Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings

Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement. Zero echo time (ZTE) MRI visualizes cortical bone and yields FAI angles that agree with CT, but automated angle extraction remains limited. We developed and validated automated FAI angle computation from ZTE MRI and assessed agreement with expert manual measurements in a cross-sectional study (level of evidence, 3). Pelvic ZTE MRI was acquired in 73 participants (mean age 36.8 +/- 18.5 years; 51 women, 22 men), yielding 135 hips. nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks. Custom geometric algorithms computed alpha, femoral neck-shaft, Tonnis, coronal and sagittal center-edge, and acetabular version angles from inferred segmentations. Measurements on 35 test hips were compared with the mean of two radiologists' manual measures using intraclass correlation (ICC) and Bland-Altman analysis. Dice exceeded 0.96 for bone and ranged from 0.65 to 0.83 for landmarks. Median landmark error was 0.38 mm (femoral head), 0.82 mm (lateral acetabulum), and <2.5 mm (medial acetabulum, greater trochanter). Interrater ICC was excellent for acetabular version, coronal center-edge, and Tonnis (>=0.82) but poor for alpha and femoral neck-shaft. Model versus rater-mean agreement was excellent for acetabular version, coronal center-edge, and Tonnis (0.92-0.96), good for mid-acetabular sagittal center-edge (0.74), and fair for alpha (0.45) and femoral neck-shaft (0.55). Model Bland-Altman limits of agreement were narrower than interrater limits for most angles. Fully automated morphometric assessment from ZTE MRI is feasible and performs comparably to expert readers for most coverage and version angles.

physics.med-ph

Stretchable self-tuning MRI receive coils based on liquid metal technology (LiquiTune)

Magnetic resonance imaging systems rely on signal detection via radiofrequency coil arrays which, ideally, need to provide both bendability and form-fitting stretchability to conform to the imaging volume. However, most commercial coils are rigid and of fixed size with a substantial mean offset distance of the coil from the anatomy, which compromises the spatial resolution and diagnostic image quality as well as patient comfort. Here, we propose a soft and stretchable receive coil concept based on liquid metal and ultra-stretchable polymer that conforms closely to a desired anatomy. Moreover, its smart geometry provides a self-tuning mechanism to maintain a stable resonance frequency over a wide range of elongation levels. Theoretical analysis and numerical simulations were experimentally confirmed and demonstrated that the proposed coil withstood the unwanted frequency detuning typically observed with other stretchable coils (0.4% for the proposed coil as compared to 4% for a comparable control coil). Moreover, the signal-to-noise ratio of the proposed coil increased by up to 60% as compared to a typical, rigid, commercial coil.

physics.med-ph