to those of active stars' coronae showing inverse first ionization potential (i-FIP) effects, i.e., elemental abundances decrease with decreasing FIP with a turnover at the low end of FIP. The abundances are almost constant during the flares, with an exception of Si which increases by a factor of $\sim$2 in the decay phase. The evolution of the Si abundance is consistent with a picture that the i-FIP plasma originates from the chromosphere evaporation and then mixes with the surrounding low-FIP biased materials. Flare-to-flare abundance varied by a factor of 2, agreeing with past observations of solar flares. Finally, we emphasize that Earth albedo data acquired by X-ray astronomy satellites like Suzaku and XRISM can significantly contribute to studies of solar physics.

astro-ph.SR

MAXI/SSC All-sky maps from 0.7 keV to 4 keV

By accumulating data from the Solid-state Slit Camera (SSC) on board the MAXI mission for 2 years from 2009 to 2011, diffuse X-ray background maps were obtained in energies of 0.7--1.0, 1.0--2.0, and 2.0--4.0 keV. They are the first ones that were derived with a solid-state instrument, and to be compared with the previous ROSAT all sky survey result. While the SSC map in the highest energy band is dominated by point sources and the Galactic Diffuse X-ray emission, that in 0.7--1.0 keV reveals an extended X-ray structure, of which the brightness distribution is very similar to that observed with ROSAT about 20 years before. Like in the ROSAT result, the emission is dominated by a bright arc-like structure, which appears to be a part of a circle of $\sim 50^\circ$ radius centered at about $(l, b) \sim (340^\circ, 15^\circ)$. In addition, the SSC map suggests a fainter and larger ellipse, which is elongated in the north-south direction and roughly centered at the Galactic center. The spectrum of these structures is explained as thin thermal emission from a plasma, with a temperature of $\sim 0.31$ keV and an abundance of $\sim0.3$ Solar. Based on SSC observation conditions including the low Solar activity, the Solar Wind Charge Exchange signals are estimated to be negligible in the present SSC maps, as well as in the $>0.56$ keV ROSAT map. A brief discussion is given to the obtained results.

astro-ph.HE

Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite

We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.

astro-ph.IM

X-ray imaging polarimetry with a 2.5-$\mathrmμ$m pixel CMOS sensor for visible light at room temperature

X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc., and has a pixel size of 2.5 $\mathrmμ$m $\times$ 2.5 $\mathrmμ$m. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63% $\pm$ 0.07% and 15.5% $\pm$ 0.4% at 12.4 keV and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.

astro-ph.IM

Subpixel Response of SOI Pixel Sensor for X-ray Astronomy with Pinned Depleted Diode: First Result from Mesh Experiment

We have been developing a monolithic active pixel sensor, ``XRPIX``, for the Japan led future X-ray astronomy mission ``FORCE`` observing the X-ray sky in the energy band of 1-80 keV with angular resolution of better than 15``. XRPIX is an upper part of a stack of two sensors of an imager system onboard FORCE, and covers the X-ray energy band lower than 20 keV. The XRPIX device consists of a fully depleted high-resistivity silicon sensor layer for X-ray detection, a low resistivity silicon layer for CMOS readout circuit, and a buried oxide layer in between, which is fabricated with 0.2 $μ$ m CMOS silicon-on-insulator (SOI) technology. Each pixel has a trigger circuit with which we can achieve a 10 $μ$ s time resolution, a few orders of magnitude higher than that with X-ray astronomy CCDs. We recently introduced a new type of a device structure, a pinned depleted diode (PDD), in the XRPIX device, and succeeded in improving the spectral performance, especially in a readout mode using the trigger function. In this paper, we apply a mesh experiment to the XRPIX devices for the first time in order to study the spectral response of the PDD device at the subpixel resolution. We confirmed that the PDD structure solves the significant degradation of the charge collection efficiency at the pixel boundaries and in the region under the pixel circuits, which is found in the single SOI structure, the conventional type of the device structure. On the other hand, the spectral line profiles are skewed with low energy tails and the line peaks slightly shift near the pixel boundaries, which contribute to a degradation of the energy resolution.

astro-ph.IM

The FORCE mission : Science aim and instrument parameter for broadband X-ray imaging spectroscopy with good angular resolution

FORCE is a 1.2 tonnes small mission dedicated for wide-band fine-imaging x-ray observation. It covers from 1 to 80 keV with a good angular resolution of $15"$ half-power-diameter. It is proposed to be launched around mid-2020s and designed to reach a limiting sensitivity as good as $F_X (10-40~{\rm keV}) = 3 \times 10^{-15}$~erg cm$^{-2}$ s$^{-1}$ keV$^{-1}$ within 1~Ms. This number is one order of magnitude better than current best one. With its high-sensitivity wide-band coverage, FORCE will probe the new science field of "missing BHs", searching for families of black holes of which populations and evolutions are not well known. Other point-source and diffuse-source sciences are also considered. FORCE will also provide the "hard x-ray coverage" to forthcoming large soft x-ray observatories.

astro-ph.IM