Searcharxiv⌕ Search

arXiv subjects

Hiroyasu Tajima

Publications and source records attributed to Hiroyasu Tajima.

87 records · Page 5Linked to original sources

Soft Gamma-ray Detector for the ASTRO-H Mission

ASTRO-H is the next generation JAXA X-ray satellite, intended to carry instruments with broad energy coverage and exquisite energy resolution. The Soft Gamma-ray Detector (SGD) is one of ASTRO-H instruments and will feature wide energy band (40-600 keV) at a background level 10 times better than the current instruments on orbit. SGD is complimentary to ASTRO-H's Hard X-ray Imager covering the energy range of 5-80 keV. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield where Compton kinematics is utilized to reject backgrounds. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and CdTe (cadmium telluride) sensors. Good energy resolution is afforded by semiconductor sensors, and it results in good background rejection capability due to better constraints on Compton kinematics. Utilization of Compton kinematics also makes the SGD sensitive to the gamma-ray polarization, opening up a new window to study properties of gamma-ray emission processes. The ASTRO-H mission is approved by ISAS/JAXA to proceed to a detailed design phase with an expected launch in 2014. In this paper, we present science drivers and concept of the SGD instrument followed by detailed description of the instrument and expected performance.

astro-ph.IM↗

Gamma-ray Emission from Crushed Clouds in Supernova Remnants

It is shown that the radio and gamma-ray emission observed from newly-found "GeV-bright" supernova remnants (SNRs) can be explained by a model, in which a shocked cloud and shock-accelerated cosmic rays (CRs) frozen in it are simultaneously compressed by the supernova blastwave as a result of formation of a radiative cloud shock. Simple reacceleration of pre-existing CRs is generally sufficient to power the observed gamma-ray emission through the decays of neutral pions produced in hadronic interactions between high-energy protons (nuclei) and gas in the compressed-cloud layer. This model provides a natural account of the observed synchrotron radiation in SNRs W51C, W44 and IC 443 with flat radio spectral index, which can be ascribed to a combination of secondary and reaccelerated electrons and positrons.

astro-ph.HE↗

Fermi Observations of high-energy gamma-ray emissions from GRB 080916C

Observations of the long-duration Gamma-Ray Burst GRB 080916C by the Fermi Gamma-ray Burst Monitor and Large Area Telescope show that it has a single spectral form from 8 keV to 13.2 GeV. The E>100 MeV emission was ~5 s later than the E<1 MeV emission and lasted much longer even after photons with E<100 MeV became undetectable. The redshift from GROND of z~4.35 means that this GRB has the largest reported apparent isotropic gamma-ray energy release, E_{iso} ~ 8.8 x10^{54} ergs. It also sets a stringent lower limit on the GRB outflow Lorentz factor, Gamma_{min}~890, and limits the quantum gravity mass scale, M_{QG} > 1.3 x 10^{18} GeV/c^2.

astro-ph.HE↗

High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of improved spectral performance by utilizing the energy information of both side strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6, for the readout of semiconductor detectors, which is also suitable for DSDs. A new feature of the ASIC is its internal ADC function. We confirmed this function and good noise performance that reaches an equivalent noise charge of 110 e- under the condition of 3-4 pF input capacitance.

astro-ph↗

Study of Nonthermal Emission from SNR RX J1713.7-3946 with Suzaku

We present results obtained from a series of observations of the supernova remnant RX J1713.7-3946 by the Suzaku satellite. The observations cover about two-thirds of the remnant surface. We successfully detected hard X-rays up to ~ 40 keV from each pointing. The hard X-ray spectra are described by power-law functions with photon indices of ~ 3.0, which are larger than those in the energy region below 10 keV. Connection of the spatially-integrated XIS and HXD spectra clearly reveals a spectral cutoff in the 0.4--40 keV X-ray spectrum. This cutoff is interpreted to correspond to the maximum acceleration energy of electrons emitting synchrotron radiation. The wide-band coverage of Suzaku for the first time allows us to derive the parent electron spectrum in the cutoff region, which shows good agreement with theoretical predictions. The inferred cutoff energy in the spatially-integrated X-ray spectrum indicates that particle acceleration in the remnant is so efficient that it is almost at the theoretical limit, the so-called Bohm limit. Based on the Suzaku data, we present results of multi-wavelength studies from spectral and morphological points of view. The spectral energy distribution favors the hadronic scenario rather than the leptonic scenario. For the morphology studies, we compare the surface brightness maps from the Suzaku XIS and the H.E.S.S. telescope. We confirm the strong correlation between X-ray and TeV gamma-ray emission. In addition to the correlation, we found that in the bright western rim regions the X-ray emission is brighter than expected from the general X-ray to gamma-ray correlation.

astro-ph↗

PoGOLite - A High Sensitivity Balloon-Borne Soft Gamma-ray Polarimeter

We describe a new balloon-borne instrument (PoGOLite) capable of detecting 10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6 hour flight. Polarisation measurements in the soft gamma-ray band are expected to provide a powerful probe into high-energy emission mechanisms as well as the distribution of magnetic fields, radiation fields and interstellar matter. At present, only exploratory polarisation measurements have been carried out in the soft gamma-ray band. Reduction of the large background produced by cosmic-ray particles has been the biggest challenge. PoGOLite uses Compton scattering and photo-absorption in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators surrounded by a BGO anticoincidence shield and a thick polyethylene neutron shield. The narrow FOV (1.25msr) obtained with well-type phoswich detector technology and the use of thick background shields enhance the detected S/N ratio. Event selections based on recorded phototube waveforms and Compton kinematics reduce the background to that expected for a 40-100mCrab source between 25 and 50keV. A 6 hour observation on the Crab will differentiate between the Polar Cap/Slot Gap, Outer Gap, and Caustic models with greater than 5 sigma; and also cleanly identify the Compton reflection component in the Cygnus X-1 hard state. The first flight is planned for 2010 and long-duration flights from Sweden to Northern Canada are foreseen thereafter.

astro-ph↗

Detectors for Cosmic Rays on Ground and in Space

The origin of the cosmic rays has been a great mystery since they were discovered by Victor Hess in 1912. AGASA's observation of ultra-high-energy cosmic-rays (UHECR) possibly beyond the GZK (Greisen, Zatsepin and Kuzmin) cutoff stimulated the field in great deal. In addition, Kamiokande's detection of neutrinos from SN1987A and the H.E.S.S.'s detection of TeV gamma-rays from supernova remnants demonstrated the viability of neutrino and TeV gamma-ray astronomy for cosmic-ray research. A new generation of currently-operating or soon-to-be-operating detectors for charged particles, gamma-rays and neutrinos from cosmos will get us even closer to understanding the nature and origin of cosmic rays. Detectors for UHECRs, gamma rays and neutrinos are of particular importance in order to study the origins of cosmic rays since these particles are free from the deflection due to magnetic fields. Detectors for antiparticles and gamma rays would be useful to detect cosmic rays originated from the decay of the dark matter in the Universe. I will review these cosmic-ray detectors with particular attention on the differences of ground-based, balloon-borne and satellite-borne detectors.

physics.ins-det↗

Studies of Cosmic Rays with GeV Gamma Rays

We describe the role of GeV gamma-ray observations with GLAST-LAT (Gamma-ray Large Area Space Telescope - Large Area Telescope) in identifying interaction sites of cosmic-ray proton (or hadrons) with interstellar medium (ISM). We expect to detect gamma rays from neutral pion decays in high-density ISM regions in the Galaxy, Large Magellanic Cloud, and other satellite galaxies. These gamma-ray sources have been detected already with EGRET (Energetic Gamma Ray Experiment Telescope) as extended sources (eg. LMC and Orion clouds) and GLAST-LAT will detect many more with a higher spatial resolution and in a wider spectral range. We have developed a novel image restoration technique based on the Richardson-Lucy algorithm optimized for GLAST-LAT observation of extended sources. Our algorithm calculates PSF (point spread function) for each event. This step is very important for GLAST-LAT and EGRET image analysis since PSF varies more than one order of magnitude from one gamma ray to another depending on its energy as well as its impact point and angle in the instrument. The GLAST-LAT and EGRET image analysis has to cope with Poisson fluctuation due to low number of detected photons for most sources. Our technique incorporates wavelet filtering to minimize effects due to the fluctuation. Preliminary studies on some EGRET sources are presented, which shows potential of this novel image restoration technique for the identification and characterisation of extended gamma-ray sources.

astro-ph↗

Studies of EGRET sources with a novel image restoration technique

We have developed an image restoration technique based on the Richardson-Lucy algorithm optimized for GLAST-LAT image analysis. Our algorithm is original since it utilizes the PSF (point spread function) that is calculated for each event. This is critical for EGRET and GLAST-LAT image analysis since the PSF depends on the energy and angle of incident gamma-rays and varies by more than one order of magnitude. EGRET and GLAST-LAT image analysis also faces Poisson noise due to low photon statistics. Our technique incorporates wavelet filtering to minimize noise effects. We present studies of EGRET sources using this novel image restoration technique for possible identification of extended gamma-ray sources.

astro-ph↗

GLAST Tracker

The Large Area Telescope (LAT) on board the Gamma-ray Large-Area Space Telescope (GLAST) is a pair-conversion gamma-ray detector designed to explore the gamma-ray universe in the 20 MeV-300 GeV energy band. The Tracker subsystem of the LAT will perform tracking of electron and positrons to determine the origin of the gamma-ray. The design and performance of the GLAST LAT Tracker are described in this paper.

astro-ph↗

Results of a Si/CdTe Compton Telescope

We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60 keV. For energies above several hundred keV, the higher efficiency of CdTe semiconductor in comparison with Si is expected to play an important role as an absorber and a scatterer. In order to demonstrate the spectral and imaging capability of a CdTe-based Compton Telescope, we have developed a Compton telescope consisting of a stack of CdTe pixel detectors as a small scale prototype. With this prototype, we succeeded in reconstructing images and spectra by solving the Compton equation from 122 keV to 662 keV. The energy resolution (FWHM) of reconstructed spectra is 7.3 keV at 511 keV and 3.1 keV at 122 keV, respectively. The angular resolution obtained at 511 keV is measured to be 12.2 degree (FWHM).

astro-ph↗

A Prototype Si/CdTe Compton Camera and the Polarization Measurement

A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor detectors such as silicon, germanium and cadmium telluride(CdTe) have several advantages over scintillation detectors, which have been used so far. Based on the recent advances of high resolution CdTe and silicon imaging detectors, we are working on a Si/CdTe Compton camera. We have developed 64-pixel CdTe detectors with a pixel size of 2mmx2mm and double-sided Si strip detectors(DSSDs) with a position resolution of 800 micron. As a prototype Si/CdTe Compton camera, we use a DSSD as a scatterer and two CdTe pixel detectors as an absorber. In order to verify its performance, we irradiate the camera with 100% linearly polarised 170keV gamma-rays and demonstrate the system works properly as a Compton camera. The resolution of the reconstructed scattering angle is 22 degrees(FWHM). Measurement of polarization is also reported. The polarimetric modulation factor is obtained to be 43%, which is consistent with the prediction of Monte Carlo simulations.

astro-ph↗

Development of a Si/CdTe semiconductor Compton telescope

We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe semiconductor Compton telescope are reported. The Compton telescope consists of a double-sided Si strip detector (DSSD) and CdTe pixel detectors, combined with low noise analog LSI, VA32TA. With this detector, we obtained Compton reconstructed images and spectra from line gamma-rays ranging from 81 keV up to 356 keV. The energy resolution is 3.8 keV and 7.9 keV at 122 keV and 356 keV, respectively, and the angular resolution is 9.9 degrees and 5.7 degrees at 122 keV and 356 keV, respectively.

astro-ph↗

Gamma-ray Polarimetry with Compton Telescope

Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to study gamma-ray production mechanism in the universe. CdTe and Si semiconductor technologies are key technologies to realize the Compton telescope in which their high energy resolution is crucial for high angular resolution and background rejection capability. We have assembled a prototype module using a double-sided silicon strip detector and CdTe pixel detectors. In this paper, we present expected polarization performance of a proposed mission (NeXT/SGD). We also report results from polarization measurements using polarized synchrotron light and validation of EGS4 MC simulation.

astro-ph↗

Gamma-ray Polarimetry

An astrophysics application of a low noise Double-sided Silicon Strip Detector (DSSD) is described. A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in the 0.1-20 MeV energy band. Excellent energy resolution and polarization sensitivity are key features of the SMCT. We have developed prototype modules for a low noise DSSD system, which reached an energy resolution of 1.3 keV (FWHM) for 122 keV at 0 degree C. Results of a gamma-ray imaging test are also presented.

hep-ex↗