Searcharxiv⌕ Search

arXiv subjects

Hyun Woo Park

Publications and source records attributed to Hyun Woo Park.

2 recordsLinked to original sources

Closing the Quality Gap in Low-Resource Text-to-Speech: LoRA Fine-Tuning of VoxCPM2 for Khmer and Korean

Large pretrained text-to-speech (TTS) models sound almost human for well-resourced languages, but much worse for languages that are rare in their training data. We study this quality gap for Khmer and Korean using VoxCPM2, a 2.4B parameter, tokenizer-free TTS model that joins a MiniCPM-4 language-model backbone with a flow-matching diffusion decoder. We build one shared, language-tagged corpus of 25.5 hours after cleaning and adapt VoxCPM2 with a single Low-Rank Adaptation (LoRA) adapter, trained on both languages at once and added to both the language model and the decoder. The adapter is zero-initialized, so training starts exactly at the original zero-shot model. In native-speaker listening tests, the Khmer Mean Opinion Score (MOS) rises from 3.85 to 4.23 with the best adapter, rank 64. This gain is highly significant under a paired Wilcoxon test with p < 0.001, and it is achieved while training only 0.19 to 3.03 percent of the parameters. Two findings stand out. First, the training loss and human ratings disagree on the best rank. The loss is lowest at rank 128, but MOS peaks at rank 64. Second, the same adapter gives no significant gain for Korean, which the base model already covers well, and a high rank even hurts quality. This shows that adaptation helps mainly where the base model is truly weak.

cs.CL↗

Characterization of the 20-inch Photomultiplier Tubes for RENE Detector

To address the Reactor Antineutrino Anomaly (RAA) observed in neutrino experiments, the Reactor Experiment for Neutrino and Exotics (RENE) has been initiated using a liquid scintillation detector. In this study, we investigate the characteristics of two 20-inch Hamamatsu R12860 photomultiplier tubes (PMTs) intended for installation in the RENE detector. The charge and timing responses of the PMTs were evaluated at both the nominal and target gains expected during actual operation. In particular, gain non-uniformity arising from the large-diameter photocathode with a box-and-line type dynode structure was examined, and the maximum gain variation was measured. The occurrence rate, timing, and charge distributions of late pulses and afterpulses were also investigated to characterize the specific response features of the R12860 PMT. The results reported in this study will aid in the interpretation of signals from the RENE detector and serve as a reference for estimating potential systematic uncertainties in RENE data. Furthermore, these findings are expected to provide valuable information for other experiments employing the same type of PMTs.

physics.ins-det↗