SearcharxivSearch

arXiv subjects

Hyun-Keun Kwon

Publications and source records attributed to Hyun-Keun Kwon.

3 recordsLinked to original sources

Extracting the lifetime of a synthetic two-level system

The Kerr Parametric Oscillator (KPO) is a nonlinear resonator system that is often described as a synthetic two-level system. In the presence of noise, the system switches between two states via a fluctuating trajectory in phase space, instead of following a straight path. The presence of such fluctuating trajectories makes it hard to establish a precise count or even a useful definition, of the "lifetime" of the state. Addressing this issue, we compare several rate counting methods that allow to estimate a lifetime for the levels. In particular, we establish that a peak in the Allan variance of fluctuations can also be used to determine the levels' lifetime. Our work provides a basis for characterizing KPO networks for simulated annealing where an accurate determination of the state lifetime is of fundamental importance.

cond-mat.mes-hall

Dispersive readout of a high-Q encapsulated micromechanical resonator

Encapsulated bulk mode microresonators in the megahertz range are used in commercial timekeeping and sensing applications but their performance is limited by the current state of the art of readout methods. We demonstrate a readout using dispersive coupling between a high-Q encapsulated bulk mode micromechanical resonator and a lumped element microwave resonator that is implemented with commercially available components and standard printed circuit board fabrication methods and operates at room temperature and pressure. A frequency domain measurement of the microwave readout system yields a displacement resolution of $522 \, \mathrm{fm/\sqrt{Hz}}$, which demonstrates an improvement over the state of the art of displacement measurement in bulk-mode encapsulated microresonators. This approach can be readily implemented in cryogenic measurements, allowing for future work characterizing the thermomechanical noise of encapsulated bulk mode resonators at cryogenic temperatures.

physics.app-ph

On the effect of linear feedback and parametric pumping on a resonators frequency stability

Resonant sensors based on Micro- and Nano-Electro Mechanical Systems (M/NEMS) are ubiquitous in many sensing applications due to their outstanding performance capabilities, which are directly proportional to the quality factor (Q) of the devices. We address here a recurrent question in the field: do dynamical techniques that modify the effective Q (namely parametric pumping and direct drive velocity feedback) affect the performance of said sensors? We develop analytical models of both cases, while remaining in the linear regime, and introduce noise in the system from two separate sources: thermomechanical and amplifier (read-out) noise. We observe that parametric pumping enhances the quality factor in the amplitude response, but worsens it in the phase response on the resonator. In the case of feedback, we find that Q is enhanced in both cases. Then, we establish a solution for the noisy problem with direct drive and parametric pumping simultaneously. We also find that, in the case when thermomechanical noise dominates, no benefit can be obtained from neither artificial Q-enhancement technique. However, in the case when amplifier noise dominates, we surprisingly observe that a significant advantage can only be achieved using parametric pumping in the squeezing region.

cond-mat.mes-hall