SearcharxivSearch

arXiv subjects

I. Levy

Publications and source records attributed to I. Levy.

16 recordsLinked to original sources

Input to the ESPPU: The LUXE Experiment

This document presents an overview of LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics. The scientific case, facility, and detector setup are presented together with an overview of the foreseen timeline and expected capital costs.

hep-ex

Validation and demonstration of the AEFC as a practical safeguards tool for inventory verification

The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) instrument designed to determine the residual fissile mass in irradiated fuel assemblies for safeguards verification purposes. This is done by actively interrogating an assembly with a neutron source and measuring the total (Singles) and correlated (Doubles) neutron count rates resulting from induced fissions in the irradiated nuclear fuel and relating those rates to the residual fissile mass using calibration curves. Comprehensive NDA measurements of the irradiated fuel inventory at Israeli Research Reactor 1 (IRR-1) were taken with the AEFC to validate a set of previously developed calibration curves. During the campaign, measurements were acquired of 32 standard fuel assemblies and three control assemblies in just nine days. This is a significant majority of the research reactor's irradiated fuel inventory and the largest data set gathered by the AEFC to date. Many of the fuel assemblies measured during the campaign had much shorter cooling times than those assemblies previously measured with the instrument. Calibration curves developed from previous AEFC deployments were used to determine the residual U-235 mass in the measured standard fuel assemblies. The results of the campaign demonstrated that the AEFC can be used to estimate the U-235 mass remaining in a large number of irradiated fuel assemblies with 1%-5% uncertainty in a reasonable amount of time despite operating in a high dose environment.

physics.ins-det

Excess of $^{236}$U in the northwest Mediterranean Sea

In this work, we present first $^{236}$U results in the northwestern Mediterranean. $^{236}$U is studied in a seawater column sampled at DYFAMED (Dynamics of Atmospheric Fluxes in the Mediterranean Sea) station (Ligurian Sea). The obtained $^{236}$U/$^{238}$U atom ratios in the dissolved phase, ranging from about $2\times10^{-9}$ at $100$ m depth to about $1.5\times10^{-9}$ at $2350$ m depth, indicate that anthropogenic $^{236}$U dominates the whole water column. The corresponding deep-water column inventory ($12.6$ ng/m$^2$ or $32.1\times10^{12}$ atoms/m$^2$) exceeds by a factor of $2.5$ the expected one for global fallout at similar latitudes ($5$ ng/m$^2$ or $13\times10^{12}$ atoms/m$^2$), evidencing the influence of local or regional $^{236}$U sources in the western Mediterranean basin. On the other hand, the input of $^{236}$U associated to Saharan dust outbreaks is evaluated. It is estimated an additional $^{236}$U annual deposition of about $0.2$ pg/m$^2$ based on the study of atmospheric particles collected in Monaco during different Saharan dust intrusions. The obtained results in the corresponding suspended solids collected at DYFAMED station indicate that about $64$% of that $^{236}$U stays in solution in seawater. Overall, this source accounts for about $0.1$% of the $^{236}$U inventory excess observed at DYFAMED station. The influence of the so-called Chernobyl fallout and the radioactive effluents produced by the different nuclear installations allocated to the Mediterranean basin, might explain the inventory gap, however, further studies are necessary to come to a conclusion about its origin.

physics.ao-ph

Novel Silicon and GaAs Sensors for Compact Sampling Calorimeters

Two samples of silicon pad sensors and two samples of GaAs sensors are studied in an electron beam with 5 GeV energy from the DESY-II test-beam facility. The sizes of the silicon and GaAs sensors are about 9$\times$9 cm$^2$ and 5$\times$8 cm$^2$, respectively. The thickness is 500 micrometer for both the silicon and GaAs sensors. The pad size is about 5$\times$5 mm$^2$. The sensors are foreseen to be used in a compact electromagnetic sampling calorimeter. The readout of the pads is done by metal traces connected to the pads and the front-end ASICs at the edges of the sensors. For the silicon sensors, copper traces on a Kapton foil are connected to the sensor pads with conducting glue. The pads of the GaAs sensors are connected to bond-pads via aluminium traces on the sensor substrate. The readout is based on a dedicated front-end ASIC, called FLAME. Pre-processing of the raw data and deconvolution is performed with FPGAs. The whole system is orchestrated by a Trigger Logic Unit. Results are shown for the signal-to-noise ratio, the homogeneity of the response, edge effects on pads, and for signals due to the readout traces.

physics.ins-det

Technical Design Report for the LUXE Experiment

This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.

hep-ex

Top-Quark Physics at the CLIC Electron-Positron Linear Collider

The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of ttH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.

hep-ex

Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.

physics.ins-det

Detector Technologies for CLIC

The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.

physics.ins-det

Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.

physics.ins-det

Higgs Physics at the CLIC Electron-Positron Linear Collider

The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.

hep-ex

Results from the October 2014 CERN test beam of LumiCal

A prototype of a luminometer, designed for a future e+e- collider detector, was tested in the CERN PS accelerator T9 testbeam. The objective of this test beam was to demonstrate a multi-plane operation, to study the development of the electromagnetic shower and to compare it with MC simulations.

physics.ins-det

Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II

Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are available in large sizes, are of low cost and, like diamond sensors, can be operated without cooling. Here we present results of an irradiation study done with sapphire sensors in a high intensity low energy electron beam. Then, a multichannel direction-sensitive sapphire detector stack is described. It comprises 8 sapphire plates of 1 cm^2 size and 525 micro m thickness, metallized on both sides, and apposed to form a stack. Each second metal layer is supplied with a bias voltage, and the layers in between are connected to charge-sensitive preamplifiers. The performance of the detector was studied in a 5 GeV electron beam. The charge collection efficiency measured as a function of the bias voltage rises with the voltage, reaching about 10 % at 950 V. The signal size obtained from electrons crossing the stack at this voltage is about 22000 e, where e is the unit charge. The signal size is measured as a function of the hit position, showing variations of up to 20 % in the direction perpendicular to the beam and to the electric field. The measurement of the signal size as a function of the coordinate parallel to the electric field confirms the prediction that mainly electrons contribute to the signal. Also evidence for the presence of a polarisation field was observed.

physics.ins-det

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

physics.ins-det

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

physics.ins-det

Advanced experimental applications for x-ray transmission gratings Spectroscopy using a novel grating fabrication method

A novel fabrication method for soft x-ray transmission grating and other optical elements is presented. The method uses Focused-Ion-Beam (FIB) technology to fabricate high-quality free standing grating bars on Transmission Electron Microscopy grids (TEM-grid). High quality transmission gratings are obtained with superb accuracy and versatility. Using these gratings and back-illuminated CCD camera, absolutely calibrated x-ray spectra can be acquired for soft x-ray source diagnostics in the 100-3000 eV spectral range. Double grating combinations of identical or different parameters are easily fabricated, allowing advanced one-shot application of transmission grating spectroscopy. These applications include spectroscopy with different spectral resolutions, bandwidths, dynamic ranges, and may serve for identification of high-order contribution, and spectral calibrations of various x-ray optical elements.

physics.optics

Luminometer for the future International Linear Collider - simulation and beam test results

LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter modules placed symmetrically on opposite sides of the interaction point. To meet these goals, the energy resolution of the calorimeter must be better than 1.5% at high energies. LumiCal has been designed as a 30-layer sampling calorimeter with tungsten as the passive material and silicon as the active material. Monte Carlo simulation using the Geant4 software framework has been used to identify design elements which adversely impact energy resolution and correct for them without loss of statistics. BeamCal, covering polar angles smaller than LumiCal, will serve for beam tuning, luminosity optimisation and high energy electron detection. Secondly, prototypes of the sensors and electronics for both detectors have been evaluated during beam tests, the results of which are also presented here.

physics.ins-det