SearcharxivSearch

arXiv subjects

I. Gonin

Publications and source records attributed to I. Gonin.

13 recordsLinked to original sources

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R&D efforts, there are no gravitational wave (GW) experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at Deutsches Elektronen-Synchrotron (DESY) and at the Superconducting Quantum Materials and Systems (SQMS) Center at Fermi National Accelerator Laboratory (Fermilab) to search for high-frequency GWs in the frequency range of 10 kHz to 100 MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R&D to operate a cavity using a low level RF (LLRF) system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8 K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

physics.acc-ph

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

physics.acc-ph

Gridded RF Gun Design for SRF Linac Applications

The thermionic gridded gun is described which generates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measurements, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current interception in the SRF cavity.

physics.acc-ph

Beam Dynamics simulations for ERDC project -- SRF linac for industrial use

Compact conductively cooled SRF industrial linacs can provide unique parameters of the electron beam for industrial applications. (up to 10MeV, 1MW). For ERDC project we designed normal conducting RF injector with thermal RF gridded gun integrated in first cell of multi-cell cavities. For design of the RF gun we used MICHELLE software to simulate and optimize parameters of the beam. Output file was converted to ASTRA format and most beam dynamic simulations in multi-cell normal conducting cavity and cryomodule were performed by using ASTRA software. For cross-checking we compare results of MICHELLE and AS-TRA in first few cells. At the end of injector beam reach ~250keV energy which allow to trap bunch in acceleration regime without losses in TESLA like 1.3 GHz cavity. Short solenoid at the end of injector allow to regulate transverse beam size in cryomodule to match beam to extraction system and also reduce charge losses in accelerator.

physics.acc-ph

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

physics.acc-ph

The Evaluation of Mechanical Properties of LB650 Cavities

The PIP-II project's LB650 cavities could potentially be vulnerable to mechanical deformation because of the geometric shape of the cavity due to reduced beta. The mechanical property of the niobium half-cell was measured following various heat treatments. The 5-cell cavities were tested in a controlled drop test fashion and the real-world road test. The result showed that the 900 $°$C heat treatment was compatible with cavity handling and transportation during production. The test provides the bases of the transportation specification and shipping container design guidelines.

physics.acc-ph

Measurement of high quality factor superconducting cavities in tesla-scale magnetic fields for dark matter searches

In dark matter searches using axion haloscopes, the search sensitivity depends on the quality factors ($Q_0$) of radiofrequency cavities immersed in multi-tesla magnetic fields. Increasing $Q_0$ would increase the scan rate through the parameter space of interest. Researchers developing superconducting radiofrequency cavities for particle accelerators have developed methods for obtaining extremely high $Q_0\sim10^{11}$ in $μ$T-scale magnetic fields. In this paper, we describe efforts to develop high Q cavities made from Nb$_3$Sn films using a technique developed for particle accelerator cavities. Geometry optimization for this application is explored, and two cavities are tested: an existing particle accelerator-style cavity and a geometry developed and fabricated for use in high fields. A quality factor of ($5.3\pm0.3$)$\times 10^5$ is obtained at 3.9~GHz and 6~T at 4.2~K.

physics.acc-ph

Validation of the 650 MHZ SRF tuner on the low and high beta cavities for PIP-II at 2 K*

The PIP-II linac will include thirty-six beta=0.61 and twenty-four beta=0.92 650 MHz 5 cell elliptical SRF cavities. Each cavity will be equipped with a tuning system consisting of a double lever slow tuner for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. The same tuner will be used for both the beta=0.61 and beta=0.92 cavities. Results of testing the cavity-tuner system for the beta=0.61 will be presented for the first time.

physics.acc-ph

Design of a medium energy, high average power superconducting e-beam accelerator for environmental applications

We present the technical and engineering design of a medium energy (10 MeV) and high average power (1 MW) electron beam accelerator intended for irradiation treatment of high volume industrial and municipal wastewater. The accelerator uses superconducting radiofrequency (SRF) cavity technology for producing the high average beam power with $>$90% RF to beam efficiency. The design of the accelerator is simplified and tailored for industrial settings by adopting the cryocooler conduction-cooling technique for the SRF cavity instead of a conventional liquid helium bath cryo-system. The technical design is supplemented with a detailed analysis of capital and operating cost of the accelerator. The designed accelerator can treat up to 12 million gallons per day of wastewater, requires capital of $\sim\$$8M for construction, and has $\sim$13.5 cents/ton/kGy in material processing cost.

physics.acc-ph

Ring-Based Electron Cooling System for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction linac technology with a dc electron beam. The system would operate in a full energy range of proton beams (100 - 270 GeV) and would provide 50-100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30$\%$. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1-2 hours.

physics.acc-ph

Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\sim$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.

physics.acc-ph

High Gradient Tests of the Fermilab SSR1 Cavity

In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavities were manufactured in the industry and on-going cold test results will be presented in this poster.

physics.acc-ph

CW RF system of the Project-X accelerator front end

Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 MeV to 160 MeV. SC Single Spoke Resonators (SSR) will be used in the linac, because Fermilab already successfully developed and tested a SSR for beta=0.21. Two manufactured cavities achieve 2.5 times more than design accelerating gradients. One of these cavities completely dressed, e.g. welded to helium vessel with integrated slow and fast tuners, and tested in CW regime. Successful tests of beta=0.21 SSR give us a confidence to use this type of cavity for low beta (0.117) and for high-beta (0.4) as well. Both types of these cavities are under development. In present report the basic constrains, parameters, electromagnetic and mechanical design for all the three SSR cavities, and first test results of beta=0.21 SSR are presented.

physics.acc-ph