SearcharxivSearch

arXiv subjects

Huangchao Shi

Publications and source records attributed to Huangchao Shi.

2 recordsLinked to original sources

Lab and Beam Tests of a SiPM-readout ASIC with a Large Dynamic Range

A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large dynamic range for the readout of the silicon photomultiplier (SiPM), has been tested in the laboratory and at a test beam facility. The fundamental performance metrics have been characterised, including response linearity, inter-calibration factor and noise performance. To quantitatively assess the dynamic range of the chip and evaluate its feasibility for SiPM readout in high-granularity crystal ECAL, a beamtest was conducted using scintillating crystals exposed to electron beams. Beamtest results showed that the chip exhibits a promising performance in terms of a good signal-to-noise ratio and a relatively large dynamic range.

physics.ins-det

DIRC-like time-of-flight detector for the experiment at the Super Tau-Charm Facility

The Super Tau-Charm Facility (STCF) is a future electron-positron collider proposed in China with a peak luminosity of above 0.5$\times$10$^{35}$ cm$^{-2}$s$^{-1}$ and center-of-mass energy ranging from 2 to 7 GeV. An excellent particle identification (PID) capability is one of the most important requirements for the detector at the STCF. A 3$σ$ $π$/K separation power at the momentum of up to 2 GeV/c is required within the detector acceptance. A DIRC-like time-of-flight (DTOF) detector is proposed to meet the PID requirement for the endcap region of the STCF. The conceptual design of the DTOF detector and its geometry optimization is herein presented. The PID performance of the detector is studied using Geant4 simulation. With a proper reconstruction algorithm, an overall time resolution of ~50 ps is achieved for the detector with an optimum geometry when convoluting contributions from all other sources, including the transit time spread (TTS) of the photodetector, electronic timing accuracy, and an assumed precision (~40 ps) of the event start time. A $π$/K separation power of better than 4$σ$ at the momentum of 2 GeV/c is achieved over the entire sensitive area of the DTOF detector, thereby fulfilling the physics requirement of the PID detector for the experiment at the STCF.

physics.ins-det