SearcharxivSearch

arXiv subjects

Hope Fu

Publications and source records attributed to Hope Fu.

2 recordsLinked to original sources

Performance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity

We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 589~meV~$\pm$~5~meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.92~eV~$\pm$~0.02~eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also measure a nominal phonon collection efficiency of 45\%~$\pm$~3\%~(stat.)~$\pm$~6\%~(syst.) in the best performing device, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation.

physics.ins-det

X-ray spectral performance of the Sony IMX290 CMOS sensor near Fano limit after a per-pixel gain calibration

The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous challenges remain, including improving their depletion depth and identifying effective methods to calculate per-pixel gain conversion. We have tested a commercial Sony IMX290LLR CMOS sensor under X-ray light using an $^{55}$Fe radioactive source and collected X-ray photons for $\sim$15 consecutive days under stable conditions at regulated temperatures of 21{\deg}C and 26{\deg}C. At each temperature, the data set contained enough X-ray photons to produce one spectrum per pixel consisting only of single-pixel events. We determined the gain dispersion of its 2.1 million pixels using the peak fitting and the Energy Calibration by Correlation (ECC) methods. We measured a gain dispersion of 0.4\% at both temperatures and demonstrated the advantage of the ECC method in the case of spectra with low statistics. The energy resolution at 5.9 keV after the per-pixel gain correction is improved by $\gtrsim$10 eV for single-pixel and all event spectra, with single-pixel event energy resolution reaching $123.6\pm 0.2$ eV, close to the Fano limit of silicon sensors at room temperature. Finally, our long data acquisition demonstrated the excellent stability of the detector over more than 30 days under a flux of $10^4$ photons per second.

physics.ins-det