SearcharxivSearch

arXiv subjects

I. Guinn

Publications and source records attributed to I. Guinn.

8 recordsLinked to original sources

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{\beta\beta} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det

First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

The LEGEND collaboration is searching for neutrinoless double beta ($0\nu\beta\beta$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0\nu\beta\beta$ decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV kg yr) in the $0\nu\beta\beta$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0\nu\beta\beta$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0\nu}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{\beta\beta} < 75-200$ meV, depending on the adopted nuclear matrix element.

hep-ex

LEGEND-1000 Preconceptual Design Report

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $\beta \beta$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.

physics.ins-det

Current status of LEGEND: Searching for Neutrinoless Double-Beta Decay in 76Ge: Part II

Neutrinoless double-beta decay (0$νββ$) decay is a hypothetical process that violates lepton number, and whose observation would unambiguously indicate that neutrinos are Majorana fermions. In the standard inverted-ordering neutrino mass scenario, the minimum possible value of mbb corresponds to a half-life around 10$^{28}$ yr for 0$νββ$ decay in $^{76}$Ge, which is the target of the next generation of experiments. The current limits of GERDA and MAJORANA DEMONSTRATOR indicate a half-life higher than 10$^{26}$ yr. These experiments use high-purity germanium (HPGe) detectors that are highly enriched in $^{76}$Ge. They have achieved the best intrinsic energy resolution and the lowest background rate in the signal search region among all 0nbb experiments. Taking advantage of these successes, a new international collaboration - the Large Enriched Germanium Experiment for Neutrinoless bb Decay (LEGEND) - has been formed to build, following a phased approach, a ton-scale experiment with discovery potential covering the inverse-ordering neutrino mass range in a decade. The first part of LEGEND proceedings describes GERDA and MAJORANA DEMONSTRATOR capabilities and the general plan of LEGEND to reach the goal, while this second part is focused in the status of the first stage of LEGEND, LEGEND-200.

nucl-ex

Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of <3 counts/ROI-tonne-year, which is expected to scale down to <1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.

physics.ins-det

The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76Ge

Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The Majorana Collaboration is constructing the Majorana Demonstrator, a 40-kg modular germanium detector array, to search for the Neutrinoless double-beta decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge Neutrinoless double-beta decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the Majorana Demonstrator, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.

nucl-ex

Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. This paper will discuss the MAJORANA collaboration's solutions to some of these challenges.

physics.ins-det

MAJORANA Collaboration's Experience with Germanium Detectors

The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-type germanium detectors provide excellent energy resolution and a specially designed point contact geometry allows for sensitive pulse shape discrimination. This paper will summarize the experiences the \textsc{Majorana} collaboration made with enriched germanium detectors manufactured by ORTEC$^{\circledR}$. The process from production, to characterization and integration in \textsc{Majorana} mounting structure will be described. A summary of the performance of all enriched germanium detectors will be given.

physics.ins-det