Publications and source records attributed to Huiqiao Xie.

8 recordsLinked to original sources

CBCT-Based Synthetic CT Generation Using Conditional Flow Matching Model

Daily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld unit (HU). It is essential to enhance CBCT image quality to a level comparable with that of conventional CT scans. This study proposed a conditional flow matching model that gradually transforms a sample from normal distribution to the corresponding CT sample conditioned on the input CBCT image. The proposed model was trained using CBCT and deformed planning CT (dpCT) image pairs in a supervised learning scheme. The feasibility of the conditional flow matching model was verified using studies of brain, head-and-neck (HN), and lung patients. The quantitative performance was evaluated using three metrics, including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). The proposed flow matching model was also compared to other flow matching and diffusion-based generative models for sCT generation. The proposed flow matching model effectively reduced multiple types of artifacts on CBCT images in all the studies. In the study of brain patient, the MAE, PSNR, and NCC of the sCT were improved to 26.02 HU, 32.35 dB, and 0.99, respectively, from 40.63 HU, 27.87 dB, and 0.98 on the CBCT images. In the study of HN patient, the metrics were improved to 33.17 HU, 28.68 dB, 0.98 from 38.99 HU, 27.00 dB, 0.98. In the lung patient study, the metrics were 25.09 HU, 32.81 dB, 0.99 and 32.90 HU, 30.48 dB, 0.98 for sCT and CBCT, respectively. The proposed conditional flow matching model effectively synthesizes high-quality CT-like images from CBCT, achieving accurate HU representation and artifact reduction. This enables more reliable organ segmentation and dose calculation in CBCT-guided online ART workflows.

physics.med-ph

Low-Dose CT Imaging Using a Regularization-Enhanced Efficient Diffusion Probabilistic Model

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting real-time applicability. We propose a Regularization-Enhanced Efficient Diffusion Probabilistic Model (RE-EDPM), a rapid and high-fidelity LDCT denoising framework that integrates a residual shifting mechanism to align low-dose and full-dose distributions and performs only four reverse diffusion steps using a Swin-based U-Net backbone. A composite loss combining pixel reconstruction, perceptual similarity (LPIPS), and total variation (TV) regularization effectively suppresses spatially varying noise while preserving anatomical structures. RE-EDPM was evaluated on a public LDCT benchmark across dose levels and anatomical sites. On 10 percent dose chest and 25 percent dose abdominal scans, it achieved SSIM = 0.879 (0.068), PSNR = 31.60 (2.52) dB, VIFp = 0.366 (0.121) for chest, and SSIM = 0.971 (0.000), PSNR = 36.69 (2.54) dB, VIFp = 0.510 (0.007) for abdomen. Visual and statistical analyses, including ablation and Wilcoxon signed-rank tests (p < 0.05), confirm significant contributions from residual shifting and regularization terms. RE-EDPM processes two 512x512 slices in about 0.25 s on modern GPUs, supporting near real-time clinical use. The proposed framework achieves an optimal balance between noise suppression and anatomical fidelity, offering an efficient solution for LDCT restoration and broader medical image enhancement tasks.

physics.med-ph

Limited-Angle CBCT Reconstruction via Geometry-Integrated Cycle-domain Denoising Diffusion Probabilistic Models

Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts, blurring, and increased dose. This work aims to develop a clinically feasible method for reconstructing high-quality CBCT volumes from consecutive limited-angle acquisitions, addressing imaging challenges in time- or dose-constrained settings. We propose a limited-angle (LA) geometry-integrated cycle-domain (LA-GICD) framework for CBCT reconstruction, comprising two denoising diffusion probabilistic models (DDPMs) connected via analytic cone-beam forward and back projectors. A Projection-DDPM completes missing projections, followed by back-projection, and an Image-DDPM refines the volume. This dual-domain design leverages complementary priors from projection and image spaces to achieve high-quality reconstructions from limited-angle (<= 90 degrees) scans. Performance was evaluated against full-angle reconstruction. Four board-certified medical physicists conducted assessments. A total of 78 planning CTs in common CBCT geometries were used for training and evaluation. The method achieved a mean absolute error of 35.5 HU, SSIM of 0.84, and PSNR of 29.8 dB, with visibly reduced artifacts and improved soft-tissue clarity. LA-GICD's geometry-aware dual-domain learning, embedded in analytic forward/backward operators, enabled artifact-free, high-contrast reconstructions from a single 90-degree scan, reducing acquisition time and dose four-fold. LA-GICD improves limited-angle CBCT reconstruction with strong data fidelity and anatomical realism. It offers a practical solution for short-arc acquisitions, enhancing CBCT use in radiotherapy by providing clinically applicable images with reduced scan time and dose for more accurate, personalized treatments.

cs.CV

Spatiotemporal Gaussian Optimization for 4D Cone Beam CT Reconstruction from Sparse Projections

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition. The challenge lies in the sparse sampling of projections, which introduces severe streaking artifacts and compromises image quality. This paper introduces a novel framework leveraging spatiotemporal Gaussian representation for 4D-CBCT reconstruction from sparse projections, achieving a balance between streak artifact reduction, dynamic motion preservation, and fine detail restoration. Each Gaussian is characterized by its 3D position, covariance, rotation, and density. Two-dimensional X-ray projection images can be rendered from the Gaussian point cloud representation via X-ray rasterization. The properties of each Gaussian were optimized by minimizing the discrepancy between the measured projections and the rendered X-ray projections. A Gaussian deformation network is jointly optimized to deform these Gaussian properties to obtain a 4D Gaussian representation for dynamic CBCT scene modeling. The final 4D-CBCT images are reconstructed by voxelizing the 4D Gaussians, achieving a high-quality representation that preserves both motion dynamics and spatial detail. The code and reconstruction results can be found at https://github.com/fuyabo/4DGS_for_4DCBCT/tree/main

physics.med-ph

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from LA projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for X-ray spectra measurement or paired datasets for model training. Purpose: This work aims to facilitate the clinical applications of fast and low-dose DECBCT by developing a practical solution for image reconstruction in LA-DECBCT. Methods: An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in LA-DECBCT. By enforcing the similarity between the DE images, LA artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using four physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Conclusions: The proposed method achieves accurate image reconstruction without the need for X-ray spectra measurement for optimization or paired datasets for model training, showing great practical value in clinical implementations of LA-DECBCT.

physics.med-ph

Image-Domain Material Decomposition for Dual-energy CT using Unsupervised Learning with Data-fidelity Loss

Background: Dual-energy CT (DECT) and material decomposition play vital roles in quantitative medical imaging. However, the decomposition process may suffer from significant noise amplification, leading to severely degraded image signal-to-noise ratios (SNRs). While existing iterative algorithms perform noise suppression using different image priors, these heuristic image priors cannot accurately represent the features of the target image manifold. Although deep learning-based decomposition methods have been reported, these methods are in the supervised-learning framework requiring paired data for training, which is not readily available in clinical settings. Purpose: This work aims to develop an unsupervised-learning framework with data-measurement consistency for image-domain material decomposition in DECT.

physics.med-ph

One-step Iterative Estimation of Effective Atomic Number and Electron Density for Dual Energy CT

Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment planning, besides material-selective images, maps of effective atomic number (Z) and relative electron density to that of water ($ρ_e$) can also be achieved and further employed to improve stopping power ratio accuracy and reduce range uncertainty. In this work, we propose a one-step iterative estimation method, which employs multi-domain gradient $L_0$-norm minimization, for Z and $ρ_e$ maps reconstruction. The algorithm was implemented on GPU to accelerate the predictive procedure and to support potential real-time adaptive treatment planning. The performance of the proposed method is demonstrated via both phantom and patient studies.

physics.med-ph

Deformable Image Registration using Unsupervised Deep Learning for CBCT-guided Abdominal Radiotherapy

CBCTs in image-guided radiotherapy provide crucial anatomy information for patient setup and plan evaluation. Longitudinal CBCT image registration could quantify the inter-fractional anatomic changes. The purpose of this study is to propose an unsupervised deep learning based CBCT-CBCT deformable image registration. The proposed deformable registration workflow consists of training and inference stages that share the same feed-forward path through a spatial transformation-based network (STN). The STN consists of a global generative adversarial network (GlobalGAN) and a local GAN (LocalGAN) to predict the coarse- and fine-scale motions, respectively. The network was trained by minimizing the image similarity loss and the deformable vector field (DVF) regularization loss without the supervision of ground truth DVFs. During the inference stage, patches of local DVF were predicted by the trained LocalGAN and fused to form a whole-image DVF. The local whole-image DVF was subsequently combined with the GlobalGAN generated DVF to obtain final DVF. The proposed method was evaluated using 100 fractional CBCTs from 20 abdominal cancer patients in the experiments and 105 fractional CBCTs from a cohort of 21 different abdominal cancer patients in a holdout test. Qualitatively, the registration results show great alignment between the deformed CBCT images and the target CBCT image. Quantitatively, the average target registration error (TRE) calculated on the fiducial markers and manually identified landmarks was 1.91+-1.11 mm. The average mean absolute error (MAE), normalized cross correlation (NCC) between the deformed CBCT and target CBCT were 33.42+-7.48 HU, 0.94+-0.04, respectively. This promising registration method could provide fast and accurate longitudinal CBCT alignment to facilitate inter-fractional anatomic changes analysis and prediction.

eess.IV