SearcharxivSearch

arXiv subjects

I. Giomataris

Publications and source records attributed to I. Giomataris.

At least 19 recordsLinked to original sources

Response of a nitrogen-filled spherical proportional counter to mono-energetic neutrons

Neutron spectroscopy is an invaluable tool for a wide range of scientific and industrial applications, however, current approaches suffer from limitations that restrict their field of applicability. A safe and inexpensive alternative approach to neutron detection and spectroscopy is the use of a nitrogen-filled spherical proportional counter that exploits the $^{14}\rm{N(n,p)}^{14}\rm{C}$ and $^{14}\rm{N(n},α)^{11}\rm{B}$ reactions. The neutron spectroscopy capabilities of the detector are demonstrated using beams of mono-energetic neutrons. A nitrogen-filled spherical proportional counter, operating at a pressure of $1$ bar, is exposed to neutrons with energies from $0.75$ MeV to $2.75$ MeV at the Tandem accelerator of the National Centre for Scientific Research ``Demokritos'' in Athens. A linear energy response is observed, within the statistical precision of the measurements.

hep-ex

A Novel Hadronic Calorimeter With A Direct Neutron Readout

A neutron-sensitive sampling calorimeter based on alternating lead absorber and gadolinium-loaded liquid scintillator layers is investigated using detailed Geant4 Monte Carlo simulations. In addition to the conventional prompt calorimetric signal, the proposed detector records delayed energy from neutron moderation and capture, providing direct information on the neutron component of hadronic showers. A six-layer Pb/LAB-Gd calorimeter exposed to 10~GeV protons is studied to characterize its neutron response and evaluate its impact on calorimetric performance. The delayed deposited energy is found to be almost perfectly proportional to the neutron-capture multiplicity, providing a direct calibration of the neutron-sensitive signal. Event-by-event analyses further reveal a clear relationship between the prompt calorimetric response and the delayed neutron observable, demonstrating that the latter contains substantial information on the invisible hadronic energy. Exploiting this correlation through a simple nonlinear event-by-event correction improves the prompt-energy resolution from 21.8% to 13.3% without rejecting events. Furthermore, the analysis of events with similar neutron multiplicities indicates that neutron-production fluctuations constitute a major contribution to the overall hadronic energy resolution. These results demonstrate the potential of gadolinium-loaded sampling calorimeters to recover part of the invisible hadronic energy and significantly improve hadronic energy reconstruction and energy resolution.

physics.ins-det

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $σ<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $σ= 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $σ\approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10MΩ resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200kΩ) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Search for solar axions produced through the axion-electron coupling $g_{ae}$ using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling $(g_{ae})$ using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017-2018. Using machine learning techniques and the veto systems, we achieved a background rate of $1.06\times 10^{-5}\,\text{keV}^{-1}\text{cm}^{-2}\text{s}^{-1}$ at a signal efficiency of about $80\,\%$ in the $0.2$-$8\,\text{keV}$ range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of $g_{ae}\cdot g_{aγ} < 7.35\times 10^{-23}\,\text{GeV}^{-1}$ at $95\,\%$ confidence level. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of $g_{aγ} < 9.0\times 10^{-11}\,\text{GeV}^{-1}$ at $95\,\%$ CL, which, while not surpassing CAST's best limit, provides complementary constraints on axion models.

hep-ex

The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV

The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.

hep-ex

Search for Light Dark Matter with NEWS-G at the Laboratoire Souterrain de Modane Using a Methane Target

The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.

hep-ex

The ionization yield in a methane-filled spherical proportional counter

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent campaign with a 135 cm diameter SPC filled with methane. While in situ calibrations of the detector response were carried out at the LSM, measurements of the mean ionization yield and fluctuations of methane gas in SPCs were performed using a 30 cm diameter detector. The results of multiple measurements taken at different operating voltages are presented. A UV laser system was used to measure the mean gas gain of the SPC, along with $\mathrm{^{37}Ar}$ and aluminum-fluorescence calibration sources. These measurements will inform the energy response model of future operating detectors.

physics.ins-det

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector

Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95% signal-encircling region during the new run, while 0.75 are expected. The new data improve the axion-photon coupling limit to 5.8$\times 10^{-11}\,$GeV$^{-1}$ at 95% C.L. (for $m_a \lesssim 0.02$ eV), the most restrictive experimental limit to date.

hep-ex

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det

Measurement of scintillation from proportional electron multiplication in liquid xenon using a needle

Charge amplification in liquids could provide single-phase xenon time projection chambers with background discrimination and fiducialisation capabilities similar to those found in dual-phase detectors. Although efforts to achieve the high electric field required for charge amplification and proportional scintillation in liquid xenon have been previously reported, their application to large-scale detectors remains elusive. This work presents a new approach to this challenge, where - instead of the thin wire approach of previous studies - a needle-like high-voltage electrode is employed to demonstrate proportional charge amplification and secondary scintillation production in liquid xenon. This is an important milestone towards the development of an electrode structure that could be utilised in a large-scale, single-phase time projection chamber with dual read-out.

physics.ins-det