SearcharxivSearch

arXiv subjects

I. Badhrees

Publications and source records attributed to I. Badhrees.

At least 19 recordsLinked to original sources

Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-$\beta$ decay detector (~5 metric ton, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5-8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

hep-ph

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.

physics.ins-det

Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

hep-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2\nu\beta\beta$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2\nu\beta\beta$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2\nu}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$\nu \beta \beta$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$\nu \beta \beta$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_\chi = 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex

Search for the decay $B_s^0\rightarrow\eta\eta$

We report results from a search for the decay $B_s^0\rightarrow\eta\eta$ using 121.4 fb$^{-1}$ of data collected at the $\Upsilon(5S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider. We do not observe any signal and set an upper limit on the branching fraction of $14.3\times 10^{-5}$ at $90\%$ confidence level. This result represents a significant improvement over the previous most stringent limit.

hep-ex

Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.

hep-ex

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

physics.ins-det

NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity

The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

nucl-ex

Measurement of ${\mathcal B}$($B_s \rightarrow D_s X$) with $B_s$ Semileptonic Tagging

We report the first direct measurement of the inclusive branching fraction ${\mathcal B}(B_s \rightarrow D_s X)$ via $B_s$ tagging in $e^+e^-\to\Upsilon$(5S) events. Tagging is accomplished through a partial reconstruction of semileptonic decays $B_s \rightarrow D_s X \ell \nu$, where $X$ denotes unreconstructed additional hadrons or photons and $\ell$ is an electron or muon. With 121.4 fb$^{-1}$ of data collected at the $\Upsilon$(5S) resonance by the Belle detector at the KEKB asymmetric-energy $e^+ e^-$ collider, we obtain ${\mathcal B}(B_s \rightarrow D_s X)$ = $(60.2 \pm 5.8 \pm 2.3)$\%, where the first uncertainty is statistical and the second is systematic.

hep-ex

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of M\"unster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45{\deg} angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20{\deg} for the four samples and increases to up to 65% at 70{\deg} for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det

Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage

nEXO is a proposed tonne-scale neutrinoless double beta decay ($0\nu\beta\beta$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $\gamma$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $\alpha$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.

physics.ins-det

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.

physics.ins-det

Evidence for a vector charmonium-like state in $e^+e^- \to D^+_sD^*_{s2}(2573)^-+c.c.$

We report the measurement of $e^+e^- \to D^+_sD^*_{s2}(2573)^-+c.c.$ via initial-state radiation using a data sample of an integrated luminosity of 921.9 fb$^{-1}$ collected with the Belle detector at the $Υ(4S)$ and nearby. We find evidence for an enhancement with a 3.4$σ$ significance in the invariant mass of $D^+_sD^*_{s2}(2573)^- +c.c.$ The measured mass and width are $(4619.8^{+8.9}_{-8.0}({\rm stat.})\pm2.3({\rm syst.}))~{\rm MeV}/c^{2}$ and $(47.0^{+31.3}_{-14.8}({\rm stat.})\pm4.6({\rm syst.}))~{\rm MeV}$, respectively. The mass, width, and quantum numbers of this enhancement are consistent with the charmonium-like state at 4626 MeV/$c^2$ recently reported by Belle in $e^+e^-\to D^+_sD_{s1}(2536)^-+c.c.$ The product of the $e^+e^-\to D^+_sD^*_{s2}(2573)^-+c.c.$ cross section and the branching fraction of $D^*_{s2}(2573)^-\to{\bar D}^0K^-$ is measured from $D^+_sD^*_{s2}(2573)^-$ threshold to 5.6 GeV.

hep-ex

Dalitz analysis of $D^{0}\to K^{-}\pi^{+}\eta$ decays at Belle

We present the results of the first Dalitz plot analysis of the decay $D^{0}\to K^{-}\pi^{+}\eta$. The analysis is performed on a data set corresponding to an integrated luminosity of 953 $\rm{fb}^{-1}$ collected by the Belle detector at the asymmetric-energy $e^{+}e^{-}$ KEKB collider. The Dalitz plot is well described by a combination of the six resonant decay channels $\bar{K}^{*}(892)^0\eta$, $K^{-}a_0(980)^+$, $K^{-}a_2(1320)^+$, $\bar{K}^{*}(1410)^0\eta$, $K^{*}(1680)^-\pi^{+}$ and $K_2^{*}(1980)^-\pi^{+}$, together with $K\pi$ and $K\eta$ S-wave components. The decays $K^{*}(1680)^{-}\to K^{-}\eta$ and $K_{2}^{*}(1980)^{-}\to K^{-}\eta$ are observed for the first time. We measure ratio of the branching fractions, $\frac{\mathcal{B}(D^{0}\to K^{-}\pi^{+}\eta)}{\mathcal{B}(D^{0}\to K^{-}\pi^{+})}=0.500\pm0.002{\rm(stat)}\pm0.020{\rm(syst)}\pm0.003{\rm (\mathcal{B}_{PDG})}$. Using the Dalitz fit result, the ratio $\frac{\mathcal{B}(K^{*}(1680)\to K\eta)}{\mathcal{B}(K^{*}(1680)\to K\pi)}$ is measured to be $0.11\pm0.02{\rm(stat)}^{+0.06}_{-0.04}{\rm(syst)}\pm0.04{\rm(\mathcal{B}_{\text{PDG}})}$; this is much lower than the theoretical expectations ($\approx1$) made under the assumption that $K^{*}(1680)$ is a pure $1^{3}D_1$ state. The product branching fraction $\mathcal{B}(D^0\to [K_2^{*}(1980)^-\to K^{-}\eta]\pi^{+})=(2.2^{+1.7}_{-1.9})\times10^{-4}$ is determined. In addition, the $\pi\eta^{\prime}$ contribution to the $a_0(980)^{\pm}$ resonance shape is confirmed with 10.1$\sigma$ statistical significance using the three-channel Flatt\'{e} model. We also measure $\mathcal{B}(D^0\to\bar{K}^{*}(892)^0\eta)=(1.41^{+0.13}_{-0.12})\%$. This is consistent with, and more precise than, the current world average $(1.02\pm0.30)\%$, deviates with a significance of more than $3\sigma$ from the theoretical predictions of (0.51-0.92)%.

hep-ex

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $\beta$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $\beta$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

nucl-ex