Searcharxiv⌕ Search

arXiv subjects

Hua-Chieh Shao

Publications and source records attributed to Hua-Chieh Shao.

13 recordsLinked to original sources

Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)

Time-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.

physics.med-ph↗

Prior-Adapted Progressive Time-Resolved CBCT Reconstruction Using a Dynamic Reconstruction and Motion Estimation Method

Cone-beam CT (CBCT) provides on-board volumetric anatomy for image guidance and treatment adaptation in radiotherapy. To compensate for respiration-induced anatomical motion, time-resolved CBCT is highly desired to capture the spatiotemporal anatomical variations but faces challenges in accuracy and efficiency due to substantial optimization needed in image reconstruction and motion modeling. We proposed a fast time-resolved CBCT reconstruction framework, based on a dynamic reconstruction and motion estimation method with new reconstructions initialized and conditioned on prior reconstructions in an adaptive fashion (DREME-adapt). DREME-adapt reconstructs a time-resolved CBCT sequence from a fractional standard CBCT scan while simultaneously generating a machine learning-based motion model that allows single-projection-driven intra-treatment CBCT estimation and motion tracking. Via DREME-adapt, a virtual fraction is generated from a pre-treatment 4D-CT set of each patient for a clean, 'cold-start' reconstruction. For subsequent fractions of the same patient, DREME-adapt uses pre-derived motion models and reference CBCTs as initializations to drive a 'warm-start' reconstruction, based on a lower-cost refining strategy. Three strategies: DREME-cs which drops the 'warm-start' component, DREME-adapt-vfx which uses a fixed initialization (virtual fraction's reconstruction results), and DREME-adapt-pro which initialize reconstructions through a progressive daisy chain scheme (virtual fraction for fraction 1, fraction 1 for fraction 2, and so on), were evaluated on a digital phantom study and a patient study. DREME-adapt allows fast and accurate time-resolved CBCT reconstruction and enhances the clinical adoption potential of the DREME framework.

physics.med-ph↗

TSMS-SAM2: Multi-scale Temporal Sampling Augmentation and Memory-Splitting Pruning for Promptable Video Object Segmentation and Tracking in Surgical Scenarios

Promptable video object segmentation and tracking (VOST) has seen significant advances with the emergence of foundation models like Segment Anything Model 2 (SAM2); however, their application in surgical video analysis remains challenging due to complex motion dynamics and the redundancy of memory that impedes effective learning. In this work, we propose TSMS-SAM2, a novel framework that enhances promptable VOST in surgical videos by addressing challenges of rapid object motion and memory redundancy in SAM2. TSMS-SAM2 introduces two key strategies: multi-temporal-scale video sampling augmentation to improve robustness against motion variability, and a memory splitting and pruning mechanism that organizes and filters past frame features for more efficient and accurate segmentation. Evaluated on EndoVis2017 and EndoVis2018 datasets, TSMS-SAM2 achieved the highest mean Dice scores of 95.24 and 86.73, respectively, outperforming prior SAM-based and task-specific methods. Extensive ablation studies confirm the effectiveness of multiscale temporal augmentation and memory splitting, highlighting the framework's potential for robust, efficient segmentation in complex surgical scenarios. Our source code will be available at https://github.com/apple1986/TSMS-SAM2.

cs.CV↗

Segment Anything for Video: A Comprehensive Review of Video Object Segmentation and Tracking from Past to Future

Video Object Segmentation and Tracking (VOST) presents a complex yet critical challenge in computer vision, requiring robust integration of segmentation and tracking across temporally dynamic frames. Traditional methods have struggled with domain generalization, temporal consistency, and computational efficiency. The emergence of foundation models like the Segment Anything Model (SAM) and its successor, SAM2, has introduced a paradigm shift, enabling prompt-driven segmentation with strong generalization capabilities. Building upon these advances, this survey provides a comprehensive review of SAM/SAM2-based methods for VOST, structured along three temporal dimensions: past, present, and future. We examine strategies for retaining and updating historical information (past), approaches for extracting and optimizing discriminative features from the current frame (present), and motion prediction and trajectory estimation mechanisms for anticipating object dynamics in subsequent frames (future). In doing so, we highlight the evolution from early memory-based architectures to the streaming memory and real-time segmentation capabilities of SAM2. We also discuss recent innovations such as motion-aware memory selection and trajectory-guided prompting, which aim to enhance both accuracy and efficiency. Finally, we identify remaining challenges including memory redundancy, error accumulation, and prompt inefficiency, and suggest promising directions for future research. This survey offers a timely and structured overview of the field, aiming to guide researchers and practitioners in advancing the state of VOST through the lens of foundation models.

cs.CV↗

Time-resolved dynamic CBCT reconstruction using prior-model-free spatiotemporal Gaussian representation (PMF-STGR)

Time-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection without phase sorting or binning), is highly desired for regular and irregular motion characterization, patient setup, and motion-adapted radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a Gaussian representation-based framework (PMF-STGR) for fast and accurate dynamic CBCT reconstruction. PMF-STGR comprises three major components: a dense set of 3D Gaussians to reconstruct a reference-frame CBCT for the dynamic sequence; another 3D Gaussian set to capture three-level, coarse-to-fine motion-basis-components (MBCs) to model the intra-scan motion; and a CNN-based motion encoder to solve projection-specific temporal coefficients for the MBCs. Scaled by the temporal coefficients, the learned MBCs will combine into deformation vector fields to deform the reference CBCT into projection-specific, time-resolved CBCTs to capture the dynamic motion. Due to the strong representation power of 3D Gaussians, PMF-STGR can reconstruct dynamic CBCTs in a 'one-shot' training fashion from a standard 3D CBCT scan, without using any prior anatomical or motion model. We evaluated PMF-STGR using XCAT phantom simulations and real patient scans. Metrics including the image relative error, structural-similarity-index-measure, tumor center-of-mass-error, and landmark localization error were used to evaluate the accuracy of solved dynamic CBCTs and motion. PMF-STGR shows clear advantages over a state-of-the-art, INR-based approach, PMF-STINR. Compared with PMF-STINR, PMF-STGR reduces reconstruction time by 50% while reconstructing less blurred images with better motion accuracy. With improved efficiency and accuracy, PMF-STGR enhances the applicability of dynamic CBCT imaging for potential clinical translation.

physics.med-ph↗

A dynamic reconstruction and motion estimation framework for cardiorespiratory motion-resolved real-time volumetric MR imaging (DREME-MR)

Based on a 3D pre-treatment magnetic resonance (MR) scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a motion encoder simultaneously learned during the reconstruction, DREME-MR further enables real-time volumetric MR imaging and cardiorespiratory motion tracking with minimal intra treatment k-space data. From a 3D radial-spoke-based pre-treatment MR scan, DREME-MR uses spatiotemporal implicit-neural-representation (INR) to reconstruct pre-treatment dynamic volumetric MR images (learning task 1). The INR-based reconstruction takes a joint image reconstruction and deformable registration approach, yielding a reference anatomy and a corresponding cardiorespiratory motion model. The motion model adopts a low-rank, multi-resolution representation to decompose motion fields as products of motion coefficients and motion basis components (MBCs). Via a progressive, frequency-guided strategy, DREME-MR decouples cardiac MBCs from respiratory MBCs to resolve the two distinct motion modes. Simultaneously with the pre-treatment dynamic MRI reconstruction, DREME-MR also trains an INR-based motion encoder to infer cardiorespiratory motion coefficients directly from the raw k-space data (learning task 2), allowing real-time, intra-treatment volumetric MR imaging and motion tracking with minimal k-space data (20-30 spokes) acquired after the pre-treatment MRI scan. Evaluated using data from a digital phantom (XCAT) and a human scan, DREME-MR solves real-time 3D cardiorespiratory motion with a latency of < 165 ms (= 150-ms data acquisition + 15-ms inference time), fulfilling the temporal constraint of real-time imaging.

physics.med-ph↗

A Conditional Point Cloud Diffusion Model for Deformable Liver Motion Tracking Via a Single Arbitrarily-Angled X-ray Projection

Deformable liver motion tracking using a single X-ray projection enables real-time motion monitoring and treatment intervention. We introduce a conditional point cloud diffusion model-based framework for accurate and robust liver motion tracking from arbitrarily angled single X-ray projections (PCD-Liver), which estimates volumetric liver motion by solving deformable vector fields (DVFs) of a prior liver surface point cloud based on a single X-ray image. The model is patient-specific and consists of two main components: a rigid alignment model to estimate the liver's overall shifts and a conditional point cloud diffusion model that further corrects for liver surface deformations. Conditioned on motion-encoded features extracted from a single X-ray projection via a geometry-informed feature pooling layer, the diffusion model iteratively solves detailed liver surface DVFs in a projection angle-agnostic manner. The liver surface motion estimated by PCD-Liver serves as a boundary condition for a U-Net-based biomechanical model to infer internal liver motion and localize liver tumors. A dataset of ten liver cancer patients was used for evaluation. The accuracy of liver point cloud motion estimation was assessed using root mean square error (RMSE) and 95th-percentile Hausdorff distance (HD95), while liver tumor localization error was quantified using center-of-mass error (COME). The mean (standard deviation) RMSE, HD95, and COME of the prior liver or tumor before motion estimation were 8.82(3.58) mm, 10.84(4.55) mm, and 9.72(4.34) mm, respectively. After PCD-Liver motion estimation, the corresponding values improved to 3.63(1.88) mm, 4.29(1.75) mm, and 3.46(2.15) mm. Under highly noisy conditions, PCD-Liver maintained stable performance. This study presents an accurate and robust framework for deformable liver motion estimation and tumor localization in image-guided radiotherapy.

physics.med-ph↗

FDDM: Unsupervised Medical Image Translation with a Frequency-Decoupled Diffusion Model

Diffusion models have demonstrated significant potential in producing high-quality images in medical image translation to aid disease diagnosis, localization, and treatment. Nevertheless, current diffusion models have limited success in achieving faithful image translations that can accurately preserve the anatomical structures of medical images, especially for unpaired datasets. The preservation of structural and anatomical details is essential to reliable medical diagnosis and treatment planning, as structural mismatches can lead to disease misidentification and treatment errors. In this study, we introduce the Frequency Decoupled Diffusion Model (FDDM) for MR-to-CT conversion. FDDM first obtains the anatomical information of the CT image from the MR image through an initial conversion module. This anatomical information then guides a subsequent diffusion model to generate high-quality CT images. Our diffusion model uses a dual-path reverse diffusion process for low-frequency and high-frequency information, achieving a better balance between image quality and anatomical accuracy. We extensively evaluated FDDM using public datasets for brain MR-to-CT and pelvis MR-to-CT translations, demonstrating its superior performance to other GAN-based, VAE-based, and diffusion-based models. The evaluation metrics included Frechet Inception Distance (FID), Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM). FDDM achieved the best scores on all metrics for both datasets, particularly excelling in FID, with scores of 25.9 for brain data and 29.2 for pelvis data, significantly outperforming other methods. These results demonstrate that FDDM can generate high-quality target domain images while maintaining the accuracy of translated anatomical structures.

eess.IV↗

Real-time CBCT Imaging and Motion Tracking via a Single Arbitrarily-angled X-ray Projection by a Joint Dynamic Reconstruction and Motion Estimation (DREME) Framework

Real-time cone-beam computed tomography (CBCT) provides instantaneous visualization of patient anatomy for image guidance, motion tracking, and online treatment adaptation in radiotherapy. While many real-time imaging and motion tracking methods leveraged patient-specific prior information to alleviate under-sampling challenges and meet the temporal constraint (< 500 ms), the prior information can be outdated and introduce biases, thus compromising the imaging and motion tracking accuracy. To address this challenge, we developed a framework (DREME) for real-time CBCT imaging and motion estimation, without relying on patient-specific prior knowledge. DREME incorporates a deep learning-based real-time CBCT imaging and motion estimation method into a dynamic CBCT reconstruction framework. The reconstruction framework reconstructs a dynamic sequence of CBCTs in a data-driven manner from a standard pre-treatment scan, without utilizing patient-specific knowledge. Meanwhile, a convolutional neural network-based motion encoder is jointly trained during the reconstruction to learn motion-related features relevant for real-time motion estimation, based on a single arbitrarily-angled x-ray projection. DREME was tested on digital phantom simulation and real patient studies. DREME accurately solved 3D respiration-induced anatomic motion in real time (~1.5 ms inference time for each x-ray projection). In the digital phantom study, it achieved an average lung tumor center-of-mass localization error of 1.2$\pm$0.9 mm (Mean$\pm$SD). In the patient study, it achieved a real-time tumor localization accuracy of 1.8$\pm$1.6 mm in the projection domain. DREME achieves CBCT and volumetric motion estimation in real time from a single x-ray projection at arbitrary angles, paving the way for future clinical applications in intra-fractional motion management.

physics.med-ph↗

Prior Frequency Guided Diffusion Model for Limited Angle (LA)-CBCT Reconstruction

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy. Reconstructing CBCTs from limited-angle acquisitions (LA-CBCT) is highly desired for improved imaging efficiency, dose reduction, and better mechanical clearance. LA-CBCT reconstruction, however, suffers from severe under-sampling artifacts, making it a highly ill-posed inverse problem. Diffusion models can generate data/images by reversing a data-noising process through learned data distributions; and can be incorporated as a denoiser/regularizer in LA-CBCT reconstruction. In this study, we developed a diffusion model-based framework, prior frequency-guided diffusion model (PFGDM), for robust and structure-preserving LA-CBCT reconstruction. PFGDM uses a conditioned diffusion model as a regularizer for LA-CBCT reconstruction, and the condition is based on high-frequency information extracted from patient-specific prior CT scans which provides a strong anatomical prior for LA-CBCT reconstruction. Specifically, we developed two variants of PFGDM (PFGDM-A and PFGDM-B) with different conditioning schemes. PFGDM-A applies the high-frequency CT information condition until a pre-optimized iteration step, and drops it afterwards to enable both similar and differing CT/CBCT anatomies to be reconstructed. PFGDM-B, on the other hand, continuously applies the prior CT information condition in every reconstruction step, while with a decaying mechanism, to gradually phase out the reconstruction guidance from the prior CT scans. The two variants of PFGDM were tested and compared with current available LA-CBCT reconstruction solutions, via metrics including PSNR and SSIM. PFGDM outperformed all traditional and diffusion model-based methods. PFGDM reconstructs high-quality LA-CBCTs under very-limited gantry angles, allowing faster and more flexible CBCT scans with dose reductions.

physics.med-ph↗

Dynamic CBCT Imaging using Prior Model-Free Spatiotemporal Implicit Neural Representation (PMF-STINR)

Dynamic cone-beam computed tomography (CBCT) can capture high-spatial-resolution, time-varying images for motion monitoring, patient setup, and adaptive planning of radiotherapy. However, dynamic CBCT reconstruction is an extremely ill-posed spatiotemporal inverse problem, as each CBCT volume in the dynamic sequence is only captured by one or a few X-ray projections. We developed a machine learning-based technique, prior-model-free spatiotemporal implicit neural representation (PMF-STINR), to reconstruct dynamic CBCTs from sequentially acquired X-ray projections. PMF-STINR employs a joint image reconstruction and registration approach to address the under-sampling challenge. Specifically, PMF-STINR uses spatial implicit neural representation to reconstruct a reference CBCT volume, and it applies temporal INR to represent the intra-scan dynamic motion with respect to the reference CBCT to yield dynamic CBCTs. PMF-STINR couples the temporal INR with a learning-based B-spline motion model to capture time-varying deformable motion during the reconstruction. Compared with previous methods, the spatial INR, the temporal INR, and the B-spline model of PMF-STINR are all learned on the fly during reconstruction in a one-shot fashion, without using any patient-specific prior knowledge or motion sorting/binning. PMF-STINR was evaluated via digital phantom simulations, physical phantom measurements, and a multi-institutional patient dataset featuring various imaging protocols (half-fan/full-fan, full sampling/sparse sampling, different energy and mAs settings, etc.). The results showed that the one-shot learning-based PMF-STINR can accurately and robustly reconstruct dynamic CBCTs and capture highly irregular motion with high temporal (~0.1s) resolution and sub-millimeter accuracy. It can be a promising tool for motion management by offering richer motion information than traditional 4D-CBCTs.

physics.med-ph↗

Zero-shot Medical Image Translation via Frequency-Guided Diffusion Models

Recently, the diffusion model has emerged as a superior generative model that can produce high quality and realistic images. However, for medical image translation, the existing diffusion models are deficient in accurately retaining structural information since the structure details of source domain images are lost during the forward diffusion process and cannot be fully recovered through learned reverse diffusion, while the integrity of anatomical structures is extremely important in medical images. For instance, errors in image translation may distort, shift, or even remove structures and tumors, leading to incorrect diagnosis and inadequate treatments. Training and conditioning diffusion models using paired source and target images with matching anatomy can help. However, such paired data are very difficult and costly to obtain, and may also reduce the robustness of the developed model to out-of-distribution testing data. We propose a frequency-guided diffusion model (FGDM) that employs frequency-domain filters to guide the diffusion model for structure-preserving image translation. Based on its design, FGDM allows zero-shot learning, as it can be trained solely on the data from the target domain, and used directly for source-to-target domain translation without any exposure to the source-domain data during training. We evaluated it on three cone-beam CT (CBCT)-to-CT translation tasks for different anatomical sites, and a cross-institutional MR imaging translation task. FGDM outperformed the state-of-the-art methods (GAN-based, VAE-based, and diffusion-based) in metrics of Frechet Inception Distance (FID), Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM), showing its significant advantages in zero-shot medical image translation.

eess.IV↗

3D cine-magnetic resonance imaging using spatial and temporal implicit neural representation learning (STINR-MR)

The reconstruction of 3D cine-MRI is challenged by highly undersampled k-space data in each cine frame, due to the slow speed of MR signal acquisition. We proposed a machine learning-based framework, spatial and temporal implicit neural representation learning (STINR-MR), for accurate 3D cine-MRI reconstruction from highly undersampled data. STINR-MR used a joint reconstruction and deformable registration approach to address the ill-posed spatiotemporal reconstruction problem, by solving a reference-frame 3D MR image and a corresponding motion model which deforms the reference frame to each cine frame. The reference-frame image was reconstructed as a spatial implicit neural representation (INR) network, which learns the mapping from input 3D spatial coordinates to corresponding MR values. The dynamic motion model was constructed via a temporal INR, as well as basis deformation vector fields(DVFs) extracted from prior/onboard 4D-MRIs. The learned INR encodes input time points and outputs corresponding weighting factors to combine the basis DVFs into time-resolved motion fields. STINR-MR was evaluated using MR data simulated from the 4D extended cardiac-torso (XCAT) digital phantom and MR data acquired clinically from a healthy human subject. Its reconstruction accuracy was also compared with that of the model-based non-rigid motion estimation method (MR-MOTUS). STINR-MR can reconstruct 3D cine-MR images with high temporal (<100 ms) and spatial (3 mm) resolutions to accurately capture different irregular motion patterns. Compared with MR-MOTUS, STINR-MR consistently reconstructed images with better quality, fewer artifacts, and achieved superior tumor localization accuracy. STINR-MR provides a lightweight and efficient framework for accurate 3D cine-MRI reconstruction, and does not require external data for pre-training to avoid generalizability issues encountered in deep learning methods.

physics.med-ph↗