SearcharxivSearch

arXiv subjects

I. Kim

Publications and source records attributed to I. Kim.

At least 19 recordsLinked to original sources

The measurement of the $^{99}$Tc $\beta$-decay spectrum and its implications for the effective value of weak axial coupling

Measurements of $\beta$-spectral shapes is an important way to examine the effective value of the weak axial coupling $g_{\rm A}$. These stu\ dies focus specifically on forbidden non-unique $\beta^-$ transitions, as only in these cases is the spectral shape directly sensitive to th\ e ratio $g_{\rm A}/g_{\rm V}$. Here, the value of the weak vector coupling constant, $g_{\rm V}$, is fixed at 1.0 according to the Conserve\ d Vector Current (CVC) hypothesis. In previous studies for the fourth-forbidden non-unique $\beta^-$ decays of $^{113}$Cd [J.~Kostensalo \textit{et al.}, Phys. Lett. B 822, 136652 (2021)] and $^{115}$In [A.~F. Leder \textit{et al.}, Phys. Rev. Lett. 129, 232502 \ (2022) and L. Pagnanini \textit{et al.}, Phys. Rev. Lett. 133, 122501 (2024)] a quenched value was determined for the ratio $g_{\rm A}/g_{\rm V}$ using $g_{\rm V}=1.0$. A notable exception is the recent measurement and analysis of the second-forbidden non-unique $\ \beta$-decay transition in $^{99}$Tc, performed by M. Paulsen \textit{et al.}, Phys. Rev. C 110, 05503(2024). Where an enhanced ratio $g_{\\ rm A}/g_{\rm V}=1.526(92)$ was suggested. To resolve this apparently contradictory situation with the effective value of $g_{\rm A}$, we hav\ e performed calculations based on the nuclear shell model (NSM) Hamiltonians glekpn, jj45pnb, and the MQPM approach with a careful considera\ tion of the small relativistic vector nuclear matrix element (sNME). The theoretical spectra were compared to the $^{99}$Tc $\beta$-decay sp\ ectrum by using the 4$\pi$ gold absorber with a Metallic Magnetic Calorimeter (MMC). In all cases, we found that the data matches well with \ reduced $g_{\rm A}$/$g_{\rm V}$ values of 1.0--1.2. Our result contradicts the previously reported measurement for $^{99}$Tc and instead sup\ ports a quenched axial coupling as reported for other isotopes.

nucl-ex

The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance

Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($\beta\beta(0\nu)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $\beta\beta(0\nu)$ search. This enabled it to achieve an ultimate half-life limit on $\beta\beta(0\nu)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.

physics.ins-det

High-Precision Excited-State Nuclear Recoil Spectroscopy with Superconducting Sensors

Superconducting sensors doped with rare isotopes have recently demonstrated powerful sensing performance for sub-keV radiation from nuclear decay. Here, we report the first high-resolution recoil spectroscopy of a single, selected nuclear state using superconducting tunnel junction (STJ) sensors. The STJ sensors were used to measure the eV-scale nuclear recoils produced in $^7$Be electron capture decay in coincidence with a 478 keV $\gamma$-ray emitted in decays to the lowest-lying excited nuclear state in $^7$Li. Details of the Doppler broadened recoil spectrum depend on the slow-down dynamics of the recoil ion. The measured spectral broadening is compared to empirical stopping power models as well as modern molecular dynamics simulations at low energy. The results have implications in several areas from nuclear structure and stopping powers at eV-scale energies to direct searches for dark matter, neutrino mass measurements, and other physics beyond the standard model.

physics.ins-det

Final Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

$^{76}$Ge can $\beta\beta$ decay into three possible excited states of $^{76}$Se, with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The MAJORANA DEMONSTRATOR was designed to study $\beta\beta$ decay of $^{76}$Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the DEMONSTRATOR sets the strongest half-life limits to date for all six transition modes. For $2\nu\beta\beta$ to the $0^+_1$ state of $^{76}$Se, this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of $T_{1/2}>1.5\times10^{24}$ y (90% CL).

nucl-ex

Athermal phonon collection efficiency in diamond crystals for low mass dark matter detection

We explored the efficacy of lab-grown diamonds as potential target materials for the direct detection of sub-GeV dark matter~(DM) using metallic magnetic calorimeters~(MMCs). Diamond, with its excellent phononic properties and the low atomic mass of the constituent carbon, can play a crucial role in detecting low-mass dark matter particles. The relatively long electron-hole pair lifetime inside the crystal may provide discrimination power between the DM-induced nuclear recoil events and the background-induced electron recoil events. Utilizing the the fast response times of the MMCs and their unique geometric versatility, we deployed a novel methodology for quantifying phonon dynamics inside diamond crystals. We demonstrated that lab-grown diamond crystals fabricated via the chemical vapor deposition~(CVD) technique can satisfy the stringent quality requirements for sub-GeV dark matter searches. The high-quality polycrystalline CVD diamond showed a superior athermal phonon collection efficiency compared to that of the reference sapphire crystal, and achieved energy resolution 62.7~eV at the 8.05~keV copper fluorescence line. With this energy resolution, we explored the low-energy range below 100~eV and confirmed the existence of so-called low-energy excess~(LEE) reported by multiple cryogenic experiments.

physics.ins-det

An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation

The background index is an important quantity which is used in projecting and calculating the half-life sensitivity of neutrinoless double-beta decay ($0\nu\beta\beta$) experiments. A novel analysis framework is presented to calculate the background index using the specific activities, masses and simulated efficiencies of an experiment's components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a background index distribution from the specific activity, mass and efficiency distributions. This analysis method is applied to the MAJORANA DEMONSTRATOR, which deployed arrays of high-purity Ge detectors enriched in $^{76}$Ge to search for $0\nu\beta\beta$. The framework projects a mean background index of $\left[8.95 \pm 0.36\right] \times 10^{-4}$cts/(keV kg yr) from $^{232}$Th and $^{238}$U in the DEMONSTRATOR's components.

nucl-ex

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of $^7$Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. We present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

physics.ins-det

Majorana Demonstrator Data Release for AI/ML Applications

The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to liaobo77@ucsd.edu (A. Li).

cs.LG

Energy Calibration of Germanium Detectors for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0\nu\beta\beta$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

physics.ins-det

Constraints on the decay of $^{180m}$Ta

$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $\beta$ and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the MAJORANA DEMONSTRATOR, an experimental search for the neutrinoless double-beta decay of $^{76}$Ge using an array of high-purity germanium detectors, to search for the decay of $^{180m}$Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the $^{180m}$Ta half-life on the different decay channels. With new limits up to 1.5 x $10^{19}$ years, we improved existing limits by one to two orders of magnitude. This result is the most sensitive search for a single $\beta$ and electron capture decay ever achieved.

nucl-ex

Modeling Backgrounds for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment containing $\sim$30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and $\sim$14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the $0\nu\beta\beta$ Q-value, 15.7 $\pm$ 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

nucl-ex

Charge Trapping and Energy Performance of the MAJORANA DEMONSTRATOR

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay experiment deploying PPC detectors enriched in $^{76}$Ge, has led to several novel improvements in the analysis of PPC signals. In this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the MAJORANA DEMONSTRATOR by approximately 30% to around 2.4 keV FWHM at 2039 keV, the $^{76}$Ge $Q$-value. An alternative approach achieving similar resolution enhancement is also presented.

physics.ins-det

Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

physics.data-an

Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-$\beta$ Decay in $^{76}$Ge

The MAJORANA DEMONSTRATOR searched for neutrinoless double-$\beta$ decay ($0\nu\beta\beta$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a world-leading energy resolution of 2.52 keV FWHM at the 2039 keV $Q_{\beta\beta}$ (0.12\%), we set a half-life limit of $0\nu\beta\beta$ in $^{76}$Ge at $T_{1/2}>8.3\times10^{25}$ yr (90\% C.L.). This provides a range of upper limits on $m_{\beta\beta}$ of $(113-269)$ meV (90\% C.L.), depending on the choice of nuclear matrix elements.

nucl-ex

Exotic dark matter search with the Majorana Demonstrator

With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $\nu_s \rightarrow \nu_a$. We report new limits on fermionic dark matter absorption ($\chi + A \rightarrow \nu + A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($\chi + \chi + A \rightarrow \phi + A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1--100)-keV low energy region of a 37.5-kg y exposure collected by the Demonstrator between May 2016 and November 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.

hep-ex

Search for solar axions via axion-photon coupling with the Majorana Demonstrator

Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{a\gamma}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.

nucl-ex

Experimental study of 13C({\alpha},n)16O reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($\alpha,n)^{16}$O reactions induced by $\alpha$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $\gamma$-rays emitted from the excited $^{16}$O states that are populated when the incoming $\alpha$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($\alpha,n$)-reactions in future double-beta decay search efforts.

nucl-ex

Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the \MJD\ experiment. Using a 37.5 kg-yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the $e \rightarrow \nu_e \overline{\nu_e} \nu_e$ decay channel by more than an order of magnitude. We also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

nucl-ex