SearcharxivSearch

arXiv subjects

I. Knapova

Publications and source records attributed to I. Knapova.

5 recordsLinked to original sources

Improved $^{94}$Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA

We report high-resolution measurements of the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ cross section in the neutron energy range from a few eV up to about 250 keV, performed at the n_TOF facility (CERN), and of the $^{94}\mathrm{Mo}(\mathrm{n},\mathrm{tot})$ cross section up to 32 keV, measured at GELINA (JRC Geel). A combined R-matrix analysis of capture and transmission data yields significantly improved neutron-resonance parameters for $^{94}$Mo. A total of 186 resonances were observed in this analysis of which 127 reported here for the first time. The resulting Maxwellian-averaged cross section at stellar temperatures relevant to the slow neutron-capture process (s-process) is approximately 25% lower than previous evaluations and literature values. To assess the astrophysical impact of the revised cross section, we performed s-process nucleosynthesis calculations for low-mass asymptotic giant branch stars. Despite the substantial reduction in the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ rate, the final yields vary by only 3-4%. This demonstrates that the isotopic budget of $^{94}$Mo in AGB stars is primarily governed by the branching flow at $^{94}\mathrm{Nb}$ rather than by the neutron-capture destruction on $^{94}$Mo itself. The new cross section thus helps disentangle nuclear cross-section uncertainties from branching-flow effects in the s-process production of $^{94}$Mo.

nucl-ex

The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements

A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.

physics.ins-det

High accuracy, high resolution 235U(n,f) cross section from n_TOF (CERN) in the thermal to 10 keV energy range

The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy. A resonance analysis has been performed up to 200 eV, with the code SAMMY. The resulting fission kernels are compared with the ones extracted on the basis of the resonance parameters of the most recent major evaluated data libraries. A comparison of the n_TOF data with the evaluated cross sections is also performed from thermal to 10 keV neutron energy for the energy-averaged cross section in energy groups of suitably chosen width. A good agreement is found in average between the new results and the latest evaluated data files ENDF-B/VIII and JEFF-3.3, as well as with respect to the IAEA reference files. However, some discrepancies are still present in some specific energy regions. The new dataset here presented, characterized by unprecedented resolution and accuracy, can help improving the evaluations in the Resolved Resonance Region and up to 10 keV, and reduce the uncertainties that affect this region.

nucl-ex

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,\gamma$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,\gamma$) and $^{56}$Fe($n, \gamma$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.

physics.ins-det

Measurement of the 235U(n,f) cross section relative to the 6Li(n,t) and 10B(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF

The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10÷30 keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the evaluated cross section in the 9÷18 keV neutron energy range is indeed overestimated, both in the recent updates of ENDF/B-VIII.0 and of the IAEA reference data. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The new, high accuracy results here reported may lead to a reduction of the uncertainty in the 1÷100 keV neutron energy region. Finally, the present data provide additional confidence on the recently re-evaluated cross section integral between 7.8 and 11 eV.

nucl-ex