SearcharxivSearch

arXiv subjects

Hyeongjun Cho

Publications and source records attributed to Hyeongjun Cho.

2 recordsLinked to original sources

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

cs.CV

Revisiting Pose Sensitivity in Splat-based Computed Tomography under Sparse-view Reconstruction

X-ray computed tomography (CT) reconstructs volumetric representations of objects from projection images obtained by transmitting X-rays through a target. Recent splat-based tomography, which represents a volume as a continuous distribution of 3D Gaussians, has demonstrated both high reconstruction quality and fast convergence in cone-beam sparse-view CT. However, when deployed in real CT systems with limited and non-uniform view distributions, we observe distinctive streak and strip artifacts that are far more pronounced than in conventional reconstruction methods. Through detailed analysis, we show that these artifacts primarily originate from pose inaccuracies in the acquisition geometry rather than from view sparsity itself. We revisit pose sensitivity in the splatting formulation and derive a stable gradient-based framework that jointly refines geometric parameters during reconstruction. Our study not only identifies how pose perturbations propagate through the differentiable projection operator but also reveals why splat-based CT is particularly vulnerable to geometric misalignment. The resulting formulation remains lightweight and easily integrable into existing pipelines while substantially improving reconstruction fidelity under real-world sparse-view conditions.

cs.CV