Searcharxiv⌕ Search

arXiv subjects

I. Mandić

Publications and source records attributed to I. Mandić.

22 records · Page 2Linked to original sources

Comparison of 35 and 50 μm thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2

We report results from the testing of 35 μm thick Ultra-Fast Silicon Detectors (UFSD produced by Hamamatsu Photonics (HPK), Japan and the comparison of these new results to data reported before on 50 μm thick UFSD produced by HPK. The 35 μm thick sensors were irradiated with neutrons to fluences of 0, 1*10^14, 1*10^15, 3*10^15, 6*10^15 neq/cm^2. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source. The leakage current, capacitance, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -27C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. Within the fluence range measured, the advantage of the 35 μm thick UFSD in timing accuracy, bias voltage and power can be established.

physics.ins-det↗

Charge collection properties of irradiated depleted CMOS pixel test structures

Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$Ω$cm are presented. Measurements were made before and after irradiation with reactor neutrons up to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Two sets of devices were investigated: unthinned (700 $μ$m) with substrate biased through the implant on top and thinned (200 $μ$m) with processed and metallised back plane. Depleted depth was estimated with Edge-TCT and collected charge was measured with $^{90}$Sr source using an external amplifier with 25 ns shaping time. Depleted depth at given bias voltage decreased with increasing neutron fluence but it was still larger than 70 $μ$m at 250 V after the highest fluence. After irradiation much higher collected charge was measured with thinned detectors with processed back plane although the same depleted depth was observed with Edge-TCT. Most probable value of collected charge of over 5000 electrons was measured also after irradiation to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. This is sufficient to ensure successful operation of these detectors at the outer layer of the pixel detector in the ATLAS experiment at the upgraded HL-LHC.

physics.ins-det↗

Charge collection properties in an irradiated pixel sensor built in a thick-film HV-SOI process

Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiation. In this article we present results of an extensive irradiation hardness study with neutrons up to a fluence of 1x10e16 neq/cm2. Charge collection in a passive pixelated structure was measured by Edge Transient Current Technique (E-TCT). The evolution of the effective space charge concentration was found to be compliant with the acceptor removal model, with the minimum of the space charge concentration being reached after 5x10e14 neq/cm2. An investigation of the in-pixel uniformity of the detector response revealed parasitic charge collection by the epitaxial silicon layer characteristic for the SOI design. The results were backed by a numerical simulation of charge collection in an equivalent detector layout.

physics.ins-det↗

Gain and time resolution of 45 $μ$m thin Low Gain Avalanche Detectors before and after irradiation up to a fluence of $10^{15}$ n$_{eq}$/cm$^2$

Low Gain Avalanche Detectors (LGADs) are silicon sensors with a built-in charge multiplication layer providing a gain of typically 10 to 50. Due to the combination of high signal-to-noise ratio and short rise time, thin LGADs provide good time resolutions. LGADs with an active thickness of about 45 $μ$m were produced at CNM Barcelona. Their gains and time resolutions were studied in beam tests for two different multiplication layer implantation doses, as well as before and after irradiation with neutrons up to $10^{15}$ n$_{eq}$/cm$^2$. The gain showed the expected decrease at a fixed voltage for a lower initial implantation dose, as well as for a higher fluence due to effective acceptor removal in the multiplication layer. Time resolutions below 30 ps were obtained at the highest applied voltages for both implantation doses before irradiation. Also after an intermediate fluence of $3\times10^{14}$ n$_{eq}$/cm$^2$, similar values were measured since a higher applicable reverse bias voltage could recover most of the pre-irradiation gain. At $10^{15}$ n$_{eq}$/cm$^2$, the time resolution at the maximum applicable voltage of 620 V during the beam test was measured to be 57 ps since the voltage stability was not good enough to compensate for the gain layer loss. The time resolutions were found to follow approximately a universal function of gain for all implantation doses and fluences.

physics.ins-det↗