SearcharxivSearch

arXiv subjects

I. Ladarescu

Publications and source records attributed to I. Ladarescu.

At least 19 recordsLinked to original sources

Improved $^{94}$Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA

We report high-resolution measurements of the $^{94}\mathrm{Mo}(\mathrm{n},γ)^{95}\mathrm{Mo}$ cross section in the neutron energy range from a few eV up to about 250 keV, performed at the n_TOF facility (CERN), and of the $^{94}\mathrm{Mo}(\mathrm{n},\mathrm{tot})$ cross section up to 32 keV, measured at GELINA (JRC Geel). A combined R-matrix analysis of capture and transmission data yields significantly improved neutron-resonance parameters for $^{94}$Mo. A total of 186 resonances were observed in this analysis of which 127 reported here for the first time. The resulting Maxwellian-averaged cross section at stellar temperatures relevant to the slow neutron-capture process (s-process) is approximately 25% lower than previous evaluations and literature values. To assess the astrophysical impact of the revised cross section, we performed s-process nucleosynthesis calculations for low-mass asymptotic giant branch stars. Despite the substantial reduction in the $^{94}\mathrm{Mo}(\mathrm{n},γ)^{95}\mathrm{Mo}$ rate, the final yields vary by only 3-4%. This demonstrates that the isotopic budget of $^{94}$Mo in AGB stars is primarily governed by the branching flow at $^{94}\mathrm{Nb}$ rather than by the neutron-capture destruction on $^{94}$Mo itself. The new cross section thus helps disentangle nuclear cross-section uncertainties from branching-flow effects in the s-process production of $^{94}$Mo.

nucl-ex

Energy-differential measurement of the $^{\mathrm{nat}}$C(n,p) and $^{\mathrm{nat}}$C(n,d) reactions at the n_TOF facility at CERN

Energy-differential cross section of the $^{\mathrm{nat}}$C(n,p) and $^{\mathrm{nat}}$C(n,d) reactions was measured at the neutron time of flight facility n_TOF at CERN. The measurement was performed in the first experimental area (EAR1; flight path of 182.5 m). Two position-sensitive $ΔE$-$E$ silicon telescopes were used. Two naturally occurring carbon isotopes, $^{12}$C and $^{13}$C, contribute to the reactions on natural carbon, with the (n,p) reaction threshold at 13.7 MeV and the (n,d) threshold at 14.9 MeV (determined by the $^{12}$C isotope for both reactions). This paper provides the details of the analysis leading to the final results published previously as a Letter. The cross section results are reported up to 25 MeV. During the data analysis the population of the excited states in the daughter nuclei $^{11}$B, $^{12}$B, $^{13}$B had to be considered, requiring the adoption of the branching ratios and angular distributions of the emitted particles from an external source of information. TALYS-2.0 calculations were used as the main source and an in-depth analysis of the model-related uncertainties was performed. The n_TOF results are largely inconsistent with the major evaluation libraries. On the other hand, an unexpected agreement is found with TALYS-2.0 calculations. Specifically, the obtained cross section for the (n,p) reaction is significantly higher than in the available evaluations, fully supporting the earlier finding from an integral measurement at n_TOF.

nucl-ex

First $^{94}$Nb($n,γ$) Measurement: Constraining the Nucleosynthetic Origin of $^{94}$Mo in Presolar Grains

Isotopic measurements of presolar silicon carbide grains from dying stars have revealed a puzzling overabundance of $^{94}$Mo that stellar nucleosynthesis models have failed to reproduce for two decades. This discrepancy challenged our understanding of the slow neutron-capture process ($s$-process) that forges approximately half of the elements heavier than iron. The key uncertainty lies at $^{94}$Nb, a radiactive branching point where competition between neutron capture and beta decay governs the $^{94}$Mo production, yet the neutron-capture cross section had never been measured. Here we report the first experimental determination of the $^{94}$Nb(n,$γ$)$^{95}$Nb cross section important for Mo isotopic abundances. The measurement was enabled by a coordinated effort involving high-purity target preparation at Institute of Solid State and Materials Research (IFW) Dresden, radioactive sample production at the Institut Laue-Langevin (ILL) Grenoble, radiochemical characterization at Paul Scherrer Institute (PSI) Villigen, and the Time-of-Flight CERN n$\_$TOF facility using for the first time segmented total-energy detectors. Incorporation of the resulting Maxwellian-averaged cross section into fully coupled nucleosynthesis models of low-mass asymptotic giant branch (AGB) stars brings them into agreement with the presolar grain data. These results remove a major nuclear-physics input uncertainty at the $^{94}$Nb branching point and provide a firmer foundation for understanding the origin of $^{94}$Mo in the solar system.

nucl-ex

Measurement of the $^\text{nat}$C(n,p) and $^\text{nat}$C(n,d) reactions from n_TOF at CERN

The energy dependence of the cross section of the (n,p) and (n,d) reactions on $^\text{nat}$C has been studied for the first time at the n_TOF facility at CERN, from the particle detection threshold up to 25 MeV. The measurement was performed with two telescopes made of position-sensitive silicon $ΔE$-$E$ detectors, covering the angular range from 20° to 140°. A detector efficiency has been determined by means of Monte Carlo simulations of the experimental setup. Various assumptions on the angular distributions and branching ratios of the excited levels of the residual $^{11}$B, $^{12}$B, $^{13}$B nuclei were considered. In particular, theoretical calculations based on the TALYS-2.0 code were used and the systematic uncertainties in the analysis results were determined from the variations in these distributions. The n_TOF data on the (n,p) and (n,d) reaction on carbon are characterized by a higher accuracy and wider energy range than currently available in literature. A comparison with current evaluations from different libraries reveals a rather significant disagreement with the n_TOF results, while a remarkable agreement is observed with the prediction of TALYS-2.0 for this light element.

nucl-ex

Imaging neutrons with a position-sensitive monolithic CLYC detector

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $γ$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at simultaneously obtaining information about the spatial origin of \g-ray and neutron sources. We first investigated the performance of large 50$\times$50~mm$^{2}$ monolithic CLYC crystals coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95\% $^{6}$Li-enriched CLYC detectors coupled to an array of 8$\times$8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. Energy resolution ranging from 6-8\% for the $^{137}$Cs peak and a figure of merit of 3-4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to $γ$-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5~mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.

physics.ins-det

First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED

Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boron compounds used in clinical practice. Current treatment planning relies on unconventional estimates of boron tumor uptake derived from prior PET scans and thus, an online boron-uptake monitor would be highly convenient. This work presents the first pilot experiments carried out at ILL-Grenoble with the high-efficiency Compton camera i-TED, hereby aiming at demonstrating its applicability for BNCT dosimetry by introducing real-time measurement of the boron concentration and imaging capabilities of spatial dose distribution. In this experiment, we measured the $^{10}$B uptake of different cancer cells of tongue squamous cell carcinoma, malignant melanoma and glioblastoma treated with BPA (80~ppm of $^{10}$B). The samples were irradiated with the thermal neutron spectrum of ILL-Grenoble and the 478keV $γ$-rays from the $^{7}$Li de-excitation after the neutron-boron reaction were registered both with the Compton imager and the high-sensitivity FIPPS HPGe array. These series of measurements allowed us to demonstrate the imaging capabilities of the Compton imaging device for the 478 keV $γ$-rays of interest for dosimetry in BNCT, as well as to assess its sensitivity, which was found to be below 1 $μ$g of $^{10}$B.

physics.med-ph

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $γ$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$γ$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $γ$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

physics.ins-det

Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility

The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$γ$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.

nucl-ex

Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.

physics.ins-det

Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility

Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.

nucl-ex

New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements

Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).

nucl-ex

First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility

One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.

nucl-ex

Measurement of the $^{14}$N(n,p)$^{14}$C cross section at the CERN n_TOF facility from sub-thermal energy to 800 keV

Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. $^{10}$B(n,$α$)$^7$Li and $^{235}$U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809$\pm$0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the $^{14}$N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.

nucl-ex

Simultaneous Gamma-Neutron Vision device: a portable and versatile tool for nuclear inspections

GN-Vision is a novel dual $γ$-ray and neutron imaging system, which aims at simultaneously obtaining information about the spatial origin of $γ$-ray and neutron sources. The proposed device is based on two position sensitive detection planes and exploits the Compton imaging technique for the imaging of $γ$-rays. In addition, spatial distributions of slow- and thermal-neutron sources ($<$100 eV) are reconstructed by using a passive neutron pin-hole collimator attached to the first detection plane. The proposed gamma-neutron imaging device could be of prime interest for nuclear safety and security applications. The two main advantages of this imaging system are its high efficiency and portability, making it well suited for nuclear applications were compactness and real-time imaging is important. This work presents the working principle and conceptual design of the GN-Vision system based on Monte Carlo simulations and explores its simultaneous $γ$-ray and neutron detection and imaging capabilities for a realistic case of a security inspection where a $^{252}$Cf source is hidden in a neutron moderating container.

physics.ins-det

The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements

A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.

physics.ins-det

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.

nucl-ex

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.

physics.ins-det

Machine Learning aided 3D-position reconstruction in large LaCl$_{3}$ crystals

We investigate five different models to reconstruct the 3D $γ$-ray hit coordinates in five large \lacls monolithic crystals optically coupled to pixelated silicon photomultipliers. These scintillators have a base surface of 50 $\times$ 50 mm$^2$ and five different thicknesses, from 10 mm to 30 mm. Four of these models are analytical prescriptions and one is based on a Convolutional Neural Network. Average resolutions close to 1-2mm fwhm are obtained in the transverse crystal plane for crystal thicknesses between 10 mm and 20 mm using analytical models. For thicker crystals average resolutions of about 3-5~mm fwhm are obtained. Depth of interaction resolutions between 1mm and 4 mm are achieved depending on the distance of the interaction point to the photosensor surface. We propose a Machine Learning algorithm to correct for linearity distortions and pin-cushion effects. The latter allows one to keep a large field of view of about 70-80\% of the crystal surface, regardless of crystal thickness. This work is aimed at optimizing the performance of the so-called Total Energy Detector with Compton imaging capability (i-TED) for time-of-flight neutron capture cross-section measurements.

physics.ins-det