SearcharxivSearch

arXiv subjects

Hunter C. Meyer

Publications and source records attributed to Hunter C. Meyer.

4 recordsLinked to original sources

Analyzer-less X-ray Interferometry with Super-Resolution Methods

X-ray interferometry provides valuable information in terms of attenuation, small-angle scatter, and differential-phase contrast. This multi-modal contrast can aid in many clinical applications, such as lung diseases and breast cancer. However, standard interferometry has an analyzer grating that can increase the dose requirement to maintain the same image quality as a standard X-ray. We propose the use of super-resolution methods for X-ray grating interferometry without an analyzer, with detectors that fail to meet the Nyquist sampling rate needed for traditional image recovery algorithms. Detector phase steps are used to nominally recover the fringe sampling, followed by iterative recovery of the visibility and object parameters. This method enables Talbot-Lau interferometry without the X-ray absorbing analyzer. Removing the absorbing analyzer grating may improve dose efficiency and reduce system complexity. We demonstrate the use of super-resolution methods to iteratively reconstruct attenuation, differential-phase, and dark-field images using simulations of two-dimensional lung phantoms with lesions. A direct CdTe detector was simulated with pixel sizes of 55, 75, and 150 micron. The simulation results show that the proposed super-resolution iterative reconstruction method for Talbot-Lau Interferometry remains stable under the simulated noise conditions and can recover image parameters in cases where traditional algorithms cannot be used.

physics.optics

Moiré Artifact Reduction in Grating Interferometry Using Multiple Harmonics and Total Variation Regularization

X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung imaging. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the attenuation, differential-phase, and dark-field images, respectively. Inaccuracies in grating position and multi-harmonic fringes produce Moiré artifacts when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. We have developed an image recovery algorithm that estimates the true phase stepping positions using multiple harmonics and total variation regularization, removing the Moiré artifacts present in the attenuation, differential-phase, and dark-field images. We demonstrate the algorithm's utility for the Talbot-Lau and Modulated Phase Grating Interferometers by imaging multiple samples, including PMMA microspheres and a euthanized mouse.

physics.optics

Dark-Field X-Ray Imaging Significantly Improves Deep-Learning based Detection of Synthetic Early-Stage Lung Tumors in Preclinical Models

Low-dose computed tomography (LDCT) is the current standard for lung cancer screening, yet its adoption and accessibility remain limited. Many regions lack LDCT infrastructure, and even among those screened, early-stage cancer detection often yield false positives, as shown in the National Lung Screening Trial (NLST) with a sensitivity of 93.8 percent and a false-positive rate of 26.6 percent. We aim to investigate whether X-ray dark-field imaging (DFI) radiograph, a technique sensitive to small-angle scatter from alveolar microstructure and less susceptible to organ shadowing, can significantly improve early-stage lung tumor detection when coupled with deep-learning segmentation. Using paired attenuation (ATTN) and DFI radiograph images of euthanized mouse lungs, we generated realistic synthetic tumors with irregular boundaries and intensity profiles consistent with physical lung contrast. A U-Net segmentation network was trained on small patches using either ATTN, DFI, or a combination of ATTN and DFI channels. Results show that the DFI-only model achieved a true-positive detection rate of 83.7 percent, compared with 51 percent for ATTN-only, while maintaining comparable specificity (90.5 versus 92.9 percent). The combined ATTN and DFI input achieved 79.6 percent sensitivity and 97.6 percent specificity. In conclusion, DFI substantially improves early-tumor detectability in comparison to standard attenuation radiography and shows potential as an accessible, low-cost, low-dose alternative for pre-clinical or limited-resource screening where LDCT is unavailable.

physics.med-ph

Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections

X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina.

physics.optics