SearcharxivSearch

arXiv subjects

I-Ping Chen

Publications and source records attributed to I-Ping Chen.

2 recordsLinked to original sources

Feasibility of Extracting Skin Nerve Activity from Electrocardiogram Recorded at A Low Sampling Frequency

Skin nerve activity (SKNA) derived from electrocardiogram (ECG) signals has been a promising non-invasive surrogate for accurate and effective assessment of the sympathetic nervous system (SNS). Typically, SKNA extraction requires a higher sampling frequency than the typical ECG recording requirement (> 2 kHz) because analysis tools extract SKNA from the 0.5-1 kHz frequency band. However, ECG recording systems commonly provide a sampling frequency of 1 kHz or lower, particularly for wearable devices. Our recent power spectral analysis exhibited that 150-500 Hz frequency bands are dominant during sympathetic stimulation. Therefore, we hypothesize that SKNA can be extracted from ECG sampled at a lower sampling frequency. We collected ECG signals from 16 participants during SNS stimulation and resampled the signals at 0.5, 1, and 4 kHz. Our statistical analyses of significance, classification performance, and reliability indicate no significant difference between SKNA indices derived from ECG signals sampled at 0.5, 1, and 4 kHz. Our findings indicate that conventional ECG devices, which are limited to low sampling rates due to resource constraints or outdated guidelines, can be used to reliably collect SKNA if muscle artifact contamination is minimal.

eess.SP

A Novel Approach to Characterize Dynamics of ECG-Derived Skin Nerve Activity via Time-Varying Spectral Analysis

Assessment of the sympathetic nervous system (SNS) is one of the major approaches for studying affective states. Skin nerve activity (SKNA) derived from high-frequency components of electrocardiogram (ECG) signals has been a promising surrogate for assessing the SNS. However, current SKNA analysis tools have shown high variability across study protocols and experiments. Hence, we propose a time-varying spectral approach based on SKNA to assess the SNS with higher sensitivity and reliability. We collected ECG signals at a sampling frequency of 10 KHz from sixteen subjects who underwent various SNS stimulations. Our spectral analysis revealed that frequency bands between 150 - 1,000 Hz showed significant increases in power during SNS stimulations. Using this information, we developed a time-varying index of sympathetic function measurement based on SKNA, termed, Time-Varying Skin Nerve Activity (TVSKNA). TVSKNA is calculated in three steps: time-frequency decomposition, reconstruction using selected frequency bands, and smoothing. TVSKNA indices exhibited generally higher Youden's J, balanced accuracy, and area under the receiver operating characteristic curve, indicating higher sensitivity. The coefficient of variance was lower with TVSKNA indices for most SNS tasks. TVSKNA can serve as a highly sensitive and reliable marker of quantitative assessment of sympathetic function, especially during emotion and stress.

eess.SP