SearcharxivSearch

arXiv subjects

Huadong Sun

Publications and source records attributed to Huadong Sun.

2 recordsLinked to original sources

Response-Based Frequency Stability Assessment under Multi-Scale Disturbances in High-Renewable Power Systems

In high-renewable power systems, active-power disturbances are becoming larger and exhibit increasingly diverse time scales, which complicates frequency stability assessment under unanticipated events. This paper presents a response-based frequency stability assessment method that uses disturbance power, inferred from generator electrical responses, to provide a unified treatment of multi-scale disturbances. Unanticipated disturbances are first classified into short-term and permanent events; permanent disturbances are further divided into step, second-level slope and minute-level slope disturbances. Based on the measured power responses of generator groups, a unified disturbance-power model is constructed to identify the disturbance type online and to quantify disturbance intensity through the disturbance power and its rate of change. Analytical frequency-response models are then derived for each disturbance class. For step disturbances, the maximum tolerable disturbance power is obtained under steady-state and transient frequency deviation constraints, and a safety-margin index is defined. For slope-type disturbances, an improved system frequency response (SFR) model and the rotor motion equation after exhaustion of primary frequency regulation are used to compute the over-limit time of frequency deviation. The proposed response-based assessment method is validated on the CSEE-FS frequency-stability benchmark system, demonstrating its effectiveness and accuracy for quantitative frequency stability assessment in high-renewable power systems.

eess.SY

Transient Stability of Low-Inertia Power Systems with Inverter-Based Generation

This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a delta-power-frequency model is developed. Based on this model, new mechanisms of transient instability different from those of conventional power systems from the energy perspective are discovered. First, two loss-of-synchronization (LOS) types are identified based on the relative power imbalance owing to the mismatch between the inertia of the IBG and SG under a fault. Second, the relative angle and frequency will jump at the moment of a fault, thus affecting the system energy. Third, the cosine damping coefficient induces a positive energy dissipation, thereby contributing to the system stability. A unified criterion for identifying the two LOS types is proposed using the energy function method. This criterion is proved to be a sufficient stability condition for addressing the effects of the jumps and cosine damping coefficient on the system stability. The new mechanisms and effectiveness of the criterion are verified based on simulation results.

eess.SY